Install the Power Control Unit according to the following instructions.

INSTALLATION - STEP 2/6

Mount the Power Control Unit 

.

PCU5.1-U

Fixed 1-phase connection.
See pages 12-13.

PCU3-W

Perilex-connectors.
See pages 10-11.

PCU3

Fixed 3-phase connection.
See pages 8-9.

PCU5.1-P

3-pin plug.
See pages 14-15.

Содержание PCU3

Страница 1: ...INSTALLATION MANUAL SAFERA Siro R line stove guard Power control units PCU3 PCU3 W PCU5 1 U PCU5 1 P 20812 V4 5 0 ENG SIRO R LINE ...

Страница 2: ...r any damages or expenses caused by inappropriate installation Check that the Stove Guard is compatible with the cooker see section 1 1 If the network cable is damaged it must be replaced by the service personnel of the manufacturer or their representative to avoid hazards All electrical connections must be carried out by a qualified electrician ATTENTION If the appliance was stored in a cold spa ...

Страница 3: ...ocket with its own power supply Ⓓ Min 8 mm Min 5 mm 200 mm 1 2 KLIK 3 KLIK 4 5 Cooker width Installation Height Max 60 cm 45 75 cm 60 90 cm 60 75 cm Width Align the Sensor unit 15 mm with the centre of the cooktop Depth Align the sensor of Sensor unit white lens 100 mm with the centre of the cooktop INSTALLATION STEP 1 6 Mount the Sensor unit ...

Страница 4: ...he following instructions INSTALLATION STEP 2 6 Mount the Power Control Unit Ⓒ PCU5 1 U Fixed 1 phase connection See pages 12 13 PCU3 W Perilex connectors See pages 10 11 PCU3 Fixed 3 phase connection See pages 8 9 PCU5 1 P 3 pin plug See pages 14 15 ...

Страница 5: ...tall the power control unit Ⓒ so that it is not exposed to moisture Check that all cables can move freely ѧ ѧ HINT If you are replacing a cooker press the ad justment mode button for five seconds until you hear a signal Continue the installation according to step 3 6 OUT IN PE L N L PE N L L 230V 16A 400V 10A 230V 16A 400V 10A 230V 16A 400V 10A MAX MAX MAX L1 L2 L3 MICRO DISCONNECTION OFF IN 5 x 2...

Страница 6: ...o operate Install the power control unit Ⓒ so that it is not exposed to moisture Check that all cables can move freely OUT IN PE L N L PE N L L 230V 16A 400V 10A 230V 16A 400V 10A 230V 16A 400V 10A MAX MAX MAX L1 L2 L3 MICRO DISCONNECTION OFF 66 mm 146 mm 313 mm 700 mm Optional water sensor connection See chapter 4 280 mm 126 mm Remove the fuses to the cooker and oven Mount the power control unit ...

Страница 7: ...isture Check that all cables can move freely IN 3 x 4 mm2 OUT 3 x 4 mm2 180 mm 60 mm 130 mm Optional water sensor connection See chapter 4 Remove the fuses to the cooker and oven Mount the power control unit Ⓒ on the wall behind the cooker or into the cabinet next to the cooker Couple the protective earth first PE Couple the other wires Don t reconnect the power to the cooker yet Installation PCU5...

Страница 8: ...TENTION Install the power control unit Ⓒ so that it is not exposed to moisture Check that all cables can move freely OFF OUT IN PE L N L PE N L 230V MAX 25A MICRO DISCONNECTION PE L L N L L N 3 4 PE 5 6 7 2 1 9 Don t reconnect the power to the cooker yet Optional water sensor connection See chapter 4 Connect the stove with 3 pin plug 8 PCU5 1 P INSTALLATION 3 pin plug ѧ ѧ HINT If you are replacing...

Страница 9: ...wireless connection When the indicator light panels start blinking yellow green you need to calibrate the system Choose from the two options Check that the indicator light for normal activity blinks every five seconds OPTION 1 Cooker and oven are connected to the Power Control Unit Ⓒ 1 2 OPTION 2 Only cooktop is connected to the Power Control Unit Ⓒ Turn on the biggest cooker plate with maximum po...

Страница 10: ...EP 5 6 Adjust the alarm limit When you adjust the alarm limit the new alarm limit is indica ted as shown in the table on the right 3 ѥ ѥ WARNING Do not set the alarm limit higher than 9 during the installation If the alarm limit is set too high the app liance may fail to detect a hazardous situ ation in time ѧ ѧ HINT You may check the alarm limit by pressing the ad justment mode button twice Locat...

Страница 11: ...allation is not proceeding as expected You can re start the installation process anytime by pressing the adjustment mode button for five seconds until you hear the signal and continue from step 3 6 The sensor unit Ⓐ is not responding to any button and none of the indicator lights are lit Ensure that the power supply Ⓓ is connected correctly to the wall socket and that the socket has power None of ...

Страница 12: ...fter signing off the previous one Attach the plug Ⓖ of the leakage sensor to the Power Control Unit Ⓗ 2 If there is an extra sensor its plug Ⓖ is connected to the connector Ⓘ of the previous sensor 3 Check the operation of the furthest sensor Ⓕ by placing a damp paper to wel against it for 15 seconds When the water is detected the Sensor unit Ⓐ gives a sound signal the warning light for water leak...