List of menu options
Options
Options
Value
00 Exit
point
--
01 2-step
restart
On/Off
02 4-step
restart
On/Off
10 Spot
welding
On/Off
11 Spot fixed time
On/Off
20 Bi-Level
On/Off
30 Foot
Pedal
On/Off
40 Arc start strenght 1/2/3/4/5/6
50* Torch control function
Off/Cur/Job
51* Limit max current
Off/[Ampere]
52* Limit min current
Off/[Ampere]
60* Green
Mode
ON/OFF
99 Reset to factory default
To change a setting push SEL, then rotate the encoder
(Output Current Knob) to modify the setting, and push
SEL again to confirm the new value.
Error Codes and troubleshoting.
If an error occurs, turn Off the machine, wait for a few
seconds, then turn ON again. If the error remains, a
maintenance is required. Please contact the nearest
technical service center or Lincoln Electric and report the
error code displayed on the meter of the Front Panel.
Error code table
01
Input out of range
LED is blinking
Indicates that an Input Voltage Overrange
protection is active; the Machine restarts
automatically when the Input Voltage returns
in the correct range.
06
Inverter voltage lock out
LEDs blink alternatively.
Indicates that an Internal Auxiliary Voltage
fault condition is detected.
To restore the machine:
Turn OFF then ON the Mains Switch to
restart the machine.
10
Fan fault
The cooling fan is blocked or faulty.
To restore the machine:
Turn OFF the Mains Switch then and
check if the fan is being blocked by
something that stops the blades.
WARNING
DO NOT OPEN THE MACHINE!
Perform the check through the air inlet
louvers placed in the machine rear side.
DO NOT INTRODUCE OBJECTS
INSIDE OF THE LOUVERS!
Danger of
electric shock.
Turn ON the Mains Switch to restart the
machine and make a short weld, in order
to verify that the fan is restarted.
If the fan remains inactive a maintenance
from a Service is necessary.
11
Water cooler fault
Cooler fluid is not correctly flowing through
the torch. See the water cooler instruction
manual for more details.