18
0,1m²
>>1.5 m
>>1.5 m
>>1.5 m
SafeLine GL6 v.2.1.1 EN
To avoid GSM interference: Place the unit, the lift emergency
telephone and the GSM antenna at least 1500 mm apart.
Avoid GSM
interference
Trouble-
shooting
No LED’s are lit.
• Make sure that the supply voltage is: 230 VAC
LED 3 is continuously red.
• Make sure that the SIM card is correctly inserted.
• Check that the SIM card PIN code is deactivated or that the PIN
code is set to ”1234”, “0000” or ”1111”
• Make sure that the SIM card is activated and operational by
testing the card in a cellular phone.
The call is interrupted directly after being connected.
• Make sure the battery is properly charged. Check voltage with
the battery plug disconnected.
Call cannot be connected. Error message from telephone operator.
• To make a call, area code must always be used.
Interference/
poor sound
quality
• Bear in mind that the wiring between GL6 and the lift tele-
phone/ phone is basically a “standard” PSTN-line and can
therefore not be placed within the lift travelling cable together
with high voltage. *** (Risk of interference)***
• Always place the antenna in an upward position and at least
1500 mm distance from GL6.
• Place the antenna where the highest field intensity is obtained
according to the table on the unit.
• When a call is connected, try placing the antenna in different
places to find where the best receiving/sending position is.