V1.0 2022 Copyright Safewaze
1.0 INTRODUCTION
Thank you for purchasing a Safewaze D-ring Extender. This manual must be read and understood in its entirety, and used as part
of an employee training program as required by OSHA or any applicable state agency. This manual and any other instructional
material must be available to the user of the equipment. The user must understand how to safely and effectively use their D-ring
Extender, and all fall protection equipment used in conjunction with the extender.
The Safewaze D-ring Extender is a bodywear component of the user’s Personal Fall Arrest System (PFAS). Safewaze D-ring
Extenders are offered in a variety of configurations to ensure that the user can work safely and comfortably in any work
environment. These instructions will cover the proper installation and use of an extender. The extender is part of a complete
PFAS that requires a properly rated anchorage and connector, that in conjunction with an appropriate connecting device, meets
the fall protection requirement.
2.0 APPLICATION
3.0 APPLICABLE SAFETY STANDARDS
When used according to instructions, extenders included in this manual meet ANSI Z359.11-2021 and OSHA regulations for
fall protection. Applicable standards and regulations depend on the type of work being done, and may include state-specific
regulations. Refer to local, state, and federal (OSHA) requirements for additional information concerning the governing of
occupational safety regarding Personal Fall Arrest Systems (PFAS).
4.0 WORKER CLASSIFICATIONS
Understand the definitions of those who work in proximity of or may be
exposed to fall hazards.
Qualified Person:
“Qualified Person” means one who, by possession of a recognized degree, certificate, or professional
standing, or who by extensive knowledge, training, and experience, has successfully demonstrated his ability to solve or resolve
problems relating to the subject matter, the work, or the project.
Competent Person:
“Competent Person” means one who is capable of identifying existing and predictable hazards in the
surroundings or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has authorization to
take prompt corrective measures to eliminate them.
Authorized Person:
“Authorized Person” means a person approved or assigned by the employer to perform a specific type of
duty or duties or to be at a specific location or locations at the job site.
It is the responsibility of a Qualified or Competent person to supervise the job site and ensure safety
regulations are complied with.
5.0 PURPOSE
Purpose:
The Safewaze series of D-ring Extenders are designed to be used as part of a Personal Fall Arrest System (PFAS).
-
A competent person shall train users on this equipment in accordance with OSHA and ANSI.
-
Never exceed a free fall distance of 6 ft. A free fall of more than 6 ft could cause excessive
arrest forces that
could result in serious injury or death.
-
Safewaze D-ring Extenders have a maximum capacity of:
ANSI
310 lbs (140.6 kg) including tools, clothing, etc...,
OSHA
up to 420 lbs. (190.51 kg) including tools,
clothing, etc...
-
Anchorages for attachment of a Personal Fall Arrest System shall support a minimum of 5,000 lbs or be
designed with a safety factor of two by a Qualified Person.
-
All Safewaze D-ring Extenders must IMMEDIATELY be removed from
service if subjected to fall
arrest forces.
-
Safewaze D-ring Extenders shall be inspected by the end user prior to each usage and by a Competent
Person other than the user at least annually. These annual inspections shall be documented.
5