T E C H N I C A L D A T A
57
Power Supply
The power consumption of the single terminal (ODU+IDU) is from 20 to 24 W, depending on
IDU type and installed modules.
Each IDU supplies its own ODU.
The single terminal should be supplied with 20 – 60 VDC, either “+” or “-” pole can be grounded.
The grounding connector is located at the rear side of each IDU. SAF Tehnika offers 220 V – 48 V
power supply for the single IDU as the supplementary accessory.
Any other type of DC supply that complies the above mentioned requirements could be used.
Environmental Requirements
SAF Tehnika CFM-LM equipment fulfils subsets of ETS 300 019 standard as included in EN 300
198 radio standard:
•
Indoor Unit is Climatic Class 3.1E compliant (according to ETSI ETS 300 019-1-3) and
are intended to be operational in weather-protected locations (equipment rooms or
shelters), with:
•
Temperature from –5 to +40
0
C;
•
Humidity from 5% to 95%,
•
Solar radiation up to 700 W/m
2
;
•
Wind velocity up to 5 m/s (18 km/h).
•
Outdoor Unit is Climatic Class 4.1 compliant (according to ETSI ETS 300 019-1-4) and
can be used without performance degradation outdoors under the following conditions:
•
Temperature from –33 to +55
0
C;
•
Humidity from 15% to 100%;
•
Solar radiation up to 1200 W/m
2
;
•
Wind velocity up to 50 m/s (180 km/h).
The IDU has the
IP 20
degree of protection according to IEC 60529 standard.
The ODU has the
IP 67
degree of protection according to IEC 60529 standard.