background image

V1.0 2022 Copyright Safewaze

USER INSPECTION, MAINTENANCE AND STORAGE OF EQUIPMENT

MAINTENANCE AND STORAGE

Users of personal fall arrest systems shall at a minimum, comply with all manufacturer instructions regarding the inspection, 

maintenance and storage of the equipment.  The user’s organization shall retain the manufacturer’s instructions and make them 

readily available to all users.  See ANSI Z359.2, 

Minimum Requirements for a Comprehensive Managed Fall Protection Program,

 

regarding user inspection, maintenance and storage of equipment.  

1.  In addition to the inspection requirements set forth in the manufacturer’s instructions, the equipment shall be inspected  

          

     by the user before each use and additionally by a competent person, other than the user, at interval of no more than 

     one year for:          

•  Absence or illegibility of markings.

• 

Absence of any elements affecting the equipment form, fit or function.

•  Evidence of defects in, or damage to, hardware elements including cracks, sharp edges, deformation, corrosion, chemical 

attack, excessive soiling, abrasion, alteration, needed or excessive lubrication, excessive aging and excessive wear.   

2.  Inspection criteria for the equipment shall be set by the user’s organization.  Such criteria for the equipment shall equal   

      

     or exceed the criteria established by this standard or the manufacturer’s instructions, whichever is greater.    

1.  Maintenance and storage of equipment shall be conducted by the user’s organization in accordance with the 

     manufacturer’s instructions.  Unique issues, which may arise due to conditions of use, shall be addressed with the 

     manufacturer.    

3.  Equipment shall be stored in a manner as to preclude damage from environmental factors such as temperature, light,     

        

     UV, excessive moisture, oil, chemicals and their vapors or other degrading elements.    

2.  Equipment which is in need of, or scheduled for, maintenance shall be tagged as unusable and removed from service.    

3.  When inspection reveals defects in, damage to, or inadequate maintenance of equipment, the equipment shall be 

     permanently removed from service or undergo adequate corrective maintenance by the original equipment 

     manufacturer or their designate before return to service.   

4

3

Содержание 019-2008

Страница 1: ...ng Extender So Loop 2 D rings Z359 11 2021 1926 502 1910 140 ANSI 130 310 lbs OSHA up to 420 lbs 019 2022 12 D Ring Extender w So Loop Z359 11 2021 1926 502 1910 140 ANSI 130 310 lbs OSHA up to 420 lb...

Страница 2: ...ntents 1 0 INTRODUCTION 5 2 0 APPLICATION 5 3 0 APPLICABLE SAFETY STANDARDS 5 4 0 WORKER CLASSIFICATIONS 5 5 0 PURPOSE 5 6 0 LIMITATIONS REQUIREMENTS 6 7 7 0 COMPATIBILITY OF COMPONENTS 8 8 0 COMPATIB...

Страница 3: ...ll arrest Age and fitness seriously affect a worker s ability to withstand falls Pregnant women or minors must not use this equipment Failure to heed this warning may result in serious injury or death...

Страница 4: ...rness The lanyard parking attachment is generally located in the sternal area to help reduce tripping and entanglement hazards Loose ends of straps can get caught in machinery or cause accidental dise...

Страница 5: ...be used in conjunction with a yoke which incorporates a spreader element to keep the FBH shoulder straps separate Waist Rear The waist rear attachment shall be used solely for travel restraint The wa...

Страница 6: ...mation corrosion chemical attack excessive soiling abrasion alteration needed or excessive lubrication excessive aging and excessive wear 2 Inspection criteria for the equipment shall be set by the us...

Страница 7: ...by possession of a recognized degree certificate or professional standing or who by extensive knowledge training and experience has successfully demonstrated his ability to solve or resolve problems...

Страница 8: ...e system of at least 1 5 000 lbs 22 2 kN for non certified anchorages or 2 Two times the maximum arresting force for certified anchorages When more than one fall arrest system is attached to an anchor...

Страница 9: ...he Energy Absorbing Lanyard EAL or Self Retracting Lifeline SRL used as part of the complete Personal Fall Arrest System PFAS A 6 ft Length of Shock Absorbing Lanyard Original working length B 4 ft El...

Страница 10: ...AGEMENT 3 gate opens 2 gate presses against non complaint part 4 parts disengage 1 Non compliant part Using a connector that is undersized or irregular in shape 1 to connect a snap hook or carabiner c...

Страница 11: ...ces be difficult to detect In any environment the extender must be inspected prior to each use however a harsh chemical environment can necessitate more frequent inspections Care should be taken to in...

Страница 12: ...l overhead anchor point tie off SRL housing attachment to dorsal D ring and 100 tie off Follow the manufacturer s instructions supplied with each system component Figure 7 indicates examples of inappr...

Страница 13: ...to ensure that they are legible and present If any labeling is illegible or missing remove the extender from service Inspect the D ring Extender to include stitching and hardware Ensure no stitches a...

Страница 14: ...IGURE 9 INSPECTION DIAGRAMS 15 4 PRODUCT LIFE 15 5 DISPOSAL WARNING WARNING Consult your doctor if there is reason to doubt your fitness to safely absorb the shock from a fall arrest Age and fitness s...

Страница 15: ...V1 0 2022 Copyright Safewaze 13 FIGURE 10 LABEL EXAMPLES 16 0 LABELING...

Страница 16: ...ESSES Model Number Name of Inspector Harness Configuration Serial Number Description Signature Lot Number Date of Inspection Date of Manufacture In Service Date Company Manufacturer PT PT Yes No TB TB...

Страница 17: ...V1 0 2022 Copyright Safewaze Safewaze 225 Wilshire Ave SW Concord NC 28025 PHONE 1 800 230 0319 FAX 1 704 262 9051 WEB Safewaze com EMAIL info Safewaze com...

Отзывы: