Saf-Fro DIGISTEEL III 320C Скачать руководство пользователя страница 17

 

 

DIGISTEEL

 

III

 

320C

 

/

 

DIGIPULS

 

III

 

320C

 

 

    Internal and inverter :  

 

 

320C 

 

EN  

17

 

/

 

28 

 

Содержание DIGISTEEL III 320C

Страница 1: ...II 320C EN SAFETY INSTRUCTIONS FOR OPERATION AND MA Cat n 8695 1259 Rev A Date 03 2016 DIGISTEEL III 320C DIGIPULS III 320C FOR OPERATION AND MAINTENANCE Contact http www airliquidewelding com DIGISTE...

Страница 2: ...EN Arc welding and plasma cutting may be dangerous for the operator and persons close to the work area Read the operating manual...

Страница 3: ...ONNECTION 2 8 SWITCH ON 3 INSTRUCTIONS FOR USE 3 1 FRONT PANEL FUNCTIONS 3 2 CALIBRATE THE POWER SOURCE 3 3 DYSPLAY AND USE 4 OPTIONS ACCESSORIES 5 MAINTENANCE 5 1 GENERAL 5 2 ROLLERS AND WIRE GUIDE 5...

Страница 4: ...ptions refer to the instructions supplied with the option WARNING The plastic handles are not intended for slinging the set Stability of the equipment is 1 2 DIGISTEEL III 320C ALLATION is a manual we...

Страница 5: ...onnection Protection index Insulation class Standard WARNING This power source cannot be used in falling rain or snow It may be stored outside but it is not designed for without protection during rain...

Страница 6: ...r serve que l imp dance de r seau public d alimentation basse tension au point de couplage commun soit inf rieure ce mat riel est conforme la CEI 61000 3 11 et la CEI 61000 3 12 et peut tre connect au...

Страница 7: ...ersion and recognized power 320C The following wires are used in reverse polarity SD ZN SAFDUAL ZN feeder unit 5 and ensure that it can not fall Insert the spool of wire on the axis Make sure that the...

Страница 8: ...gas wire diameter and type of welding wire 2 3 4 7 1 DIGISTEEL III 320C Left display Voltage Right display Current wire speed wire thickness 1 for selection of welding mode 2 welding mode Button canc...

Страница 9: ...ess the OK button to access the COnFIG Setup parameter with the left hand encoder and select On with the right hand encoder Press the OK button on the front panel The display unit indicates triGEr con...

Страница 10: ...ing display no Software update mode no Factory settings reset Pressing YeS will cause a reset of the parameters to factory defaults when exit SETUP menu List of accessible parameters in CYCLE menu Def...

Страница 11: ...ivate program management mode SETUP PGM put YES exit SETUP Set your program with commutators then long push on button OK Screen displays message as following DIGIPULS III 320C allows to lock program m...

Страница 12: ...ff welding Adjust arc voltage during welding and out off welding 3 TROLLEY II NEW VERSION R f W000383000 It enables to easily move the power source in a worshop environment DIGISTEEL III 320C welding...

Страница 13: ...ith watercooler option W000345075 PROMIG NG 441W 3 M W000345076 PROMIG NG 441W 4 M W000345077 PROMIG NG 441W 5 M W000274865 PROMIG NG 450W 3 M W000274866 PROMIG NG 450W 4 M W000274867 PROMIG NG 450W 5...

Страница 14: ...emove dust and metal particles accumulated between the magnetic circuits and the windings of the transformer Work must be performed using a plastic tip to avoid damage to the insultation of the windin...

Страница 15: ...onents REFERENCE DESIGNATION W000386033 FANS 24VDC 80X25 QTY 2 W000386036 FRONT PANEL DIGISTEEL III 320C W000386038 FRONT PANEL DIGIPULS III 320C W000386040 TRANSPARENT PLASTIC COVER W000386041 AUXILI...

Страница 16: ...16 28 DIGISTEEL III 320C EN 320C DIGIPULS III 320C...

Страница 17: ...DIGISTEEL III 320C DIGIPULS III 320C Internal and inverter 320C EN 17 28...

Страница 18: ...18 28 Front and rear DIGISTEEL III 320C EN 320C DIGIPULS III 320C...

Страница 19: ...TEEL III 320C DIGIPULS III 320C that can be directly purchased from your local provider REFERENCE DESIGNATION W000373703 DUST FILTER W000278018 LOT OF 2 SCREWS FOR ROLLER W000277338 ROLLER ADAPTOR GUI...

Страница 20: ...SSAGE E25 C Let the generator cool down The fault disappears by itself after several minutes Make sure that the inverter fan works DISPLAY OF THE MESSAGE E33 MEM This message indicates that the memory...

Страница 21: ...power supply phases OTHER Wire stuck in the molten pool or at the contact tube Optimise the arc extinction parameters PR spray and post retract message when turning the power on The TtriG message is...

Страница 22: ...22 28 5 7 ELECTRICAL DIAGRAM EN DIGISTEEL III 320C DIGIPULS III 320C...

Страница 23: ...source arc great reduction in spatter when welding carbon steels resulting in a very significant reduction in finishing costs It improves the appearance of the weld bead thanks to improved wetting of...

Страница 24: ...tortions at high welding currents in the typical globular welding range Reduce the amount of spatter compared to the globular mode reduce smoke emissions compared with the usual modes up to 25 less pr...

Страница 25: ...in the general Cycle submenu of the SETUP It enables starting the welding with slope enables weld bead finish with a decreasing level of welding Pulling the trigger the first time activates the pre ga...

Страница 26: ...all positions but has the disadvant causing more spatters DIGISTEEL III 320C gas and turns on the welding current Releasing the trigger causes the welding to stop slope and sequencer settings is disab...

Страница 27: ...or instance when welding thin sheet metal such this mechanism c SHORT ARC 0 6 mm 0 8 mm 1 mm ATAL 5 ATAL 5 ATAL 5 ARCAL 14 ARCAL 14 ARCAL 14 ARCAL 21 ARCAL 21 ARCAL 21 CO2 CO2 NOXALIC 12 NOXALIC 12 AR...

Страница 28: ...LSE 0 8 mm 1 mm ARCAL 14 ARCAL 14 ARCAL 21 ARCAL 21 NOXALIC 12 NOXALIC 12 ARCAL 121 ARCAL 121 ARCAL 12 ARCAL 12 ARGON ARGON ARGON PULSE 0 6 mm 0 6 mm ARGON ARGON ARGON ARGON NOTE For any other synergi...

Отзывы: