background image

Copyright Safewaze 2023

Page 7

 7.0  INSPECTION FREQUENCY

Type of Use

Application Examples

Conditions of Use

Inspection Frequency

Competent Person

Infrequent to Light

Rescue and Confined Space, 

Factory Maintenance

Good Storage Conditions, Indoor

or Infrequent Outdoor Use, Room

Temperature, Clean Environments

Annually

Moderate to Heavy

Transportation, Residential 

Construction, Utilities, Warehouse

Fair Storage Conditions, Indoor and

Extended Outdoor Use, All Temperatures,

Clean or Dusty Environments

Semi-Annually to Annually

Severe to Continuous

Commercial Construction, Oil and 

Gas, Mining

Harsh Storage Conditions, Prolonged

or Continuous Outdoor Use, All

Temperatures, Dirty Environment

Quarterly to Semi-Annually

TABLE 3 - INSPECTION SCHEDULE PER ANSI Z359.14-2021 

TABLE 4 - MATERIALS 

TABLE 5 - PERFORMANCE REQUIREMENTS PER ANSI Z359.14-2021

(CLASS 1 SRL) 

 9.0  SPECIFICATIONS

 8.0  PURPOSE

Self Retracting Lifelines are used as part of a PFAS.   Safewaze SRLs are designed to safely arrest the user in a fall from height, while minimizing forces  

associated with what can be an extremely violent event.   Safewaze SRLs are authorized for use with Horizontal Lifeline Systems but must NEVER be used  

as the lifeline constituent of an HLL System.  Class 1 SRLs are designed for overhead applications.  Class 2 SRLs are designed for both overhead and below 

Dorsal D-ring use.  Maximum allowable Free Fall for Class 1 SRLs is 2 ft.. 

 

1.  

Authorized Person:

 A person assigned by the employer to perform duties at a location where such person will be exposed to a fall hazard.

2.  

Rescuer: 

Person or persons other than the rescue subject acting to perform an assisted rescue by operation of a rescue system.

Either the Authorized Person¹ (User) or the Rescuer² must inspect this equipment prior to each use.  The Inspection table (Table 3), should be used to determine 

proper inspection frequency.  The Inspection Form (Page 18) describes proper inspection procedures.  The Competent Person should record inspection results in 

the Inspection Form and retain a copy for records. (NOTE: User is advised to make copies of the Inspection Form on (Page 18) of this manual prior to filling out 

the form for the first time).  Copies of the Inspection Form can be used for later Inspections.  Annual inspections by a Competent Person other than the user must 

be recorded in the Inspection Log (Page 19). 

NOTE:

 Special rescue measures may be required for a fall over an edge.

Latitude Pro SRL-P Minimum Breaking Strength

3,600 lbs. (1632.9 kg)

Working Temperature Range

-35°F (-37°C) to 130°F (54°C)

Average Arresting Force

≤ 1,350 lbs. (612.3 kg)

Maximum Arresting Force

≤ 1,800 lbs. (816.5 kg)

Maximum Arrest Distance

42 in. (106.6 cm)

SRLs documented in this instruction manual meet the following Arrest Force and Arrest Distance maximums when tested in accordance with  ANSI Z359.14-2021.  

These calculations are based upon overhead anchorage of the SRL.

HOUSING

Clear Resin

DRUM

Aluminum and Plastic

LIFELINE

Dyneema® Webbing

SWIVEL

Steel

FASTENERS

Aluminum / Steel / Stainless Steel

LOCKING PAWLS

Stainless Steel

MAIN SHAFT

Steel

SPRINGS

Stainless Steel

Содержание LATITUDE PRO SRL-P Series

Страница 1: ...This manual is intended to meet the manufacturer s instructions as required by ANSI Z359 14 2021 and should be used as part of an employee training program as required by OSHA SRL P Instruction Manual...

Страница 2: ...EST DISTANCE MIN REQ FALL CLEARANCE 8 10 11 0 SWING FALLS 11 12 0 FALL PROTECTION AND RESCUE PLAN 12 13 0 NORMAL OPERATIONS 12 14 0 COMPATIBILITY OF COMPONENTS 12 15 0 COMPATIBILITY OF CONNECTORS 12 1...

Страница 3: ...or both that may affect or interfere with the safe function of each other DO NOT alter equipment DO NOT misuse equipment User must have a written Rescue Plan and means at hand to implement it when us...

Страница 4: ...10 1 S 7 Dyneema Webbing 7X 05 Clear Resin 3 7 X X 018 5011 1 S 7 Dyneema Webbing 7X 05 Clear Resin 3 3 X X 018 5012 1 S 7 Dyneema Webbing 7X 05 Clear Resin 2 5 X X 018 5013 1 S 7 Dyneema Webbing 7X 0...

Страница 5: ...s 1 and 2 Class 1 Self retracting devices which shall be used only on overhead anchorages and shall be subjected to a maximum free fall of 2 feet 0 6 m or less in practical application Class 2 Self re...

Страница 6: ...Figure 2 Illustrates a Fall Clearance Calculation Fall Clearance FC is the total combined values of Free Fall FF Deceleration Distance DD and a Safety Factor SF Safety Factor calculations may differ...

Страница 7: ...on assigned by the employer to perform duties at a location where such person will be exposed to a fall hazard 2 Rescuer Person or persons other than the rescue subject acting to perform an assisted r...

Страница 8: ...pical Fall Clearance calculation based on the ANSI Z359 14 2021 prescribed Maximum Allowed Free Fall of 24 in and Maximum Allowed Arrest Distance of 42 in Fall Clearance calculations may vary dependen...

Страница 9: ...DISTANCE OF 42 Lateral Offset Distance Y In Feet 0 2 4 6 8 10 15 20 25 8 7 6 2 3 m 8 3 2 5 m 9 2 7 m 10 1 3 1 m 11 4 3 5 m 12 9 4 m 17 1 5 2 m 21 6 6 6 m 26 3 8 m 10 7 6 2 3 m 8 3 2 5 m 8 9 2 7 m 9 8...

Страница 10: ...ovides the Maximum Allowed Distance below the D ring a Latitude Pro SRL P may be used as well as the Actual Arrest Distance as tested for each unit Both are factored into the MRFC calculation NOTE Min...

Страница 11: ...d above the user s Dorsal D ring The X Axis represents lateral movement of the worker in relation to the SRL Example Latitude Pro SRL P Anchored Overhead This example represents the user anchored 5 Ov...

Страница 12: ...ECTORS HAVE ADDITIONAL REQUIREMENTS CONTACT SAFEWAZE WITH QUESTIONS Connectors are compatible with connecting elements when they have been designed to work together in such a way that their sizes and...

Страница 13: ...the effects of a fall must be removed from service immediately Equipment must then be serviced See Section 18 if applicable or disposed of See Section 19 16 0 USE 16 1 OPERATION 16 2 AFTER A FALL A f...

Страница 14: ...ch Swivels should be hanging on the curved portion of bracket 4 Slide the bar behind both loops of webbing at dorsal D ring Swing the bracket closed unti it locks into place 5 Check the locking functi...

Страница 15: ...emicals remove the SRL from service and wash with water and a mild soap solution Inspect the SRL using the Inspection Form on Page 18 before returning to service 18 0 MAINTENANCE SERVICE AND STORAGE 1...

Страница 16: ...orce 900 lbs 408 23 kg Max Arrest Distance 42 in 106 68 cm Actual Arrest Distance 23 in 58 42 cm Actual Arrest Distance 23 in 58 42 cm Use Below D ring Not permitted Use Below D ring 2 ft 61 m Max Fre...

Страница 17: ...14 OSHA 1910 140 OSHA 1910 66 020052 FIGURE 13 INSPECTION DIAGRAMS Webbing Housing Labeling Labeling Labeling Labeling Labeling Swivel Top Snaphook Labeling Cover Hook Body Hook Body Load Impact Indic...

Страница 18: ...ok Body Rivets Corrosion Pitting Nicks CONNECTORS PASS FAIL NOTE Termination Stitch Splice or Swage Cuts Fraying Broken Stitching Excessive Wear Cable Separating Bird Caging Entire Length Retracts Smo...

Страница 19: ...Copyright Safewaze 2023 Page 19 Date Inspection Items Noted Corrective Action Initials INSPECTION LOG...

Страница 20: ...Copyright Safewaze 2023 Page 20 Safewaze 225 Wilshire Ave SW Concord NC 28025 PHONE 1 800 230 0319 FAX 1 704 262 9051 WEB safewaze com EMAIL info safewaze com...

Отзывы: