background image

ATTENTION:

 Do not remove tag.  This unit must be inspected before each use.  

Any unit that has seen fall arrest forces must be removed from service.  

Avoid contact with sharp edges and abrasive surfaces.  Only use compatible 

connections.  Do not subject this unit to physical hazards that include thermal, 

electrical and chemical sources.  Must read, understand and follow all 

manufacturer’s instructions included with this unit at time of shipment.  

Failure to follow these and any other manufacturer’s instructions may result in 

serious injury or death.

01884b

FS-EX110 | Removable Bolt Anchor

BATCH:

 XXXX

MFG DATE: 

MM/YYYY

MATERIALS: 

Stainless steel; aluminum; zinc plated copper; 7x19 aircraft cable

WEIGHT CAPACITY: 

420 lbs

MINIMUM BREAKING STRENGTH:

 10,000 lbf / 44.5 kN

MEETS: 

OSHA 1910.66 & 1926.502; ANSI Z359.18 Type A

01884a

322 Industrial Court

Concord, NC 28025

P: (704) 262-7893

F: (704) 262-9051

www.safewaze.com

ATTENTION:

 Do not remove tag.  

This unit must be inspected before each use.  

Any unit that has seen fall arrest forces must be removed from service.  

Avoid contact with sharp edges and abrasive surfaces.  Only use compatible 

connections.  Do not subject this unit to physical hazards that include thermal, 

electrical and chemical sources.  Must read, understand and follow all 

manufacturer

’s instructions included with this unit at time of shipment.  

Failure to follow these and any other manufacturer

’s instructions may result in 

serious injury or death.

01884b

FS-EX1

10 | Removable Bolt 

Anchor

BA

TCH:

 XXXX

MFG DA

TE: 

MM/YYYY

MA

TERIALS: 

Stainless steel; aluminum; zinc plated copper; 7x19 aircraft cable

WEIGHT CAP

ACITY

420 lbs

MINIMUM BREAKING STRENGTH:

 10,000 lbf / 44.5 kN

MEETS: 

OSHA

 1910.66 & 1926.502; 

ANSI Z359.18 

Type 

A

01884a

322 I

ndustr

ial C

our

t

Conc

or

d, NC 28025

P: (704) 262-7893

F: (704) 262-9051

ww

w.saf

ew

az

e.c

om

TAP!!!  

DO NOT REMOVE 

WARNING LABEL!  

May be used as an anchor point for a leading edge restraint 
system.  See optional anchor points below for example. The 
use of two anchors is not required for leading edge restraint 
systems unless otherwise specified by the manufacturer.  

WORK SURFACE  

OPTIONAL 

(ANCHOR POINTS)  

WORK SURFACE  

(ANCHOR POINT)  

Concrete must be  3000-

psi or higher and  fully 

cured. Installation  loca-

tion to be approved  by 

a qualified person.  

MINIMUM CLEARANCE 3ft (1m)  

DECK/FLOOR/GROUND LEVEL  

W

ARNING!!! SWING F

ALLS M

AY OC

CUR 

WHEN 

THE 

W

ORKER IS NO

T DIREC

TL

Y UNDER ANCHOR POINT

.  

All products subjected to fall arresting forces should be removed  

from service immediately!  

DRILLING & INSTALLATION INSTRUCTIONS: 

1.

 Drill a 1” (25mm) diameter hole at least 4.5” (114mm) deep. The  

     drilled hole must be straight and perpendicular to the surface.  

     Make sure the hole is of uniform diameter and free of peaks and  

     valleys on the inner wall. 

2.

 Blow hole clean with compressed air. 

3.

 Always inspect the hole carefully when reusing a   

     

     previously drilled hole. 

4.

 When placing anchor, place your thumb inside the anchor loop  

     and your first two fingers around the trigger. Squeeze fingers and  

     thumb together till the trigger and spring fully compress. 

5.

 Insert unit at least 4” (101mm) deep into hole and release the  

     trigger. Do not force. 

6.

 Set the unit with a slight tug on the anchor loop. 

7.

 The stop sleeve must always be partially inserted into the hole.  

REMOVAL INSTRUCTIONS:  

1. 

When removing anchor, place your thumb inside the anchor loop          

     and your first two fingers around the trigger. Squeeze fingers and            

     thumb together till the trigger and spring fully compress. 

2. 

While squeezing the trigger pull the anchor out of the hole. 

3.

 If the anchor becomes stuck, insert a punch, screwdriver or other          

     object into the hole until it touches the top of the cleaning bushing. 

4.

 Lightly tap with a hammer making sure the tool is touching the top         

     of the cleaning bushing while squeezing the trigger (cleaning                   

     bushing should be easily visible at the edge of the hole). 

5.

 If tool was required to remove the anchor, inspect thoroughly for    

     damage after removal. If damage is found remove from service and         

     destroy immediately.  

*The user shall be equipped with 

a means of limiting  the maximum 

dynamic forces exerted on the 

user during the arrest of a fall to a 

maximum of 8 kN (1350-lbf). In the 

EU these forces must be limited to

6 kN (1350-lbf)

PERFORMANCE: 

Static Tensile Strength: 

10,000-lbf  (44kN)  

Maximum Capacity: 

One worker with  

max weight of 420-lbs (190kg) when used 

as a single point anchorage connector for  

personal fall arrest or restraint system

DIMENSIONS: 

Weight:

 1-lbs (453g) 

Length: 

13.75” (349mm) 

Diameter 

1” (25mm)  

REGULATORY COMPLIANCE:

  

ANSI Z359.18 Type A, ANSI Z359.7-2011 

OSHA 1926.502, OSHA 1910.66,                   

COMPONENT MATERIALS:  

Aluminum:

 Trigger 

Aircraft Cable: 

Main Cable, Activator Wire 

Polyurethane: 

Loop Cover 

Stainless Steel:

 Cone, Spoons, Stop Sleeve 

Zinc Plated Steel: 

Spring, Cleaning Bushing 

Zinc Plated Copper: 

Swage  

min from an

y edge  

10”  

drill

 1”

Ø (25mm) 

  10” 

90º

90º

PROPER LOADING

Good

Best

See Spoon Orientation

Good

See Spoon Orientation

*Best practice for spoon orientation

when loaded 90º to hole.

SPOON ORIENTATION

Best

Ok

Load

Load

=

=

1.5” (38mm)

   

Cleaning Bushing  

Cleaning Ferrule  

7” (178mm)

   

End Termination

   

Stop Sleeve 

   

Spring

 

                   

Swage

   

13.75” (349mm)

   

Heavy Duty Return Wire

   

Trigger  

Anchor Loop

   

3” (76mm)

2” (50.8mm)

   

Spoon   

Main Cable  