3.2. CALIBRATE THE POWER
WARNING
:
When starting up for the firs
step must be repeated
Step 1
: Turn the wire diameter switch to SETUP position and press the
Step 2
: Select the
CaL
parameter with the left
Step 3
: Press the OK button on the front panel. The display unit indicates
Step 4
: Remove the torch nozzle.
Step 5
: Cut the wire.
Step 6
: Place the piece in contact with the contact tube.
Step 7
: Press the trigger.
Step 8
: The display will indicate the value of L (cable
Step 9
: Display the value of R using the right
Step 10
: Exit Setup.
3.3. DYSPLAY AND USE
3.3.1. Synergic mode
The Current, Voltage and Thickness values listed for each wire feed speed setting are provided for information purposes only.
measurements under given operating conditions, such as position, length of the end
The units current/voltage displayed correspond to the average measured values, and they may differ from the theoretical values.
Led indicator for program mode:
OFF: pre-welding display of instructions
ON: Display of measurements (average values)
Flashing: Measurements during welding.
Selection of wire, diameter, gas, welding process
Select the type of wire, the wire diameter, the used welding gas and welding process by turning the appropriate switch.
Selection of the material will determine the available values for diameter, gas and processes.
If synergy does’nt exist, power source displays
Selection of welding mode, arc length and pre
Select welding mode 2T, 4T, spot, synergic and manual by using press button return (3). Arc length can be adjusted with left
welding display adjustement is performed with right encoder (8). The selection of pre
3.3.2. Manual mode
This is the disengaged mode of the welding machine. Adjustable parameters for it are
In this mode, only the wire speed value is displayed.
3.3.3. SETUP mode
Accessing the SETUP:
The SETUP screen can only be accessed when no welding is in progress, by setting the Wire Diameter selector on the
It consist in two pull-down menu :
'CYCLE
’
Setting for the cycle phases. Refer to paragraph 6.2 for details
‘
COnFIG
’
Power source configuration
Configuring the SETUP:
In SETUP position, select
CYCLE
or
COnFIG
Turn the
left-hand
encoder to scroll through the available parameters.
Turn the
right-hand
encoder to set their value.
No welding start. All the changes are saved on exiting the SETUP menu.
320C
CALIBRATE THE POWER SOURCE
When starting up for the first time, the calibration is an unavoidable step to achieve quality welding. If polarity is reversed, this
step must be repeated.
to SETUP position and press the OK button to access the
COnFIG
Setup
parameter with the left-hand encoder and select
On
with the right-hand encoder.
: Press the OK button on the front panel. The display unit indicates
triGEr
.
contact with the contact tube.
will indicate the value of L (cable inductance).
: Display the value of R using the right-hand encoder (cable resistance).
The Current, Voltage and Thickness values listed for each wire feed speed setting are provided for information purposes only.
measurements under given operating conditions, such as position, length of the end section (flat position welding, butt welding).
correspond to the average measured values, and they may differ from the theoretical values.
welding display of instructions.
ON: Display of measurements (average values).
Flashing: Measurements during welding.
gas, welding process
Select the type of wire, the wire diameter, the used welding gas and welding process by turning the appropriate switch.
Selection of the material will determine the available values for diameter, gas and processes.
ce displays
nOt
SYn
,
GAS
SYn
,
DIA
SYn
Or
PrO
SYn
.
Selection of welding mode, arc length and pre-welding display
Select welding mode 2T, 4T, spot, synergic and manual by using press button return (3). Arc length can be adjusted with left
welding display adjustement is performed with right encoder (8). The selection of pre-welding preset is performed with press button OK. (10)
This is the disengaged mode of the welding machine. Adjustable parameters for it are wire speed, arc voltage and fine setting.
mode, only the wire speed value is displayed.
The SETUP screen can only be accessed when no welding is in progress, by setting the Wire Diameter selector on the
. Refer to paragraph 6.2 for details
COnFIG
by
pressing the OK button.
encoder to scroll through the available parameters.
encoder to set their value.
No welding start. All the changes are saved on exiting the SETUP menu.
EN
9
/
28
unavoidable step to achieve quality welding. If polarity is reversed, this
Setup
screen.
The Current, Voltage and Thickness values listed for each wire feed speed setting are provided for information purposes only. They correspond to
section (flat position welding, butt welding).
correspond to the average measured values, and they may differ from the theoretical values.
Select the type of wire, the wire diameter, the used welding gas and welding process by turning the appropriate switch.
Select welding mode 2T, 4T, spot, synergic and manual by using press button return (3). Arc length can be adjusted with left encoder (7) and pre-
welding preset is performed with press button OK. (10)
e speed, arc voltage and fine setting.
The SETUP screen can only be accessed when no welding is in progress, by setting the Wire Diameter selector on the front panel to position 1.
Содержание DIGISTEEL III 320C
Страница 16: ...16 28 DIGISTEEL III 320C EN 320C DIGIPULS III 320C...
Страница 17: ...DIGISTEEL III 320C DIGIPULS III 320C Internal and inverter 320C EN 17 28...
Страница 18: ...18 28 Front and rear DIGISTEEL III 320C EN 320C DIGIPULS III 320C...
Страница 22: ...22 28 5 7 ELECTRICAL DIAGRAM EN DIGISTEEL III 320C DIGIPULS III 320C...