7
PINBRAZING
11
1.
Connect the brazing gun (power and trigger) cable & ground device to the unit.
2.
Select brazing pins and ceramic rings to match the specifications of the bonding cable you
selected.
3.
Check that the pin holder and ring holder on the gun are the correct sizes for the brazing pins
and ceramic rings you selected. If the sizes are incorrect, the pin holder and ring holder can be
changed, se maintenance of S15 gun on page 12.
4.
Insert the brazing pin into the pin
holder. The rounded tip should be
facing away from the gun.
5.
Insert the ceramic ring into the ring
holder. The serrated edge should be
facing away from the gun.
6.
Press on/off button and select the right pin type by pressing the ”setting” button.
The unit will remember what setting was used last.
7.
Hold the gun firmly with both hands as shown and pull the trigger
just once. The electronic will by itself finish the brazing process.
8.
Hold the gun in place for 3-4 sec after the brazing while the
brazing cools down.
9.
Remove the gun
straight
backwards without pulling the trigger!
10.
After the brazing has cooled, knock the shank off the brazing
pin using a hammer.
The brazing is completed.
NOTE:
If the brazing is aborted too early
“ERROR”
will turn on.
The brazing should be redone for a good result.
The error lamp will turn off after 8 seconds.
Use a new ceramic ring for each new brazing.
The battery indicator “LOW BATT” flashes when the batteries are almost discharged.
When the “LOW BATT” is constantly lit the batteries are discharged and
no more brazings can be done. Charge the battery.
IMPORTANT
Содержание ECONECT SAFE 94350