ATTENTION:
Do not remove tag. This unit must be inspected before each use.
Any unit that has seen fall arrest forces must be removed from service.
Avoid contact with sharp edges and abrasive surfaces. Only use compatible
connections. Do not subject this unit to physical hazards that include thermal,
electrical and chemical sources. Must read, understand and follow all
manufacturer’s instructions included with this unit at time of shipment.
Failure to follow these and any other manufacturer’s instructions may result in
serious injury or death.
01884b
FS-EX110 | Removable Bolt Anchor
BATCH:
XXXX
MFG DATE:
MM/YYYY
MATERIALS:
Stainless steel; aluminum; zinc plated copper; 7x19 aircraft cable
WEIGHT CAPACITY:
420 lbs
MINIMUM BREAKING STRENGTH:
10,000 lbf / 44.5 kN
MEETS:
OSHA 1910.66 & 1926.502; ANSI Z359.18 Type A
01884a
322 Industrial Court
Concord, NC 28025
P: (704) 262-7893
F: (704) 262-9051
www.safewaze.com
ATTENTION:
Do not remove tag.
This unit must be inspected before each use.
Any unit that has seen fall arrest forces must be removed from service.
Avoid contact with sharp edges and abrasive surfaces. Only use compatible
connections. Do not subject this unit to physical hazards that include thermal,
electrical and chemical sources. Must read, understand and follow all
manufacturer
’s instructions included with this unit at time of shipment.
Failure to follow these and any other manufacturer
’s instructions may result in
serious injury or death.
01884b
FS-EX1
10 | Removable Bolt
Anchor
BA
TCH:
XXXX
MFG DA
TE:
MM/YYYY
MA
TERIALS:
Stainless steel; aluminum; zinc plated copper; 7x19 aircraft cable
WEIGHT CAP
ACITY
:
420 lbs
MINIMUM BREAKING STRENGTH:
10,000 lbf / 44.5 kN
MEETS:
OSHA
1910.66 & 1926.502;
ANSI Z359.18
Type
A
01884a
322 I
ndustr
ial C
our
t
Conc
or
d, NC 28025
P: (704) 262-7893
F: (704) 262-9051
ww
w.saf
ew
az
e.c
om
TAP!!!
DO NOT REMOVE
WARNING LABEL!
May be used as an anchor point for a leading edge restraint
system. See optional anchor points below for example. The
use of two anchors is not required for leading edge restraint
systems unless otherwise specified by the manufacturer.
WORK SURFACE
OPTIONAL
(ANCHOR POINTS)
WORK SURFACE
(ANCHOR POINT)
Concrete must be 3000-
psi or higher and fully
cured. Installation loca-
tion to be approved by
a qualified person.
MINIMUM CLEARANCE 3ft (1m)
DECK/FLOOR/GROUND LEVEL
W
ARNING!!! SWING F
ALLS M
AY OC
CUR
WHEN
THE
W
ORKER IS NO
T DIREC
TL
Y UNDER ANCHOR POINT
.
All products subjected to fall arresting forces should be removed
from service immediately!
DRILLING & INSTALLATION INSTRUCTIONS:
1.
Drill a 1” (25mm) diameter hole at least 4.5” (114mm) deep. The
drilled hole must be straight and perpendicular to the surface.
Make sure the hole is of uniform diameter and free of peaks and
valleys on the inner wall.
2.
Blow hole clean with compressed air.
3.
Always inspect the hole carefully when reusing a
previously drilled hole.
4.
When placing anchor, place your thumb inside the anchor loop
and your first two fingers around the trigger. Squeeze fingers and
thumb together till the trigger and spring fully compress.
5.
Insert unit at least 4” (101mm) deep into hole and release the
trigger. Do not force.
6.
Set the unit with a slight tug on the anchor loop.
7.
The stop sleeve must always be partially inserted into the hole.
REMOVAL INSTRUCTIONS:
1.
When removing anchor, place your thumb inside the anchor loop
and your first two fingers around the trigger. Squeeze fingers and
thumb together till the trigger and spring fully compress.
2.
While squeezing the trigger pull the anchor out of the hole.
3.
If the anchor becomes stuck, insert a punch, screwdriver or other
object into the hole until it touches the top of the cleaning bushing.
4.
Lightly tap with a hammer making sure the tool is touching the top
of the cleaning bushing while squeezing the trigger (cleaning
bushing should be easily visible at the edge of the hole).
5.
If tool was required to remove the anchor, inspect thoroughly for
damage after removal. If damage is found remove from service and
destroy immediately.
*The user shall be equipped with
a means of limiting the maximum
dynamic forces exerted on the
user during the arrest of a fall to a
maximum of 8 kN (1350-lbf). In the
EU these forces must be limited to
6 kN (1350-lbf)
PERFORMANCE:
Static Tensile Strength:
10,000-lbf (44kN)
Maximum Capacity:
One worker with
max weight of 420-lbs (190kg) when used
as a single point anchorage connector for
personal fall arrest or restraint system
DIMENSIONS:
Weight:
1-lbs (453g)
Length:
13.75” (349mm)
Diameter
1” (25mm)
REGULATORY COMPLIANCE:
ANSI Z359.18 Type A, ANSI Z359.7-2011
OSHA 1926.502, OSHA 1910.66,
COMPONENT MATERIALS:
Aluminum:
Trigger
Aircraft Cable:
Main Cable, Activator Wire
Polyurethane:
Loop Cover
Stainless Steel:
Cone, Spoons, Stop Sleeve
Zinc Plated Steel:
Spring, Cleaning Bushing
Zinc Plated Copper:
Swage
min from an
y edge
10”
drill
1”
Ø (25mm)
10”
90º
90º
0º
PROPER LOADING
Good
Best
See Spoon Orientation
Good
See Spoon Orientation
*Best practice for spoon orientation
when loaded 90º to hole.
SPOON ORIENTATION
Best
Ok
Load
Load
=
=
1.5” (38mm)
Cleaning Bushing
Cleaning Ferrule
7” (178mm)
End Termination
Stop Sleeve
Spring
Swage
13.75” (349mm)
Heavy Duty Return Wire
Trigger
Anchor Loop
3” (76mm)
2” (50.8mm)
Spoon
Main Cable