background image

5

 

This product is for a single user. Do not attach multiple users to this product.

 

The connecting system shall contain a personal energy absorber.

 

Do not attach to any other point on the TempLink 5000 other than the specified 

attachment point. 

 

Use of incompatible connectors may lead to forced roll out and unintentional 

disconnection. 

 

 

Always consult the connecting system manufacturer's instruction to ensure it is 

suitable for use with this equipment.

 

During use always allow for the required fall clearance, swing fall and hazards present 

in the work place.

Storage, Transport and Maintenance

6.1 

Storage and transport

This equipment shall be stored and transported in a cool, dry environment, away from any 
hazards and out of direct sunlight. 

6.2 

Maintenance

6.2.1  The TempLink 5000 Single Point Anchor is non serviceable. The equipment may remain 
in service until it fails an inspection or is involved in a fall.

 

Do not attempt to modify or disassemble this product.

6.3 

Cleaning

The TempLink 5000 may be cleaned by the end user periodically to increase service life. After 
cleaning, the product shall undergo the pre-use inspection. Clean with a rag and warm water 
to remove dirt and grit. A mild detergent may be used to remove grease or oils from the 
product.

 

Do not store this product when wet. Allow the product to dry and conduct a pre-use 

inspection prior to returning the item to service.

Inspection

7.1 

Before and After Use

The TempLink 5000 Single Point Anchor shall be inspected before and after each use by the 
user.

7.2 

Competent Person

A competent person shall inspect the product at least every 12 months.

7.3 

Procedure

7.3.1  Attachment point - inspect for damage, deformation, corrosion or signs of over loading.
7.3.2  Fall Indicators - inspect tabs are intact. 
7.3.3  Screw Surface - inspect for damage, deformation, corrosion, signs of over loading 
twisting buckling.
7.3.4  Energy Absorber - inspect the serpentines lay flat and inline with the product. Inspect 
the energy absorber is free of cracks, dirt, debris, defects, damage, deformation, corrosion, 
signs of over loading.
7.3.5  Markings - inspect all markings are present and legible. Figure  10.

Содержание TempLink 5000

Страница 1: ...structures as specified in the installation manual for each product All safety procedures must be complied with in accordance with the current safety code s of practice s for working at heights in your region Ensure safety at all times by being attached to suitable anchor points and approved safety equipment or approved scaffolding Installation is to be carried out by or under the supervision of a...

Страница 2: ...e fall clearance In Figure 2 A represents the deflection TempLink 5000 300mm Max B represents free fall energy absorber deployment as well as the estimated D ring side of the harness Refer the manufacturer s information SF represents the recommended safety factor of 1m FC represents the total allowable fall clearance For safe use FC shall always be greater than A B SF Figure 2 Figure 3 B A SF FC 3...

Страница 3: ...ing which has another connector attached 2 In a position that will apply load to the gate mechanism 3 By passing the connection through the attachment 4 Connecting a connector to another connector 5 Around a structure and back to the lifeline 6 To an attachment that will limit the function of the gate 7 To a location that will not load the connector as designed 4 2 Compatibility of Connections Con...

Страница 4: ...trength of the structure Structure shall be accordance with local building codes Steel purlins shall be a minimum of 150mmx1 5mm Timber rafters shall be minimum 90x35mm with 70x45mm battens MGP10 or F7 3 Remove the existing roof sheeting screws in the area where the anchor is to be installed 4 Place the anchor on the roof and install a minimum of 5x 14 gauge screws through the mounting holes in th...

Страница 5: ... Cleaning The TempLink 5000 may be cleaned by the end user periodically to increase service life After cleaning the product shall undergo the pre use inspection Clean with a rag and warm water to remove dirt and grit A mild detergent may be used to remove grease or oils from the product Do not store this product when wet Allow the product to dry and conduct a pre use inspection prior to returning ...

Страница 6: ... 3 2 Fall Indicators inspect tabs are intact Comments 7 3 3 Screw Surface inspect for damage deformation corrosion signs of over loading twisting buckling Comments 7 3 4 Energy Absorber inspect the serpentines lay flat and inline with the product Inspect the energy absorber is free of cracks dirt debris defects damage deformation corrosion signs of over loading Comments 7 3 5 Markings inspect all ...

Страница 7: ...rgy absorber and PPE TempLink 5000 Single person Fall Arrest Anchor Complies with AS NZS 5532 2013 and EN795 2012 Multi directional 360 degree use Always read instruction handbook prior to use Fixing of TempLink 5000 1 Remove five 5 existing roof screws along the timber batten or purlin line at the location for the anchor 2 Position the TempLink 5000 to line up with the existing roofing screw hole...

Страница 8: ...rees to making good any such defects by repairing the same or at the Company s option by replacement for a period of 1 one year from the date of shipment This limited warranty applies provided that a defects have arising solely from faulty materials or workmanship b the Products have not received maltreatment inattention or interference c the Products have been installed in accordance with the Com...