![Saf-Fro PRESTOTIG 415DC Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/saf-fro/prestotig-415dc/prestotig-415dc_operators-manual_3275862021.webp)
English
English
19
List of parameters and Factory stored programs
List of parameters and Factory Configuration program:
Parameter
Factory Configuration
(P99)
Selectable Value Range
Displayed
parameter
name
Displayed
value
Preflow
0.1s
0 - 5s (step 0.1s)
Current
selected
value (s)
Start Current
Lift TIG 2-step: 22A
Not adjustable
Current
selected
value (A)
Lift TIG 4-step: 100%
HF TIG 2-step: 100%
HF TIG 4-step: 100%
5 - 200%
Upslope
0.5s
0 - 5s (step 0.1s)
Current
selected
value (s)
Set Current
5A
5 - 270A (Stick) (315DC)
5 - 300A (TIG) (315DC)
5 - 400A (415DC)
Voltage at
output studs
Current
selected
value (A)
Duty Cycle
50%
10 - 90% (step 5%)
(f>300Hz Duty=50%
315DC)
(f>200Hz Duty=50%
415DC)
Current
selected
value (%)
Frequency (f)
0.1Hz
0.1 - 10Hz (step 0.1Hz)
10 - 300Hz (step 1Hz)
300 - 500Hz (step 10Hz)
Current
selected
value (Hz)
Background
30%
10 - 90% (step 1%)
Current
selected
value (%)
Downslope
0s
0 - 20s (step 0.1s)
Current
selected
value (s)
Crater
30%
5 - 100%
Current
selected
value (A)
Postflow
10s
0 - 30s (step 1s)
Current
selected
value (s)
Stick Welding: SOFT and CRISP programs
Parameter Features
Selectable Value Range
Displayed
parameter
name
Displayed
value
Soft Stick
Hot start, Anti-Sticking and Arc Force are
automatically adjusted by the machine
Set Current
With SOFT / CRISP Stick,
this is the unique
parameter adjustable by
the user.
Current
selected
value (A)
Crisp Stick
Hot start, Anti-Sticking and Arc Force are
automatically adjusted by the machine
Current
selected
value (A)