background image

www.safeline-group.com

09.2020

© 2020 SafeLine and all the SafeLine products and 

accessories are copyrighted by law.

GL6 manual

GSM gateways

SafeLine GL6 v.2.1.1 EN

Innovation brought to you from Tyresö Sweden

Содержание GL6

Страница 1: ...www safeline group com 09 2020 2020SafeLineandalltheSafeLineproductsand accessoriesarecopyrightedbylaw GL6manual GSM gateways SafeLine GL6 v 2 1 1 EN Innovation brought to you from Tyres Sweden...

Страница 2: ...P code IP20 Output 12 VDC maximum output 120 mA continuous 500 mA max 10 min Output indicator intercom 12 VDC max 100 mA Line voltage 48 VDC USB USB mini 2 0 Interface board SL6 GSM BOARD Supports 2G...

Страница 3: ...diagram 6 Relay output 7 Intercom 8 Network services 9 Activating the SIM card 9 Indication LED 10 GSM field strength 11 Reset button 11 Configuration 12 Configuration with PC 12 SafeLine Pro 12 Oper...

Страница 4: ...rer accepts no liability arising from printing errors mistakes or changes Declaration of conformity Download The declaration of conformity at our website www safeline group com Safety Precautions Only...

Страница 5: ...e 7 RJ12 for telephone line 8 SMA antenna connector 9 Terminals C3 Lift Monitoring System LMS SMS Programmable input for LMS to send SMS messages to up to 3 different numbers 10 GND SafeLine GL6 is a...

Страница 6: ...D C B A 1 2 1 2 3 5 6 7 1 2 4 1 2 12 V 0 V 230 VAC L 230 VAC N GND SafeLine GL6 v 2 1 1 EN Wiring diagram Battery Battery Input Relay 1 NO NC Input intercom only NO button Indicator intercom Telephone...

Страница 7: ...Relay is active when battery test has failed 2 System failure Relay is active when GL6 has GSM network coverage Relay deactivates when GSM network is missing for more than 15 seconds or when mains po...

Страница 8: ...Use of intercom When an intercom call is generated the GL6 rings up to 16 times waiting for a phone that is connected to the GL6 to answer LED3 indicates when a ringing call expires and when the call...

Страница 9: ...ll be randomly generated by the SafeLine GSM unit and memorized This is a safety measure making sure the SIM card will only work with the selected SafeLine GSM unit To change the PIN again use the PUK...

Страница 10: ...us red Battery test failure LED 3 indicates the phone line s status Slowly flashing green GSM network OK Flashing green Call connection in progress Flashing two times green Connected handset is not hu...

Страница 11: ...3 times Start a battery test manually Press once Cancel battery test Press once Turn on when using battery power Reset Minimum signal strength for using GSM Interface GSM field strength If the reset...

Страница 12: ...site after installation The configuration software SafeLine Pro can be downloaded from www safeline group com Configuration SafeLine Pro Use the latest version of SafeLine Pro The software can be dow...

Страница 13: ...al input for monitoring Function Here you can set the input to different functions None Input 1 is not enabled default SMS Sends a text message when the input has reached the set value Type Sets the i...

Страница 14: ...r 4 Text message Here you can enter information and specify the destination of the text message Battery failure SMS If the battery test fails a text message is sent SMS destination you can enter up to...

Страница 15: ...o test alarms activated Battery failure simulates a battery test Mains power failure simulates a power failure LMS message simulates an operational alarm failure Functions LMS input lights green when...

Страница 16: ...ile Equipment Identity The IMEI is used by the GSM and UMTS mobile phones The IMEI is used by yhe GSM network to identify and authorize mobile phones and can thus stop the stolen mobile phones and mak...

Страница 17: ...minutes An SMS is sent to 3 destinations maximum and with a maximum of 128 characters External input 1 SMS There is an input for monitoring with the possibility to send SMS messages The input require...

Страница 18: ...being connected Make sure the battery is properly charged Check voltage with the battery plug disconnected Call cannot be connected Error message from telephone operator To make a call area code must...

Страница 19: ...conformity assessment procedure Module A used as described in Annex II Accordingly respective manufacturer has done the radio modules conformity assessment Standards applied Article of Directive 2014...

Страница 20: ...SafeLine Denmark Vallensb kvej 20A 2 th 2605 Br ndby Denmark Tel 45 44 91 32 72 info dk safeline se SafeLine Headquarters Antennv gen 10 135 48 Tyres Sweden Tel 46 0 8 447 79 32 info safeline se Supp...

Отзывы: