![Saf-Fro PRESTOTIG 415DC Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/saf-fro/prestotig-415dc/prestotig-415dc_operators-manual_3275862003.webp)
English 1 English
Technical Specifications
NAME
INDEX
PRESTOTIG 315 DC
W000403580
PRESTOTIG 415 DC
W000403582
INPUT
Input Voltage
Input Power at Rated Output
EMC Class
Frequency
400V
15%
Three Phase
315DC
6.5kW @ 100% Duty Cycle (Stick)
A 50/60Hz
5.1kW @ 100% Duty Cycle (TIG)
8.8kW @ 60% Duty Cycle (Stick)
6.1kW @ 60% Duty Cycle (TIG)
9.8kW @ 40% Duty Cycle (Stick)
8.1kW @ 40% Duty Cycle (TIG)
415DC
10.8kW @ 100% Duty Cycle (Stick)
A 50/60Hz
7.6kW @ 100% Duty Cycle (TIG)
11.3kW @ 60% Duty Cycle (Stick)
9.0kW @ 60% Duty Cycle (TIG)
16.4kW @ 35% Duty Cycle (Stick)
11.9kW @ 35% Duty Cycle (TIG)
RATED OUTPUT AT 40°C
Duty Cycle
(Based on a 10 min. period)
Output Current
Output Voltage
315DC
100% (Stick)
200A
28.0Vdc
100% (TIG)
220A
18.8Vdc
60% (Stick)
250A
30Vdc
60% (TIG)
250A
20Vdc
40% (Stick)
270A
30.8Vdc
40% (TIG)
300A
22.0Vdc
415DC
100% (Stick)
280A
31.2Vdc
100% (TIG)
300A
22.0Vdc
60% (Stick)
300A
32Vdc
60% (TIG)
320A
22.8Vdc
35% (Stick)
400A
36.0Vdc
35% (TIG)
400A
26.0Vdc
OUTPUT RANGE
Welding Current Range
Maximum Open Circuit Voltage
315DC
5 – 270A (Stick) / 5 – 300A (TIG)
65Vdc (CE model)
415DC
5 – 400A
12Vdc (AUSTRALIA model)
RECOMMENDED INPUT CABLE AND FUSE SIZES
Fuse (delayed) or Circuit Breaker (“D”
characteristic) Size
Input Power Cable
315DC
20A 4x2.5mm
2
415DC
30A 4x4mm
2
PHYSICAL DIMENSIONS
Height
Width
Length
Weight
315DC
405mm 235mm
535mm
24kg
415DC
465mm 290mm
670mm
38kg
Operating Temperature Storage
Temperature
-10°C to +40°C
-25°C to +55°C