BEFORE BEGINNING INSTALLATION:
♦
CAREFULLY READ THE INSTRUCTIONS BEFORE BEGINNING THE INSTALLATION.
♦
CONSULT LOCAL BUILDING CODES to make sure the installation complies with standards. In-
stallation must comply with current local, state, and federal building, plumbing, and electrical
codes.
It is the responsibility of the installer or owner to determine code requirements prior to installa-
tion.
♦
CHECK ENTIRE UNIT FOR CONCEALED DAMAGE. If there is damage, DO NOT INSTALL! Ship-
ping damage must be reported to the carrier immediately. All damage must be discovered and
reported prior to installation in order to have it covered under the warranty!
♦
Examine all plumbing for damage before installation. If damage has occurred, call Safety Bath at
1-877-826-6666 for instructions. Alterations or modifications of the plumbing system could ex-
pose users to serious injury and will invalidate all warranty claims.
♦
To protect the unit during installation, use a section of the box, cut to size, and place in the bot-
tom of the bathtub. When possible, keep the box cover over the bathtub.
♦
Make sure the bathroom floor is level and strong enough to support the weight of the water-filled
bathtub (50 pounds/sq.ft.). If you are renovating, remove necessary wallboard to install framing
and plumbing. Make sure the walls are properly insulated and comply with the appropriate build-
ing code.
♦
DO NOT BUILD THE SURROUNDING STRUCTURE BEFORE RECEIVING YOUR SO-LO. Structure
measurements should be verified against the unit to ensure a proper fit.
Make absolutely certain that access panels and/or service openings are properly placed and that
all possible areas where service may be required are accessible.
♦
If your Safety Bath So-Lo is equipped with the Warm Air Massage hydrotherapy system, the sys-
tem’s blower has been pre-installed at the factory. An access panel has been installed in the
front panel of the tub to make servicing the blower motor easier. Safety Bath highly also recom-
mends cutting a minimum of 12" x 12" (30 cm x 30 cm) access panel in the floor to access water
supply shut-off valves, plumbing, etc.
♦
Connections should be made by licensed plumbers and electricians.
♦
If replacing an old bathtub, Safety Bath highly recommends cleaning old waste plumbing before
installing your new So-Lo. Debris can fall into the drain during bathtub removal, causing block-
ages in the drain.
♦
Safety Bath recommends leaving the bathtub’s door slightly ajar when not in use. This will help
extend the life of the door seal, and will provide years of trouble-free service.
Important!