4.1  Testing AUX-channles with home automation systems

1.  Make a factory reset for the sensor 

unit: while pressing and holding 

the adjustment mode button 

press first the OK-button 

 and 

then the child proof lock button 

. After a couple of seconds, the 

indicator light panels 

 should lit 

purple.

2.  While the indicator light panels 

 

are lit purple, test the AUX-chan-

nels:

•  To activate AUX1 (alarm), press and hold the child proof lock button 

•  To activate AUX2 (cooking on), press and hold the OK-button 

3.  When you have finished testing, press the adjustment mode button 

 and pair 

the sensor unit again with the PCU normally according to the installation manual.

5. Removing the Connection Hub or CTU 

from a Safera System

Connection Hub and CTU cannot be removed by normal means. The system’s oper-

ating principle is that once they are installed, their removal will always raise an error 

event. In a special case where removal is necessary, contact local Safera Support for 

instructions.

8

9

1
3

7

2
4

5 6

Содержание Connection Hub

Страница 1: ...1 20863_01 A User manual Safera Connection Hub for Safera Siro IN line and Siro R ...

Страница 2: ... galvanic connection between the Safera system and the automation system When the AUX outputs are active ON the optoisolator s output transistors will be held in conducting mode thus enabling current flow from IN to OUT This connection can be used exactly as a relay s contact however the direction and amount of the current flow must be controlled as specified below Maximum IN OUT voltage is 24 VDC...

Страница 3: ...ecurity System 3 24 VDC provided by the automation system Pull up recommended to provide 1mA absolute max 10mA Logic input of the automation system Signal ground of the automation system IN OUT SAFERA Example connection of one AUX output In this case the home automation system s logic input is pulled to ground potential when the AUX output signal is active Note that the maximum current pass in the...

Страница 4: ...reliable extinguish launch The Power Supply must be replaced One red blink The CTU service interval 5 to 10 years has been reached The CTU must be replaced Two red blinks Connection Hub has lost connection with the CTU The CTU has been removed or the cable is damaged Replace the CTU and or cable if necessary Three red blinks The CTU has been emptied because of a fire alarm The CTU must be replaced...

Страница 5: ...s and hold the child proof lock button To activate AUX2 cooking on press and hold the OK button 3 When you have finished testing press the adjustment mode button and pair the sensor unit again with the PCU normally according to the installation manual 5 Removing the Connection Hub or CTU from a Safera System Connection Hub and CTU cannot be removed by normal means The system s oper ating principle...

Отзывы: