SAFE-T-ALERT 70-742 Скачать руководство пользователя страница 6

 

End of Life Signal – The Sensor has a 5 Year Service Life  

All 70 Series models include an End of Life (EOL) Signal indicating 
the sensor has reached the end of its service life and you must 
replace the alarm. The signal is the LED flashing RED RED 
GREEN GREEN with a beep every 25-30 seconds. The EOL Signal 
may be reset by pushing TEST / RESET button on the alarm. This 
will reset the EOL Signal for a period of 72 hours  (3 days) for a 
total of up to 30 days. After 30 days the signal cannot be reset and 
the alarm must be replaced. DO NOT DISCONNECT THE 
ALARM UNTIL YOU HAVE A REPLACEMENT ALARM 
AVAILABLE TO INSTALL. 

 

MODELS 

70-742, 70-742-MS, 70-742-R Kit,                                    

 

70-742-R-MS Kit 

POWER SUPPLY 

12 VDC                                   

 

NOMINAL CURRENT DRAW                       108 mA (1.6 Amps with Solenoid Valve) 

                                                                           

 

OPERATIONAL  TEMPERATURE 

-40

F to +150

o

 F     -40

o

 C to +66

o

 C 

 

RELATIVE HUMIDITY 

15% (+/- 5%)  to 95% (+/- 4%)

 

AUDIBLE OUTPUT 

85 dB @ 10 feet 

 

 

GAS ALARM TRIGGER 

< 25% of the LEL of Propane and Methane  

GAS LEVEL CONFIRMATION    

8 Second delay before alarm

 

 

CO ALARM TRIGGER  

4 -15 Minutes @ 400 ppm            

 

 

 

 

CASE DIMENSIONS 

6.5”W x 3.5”H x 1.38”D 

  

  

WARRANTY 

1 Year Limited  

 

TESTING LABORATORY 

Underwriters Laboratories 

STANDARD 

UL 1484, Fourth Edition 

UL 2034, Third Edition

 

 

 
 

LIMITED PRODUCTS WARRANTY 

MTI INDUSTRIES, INC

. warrants to the original retail purchaser that its 

products will be free from defects of material or workmanship for a period 
of  One  (1)  year  from  the  date  of  retail  purchase.  If  proven  to  have  been 
defective in original materials or workmanship and returned, delivery costs 
prepaid, MTI INDUSTRIES, INC. will replace this product free of charge. 

 

LIMITS OF WARRANTY

 

Replacement  is  your  exclusive  remedy  under  this  limited  warranty  or  any 
other  warranty  (including  any  implied  warranty  of  merchantability  for  a 
particular  purpose).    Any  and  all  implied  warranties  or  merchantability  or 
fitness for a particular purpose shall be limited to the warranty period from 
the  original  date  of  retail  purchase.    MTI  INDUSTRIES,  INC.,  its  dealers 
and distributors shall in no case be responsible or in any way liable for any 
incidental  or  consequential  damages  for  any  reason.  Some  states  do  not 
allow the limitation or exclusion of incidental or consequential damages, or 
allow  limitations  on  how  long  an  implied  warranty  lasts,  so  the  above 
limitations may not apply to  you.  This  warranty  gives  you specific rights, 
and you may also have other rights, which may vary, from state to state.  

 

PRODUCT NOT WARRANTED 

NOTE-

 

There are no user serviceable parts inside the case. Opening any 

SAFE-T-ALERT

TM

    product  for  any  reason  voids  the  warranty.

  This 

warranty does not cover damage or failure resulting from acts of God, abuse, 
misuse, neglect, or faulty installation

.  

 

 

WARRANTY RETURN PROCEDURES

  

 

It is MTI’s experience that a CO / Propane Gas Alarm is sounding for a 
reason. Call, ask your dealer to call, or e-mail our Customer Service 
Department (as listed below) to trouble shoot the situation. 
  

Customer Service Phone No. - 800-383-0269    

Fax  No. 847-546-9007 
E-mail [email protected]  
Web Site: www.mtiindustries.com  

 

If Customer Service determines that the unit is defective, a Replacement 
Authorization (RA) number will be issued.  

No product will be accepted 

for service or replacement without first obtaining a RA number. 

 

If authorized, return this product to: 
 

MTI Industries, Inc.  
Warranty Dept. RA # (

INSERT RA NUMBER HERE

31632 N. Ellis Drive Unit 301  
Volo, IL 60073   

NOTE:  Mark the RA number in the area shown on the outside 
of the box! 

NOTE:  

70-742 is the basic unit (Single-station) with no interconnect, no relay, and no 
solenoid. 
70-742-MS is the Multi-station unit with interconnect, no relay, and no 
solenoid. 
70-742-R Kit is the basic unit (Single-station) with no interconnect, with a 
relay, and with a solenoid. 
70-742-R-MS Kit is the Multi-station unit with interconnect, with a relay, and 
with a solenoid. 
 

OWNERS REPLACEMENT RECORD 

 

Replace this 

SAFE-T-ALERT

TM

 70 SERIES CO /  GAS 

propane alarm 

within 5 years, of the production date on the back of the alarm. 

 

Production Date ______________________ 

 

Replace Date   ______________________ 
 
Installer       ________________________ 
 

NOTE:

  The  replacement  date  indicates  the  date  beyond  which  the 

device may no longer detect accurately.   

 
 

© MTI INDUSTRIES 2009

 

 