M A N A G E M E N T S Y S T E M
45
Management Features
RS-232 Serial Port
RS-232 serial management port of the IDU provides Terminal management via connected PC or
other terminal device or modem. The terminal connected to the serial management port provides
the same management functionality as Telnet console (refer to paragraph
Telnet/ASCII Console
Command Interface
).
In order to interconnect the IDU and the Management Terminal directly through serial ports, a
straight through
modem cable is needed. The serial port of the Management Terminal should be
configured as 19200 8-1-N, no data flow control.
Modem
PC/Terminal
Modem
IDU
PC/Terminal
IDU
RS-232
RS-232
If using modems, the management terminal is connected with the IDU remotely through a
telephone line. In this case the modem, which is connected with the IDU should be set to
auto
answer
mode.
Ethernet port
Ethernet port of the CFM-LM IDU is intended as main source of management connectivity and
will provide the broadest range of management functionality:
•
Web management via integrated Web server in the management software;
•
SNMP management via integrated SNMP agent;
•
Telnet server and CLI interface;
Ethernet interface could be used to connect IDU:
−
To PC/Laptop to manage IDU,
−
To LAN to constantly monitor IDU,
−
To router or any other TCP/IP packet network termination unit to have IDU as part of
network for management information.
Telnet/ASCII Console Command Interface
Telnet/Command Line Interface functionality and command system are described in the CFM-LM
Indoor Unit Configuration Guides, please refer to
References
, page 58.