9
8
ѥ
WARNING
Make sure that there is no power supply to
the cooker and the oven by removing their
fuses. Also ensure that the cooker is swit-
ched off.
OUT-wires are always energized when
the power control unit is connected to the
electrical network. If a wire is loose, it must
be properly covered.
If the element voltage of the cooker is 400
V, the fuse can only be maximum of 10 A. If
the element is 230 V, the fuse can only be
maximum of 16 A.
Do not install the power control onit to ex-
cessive heat: Operational ambient tempera-
ture is +5 … +40°C.
⚐
ATTENTION
Power control unit
Ⓒ
requires a neutral
wire to operate.
Install the power control unit
Ⓒ
so that it
is not exposed to moisture. Check that all
cables can move freely.
ѧ
HINT
If you are replacing a cooker, press the ad-
justment mode button
❼
for five seconds
until you hear a signal. Continue the
installation according to step 3/6.
OUT
IN
PE
L/N
L
PE
N
L
L
230V 16A
400V 10A
230V 16A
400V 10A
230V 16A
400V 10A
MAX
MAX
MAX
L1
L2
L3
MICRO DISCONNECTION
OFF
IN
5 x 2,5 mm
2
0,7 m
OUT
5 x 2,5 mm
2
1,3 m
180 mm
60 mm
130 mm
Optional
water sensor
connection.
See chapter 4.
Remove the fuses to the cooker and oven.
Mount the power control unit
Ⓒ
on the wall behind the cooker or into the cabinet
next to the cooker.
Couple the protective earth first (PE).
Couple the other wires.
Don’t reconnect the power to the cooker yet.
Installation
3
4
5
2
1
PCU3 - INSTALLATION
Fixed 3-phase connection.
Содержание PCU3
Страница 13: ...24 ...