12
from damaged by mouse or other rodents.
④
The type and specification of detectors and cables in each defense zone should be
labeled on construction drawings (The usage of each wire within a cable shall be
marked).
⑤
All construction drawings should be archived for facilitating maintenance of the
host system.
2.
2.
2.
2. System
System
System
System Installation
Installation
Installation
Installation and
and
and
and Debugging
Debugging
Debugging
Debugging
Installation of Alarm Host
— —
The alarm host shall be installed in a hidden position, and its external siren
shall not be covered with any materials to ensure an audible alarm sound.
— —
The alarm host has no explosion-proof function, which cannot be directly
installed in Class I, II or III hazardous locations (i.e. locations where ignitable
concentration of flammable, explosive vapor/gas, dust or fiber exists), otherwise, it
may cause any hazard.
——
The alarm host shall not be close to devices with high electromagnetic radiation
such as TV, air conditioner, computer and microwave oven to avoid influencing
receiving effect.
— —
To ensure reliable operation of the alarm host, DC12V7Ah battery is
recommended as backup power if power failure often occurs or power failure takes a
long time in some areas.
——
To get good receiving effect, please fully stretch out the receiving antenna.
VI.
VI.
VI.
VI. How
How
How
How to
to
to
to Add/Delete
Add/Delete
Add/Delete
Add/Delete Remote
Remote
Remote
Remote Controllers
Controllers
Controllers
Controllers and
and
and
and Detectors
Detectors
Detectors
Detectors
This alarm host adopts code matching technology to add detectors and remote
control. The host can learn codes with 5 remote controllers and 120 detectors. There
are 120 defense zones in total, among which defense zone 000 is a tamper zone