Precautions and warnings “after” the use of equipment
- Turn the equipment off while in not in use for a long time.
- Carry out the cleaning and disinfection after the use of the equipment, including in the first use.
- Do not change any part of the equipment. Do not disconnect the cable or other connections
unnecessarily.
- When observing the presence of irremovable stains, cracks or fissures on the light conductor and
ocular protection, provides the replacement of the damaged components.
- If the equipment has any abnormality, check if the problem is related to any item listed in the
topic of unforeseen events (failures, causes and solutions). If it is not possible to resolve the
problem, turn off the equipment, remove the power supply cable from the socket and contact your
representative (Alliage).
Precautions in case of alteration in the functioning of equipment
Precautions and warnings during “cleaning and disinfection” of the equipment
- When disinfecting the handpiece, remove the light conductor; use neutral soap or alcohol 70% vol. Never
use povidone iodine, glutaraldehyde or chlorinated products, which with time can produce superficial
attacks over the instrument’s body. Never soak the instrument in disinfection baths.
- The conductor must be clean and sterilized at 134ºC before being used in the next patient.
- Before cleaning the equipment, disconnect it from the electricity.
- Avoid spilling water or other liquids inside the equipment, what might cause short circuits.
- Do not use micro-abrasive material or scouring pad in cleaning, do not use organic solvents or detergents
that can contain solvents like ether, stain remover, etc.
In order to avoid environmental contamination or undue use of the Equipment after it has become
useless, it should be discarded in the suitable place (as per the local legislation of the country).
- Pay attention to the local legislation of the country for the conditions of installation and disposal
of residue.
Precautions to be adopted against foreseeable or uncommon risks, related to
the deactivation and abandoning of equipment
Precautions for the Reduction of the Environment Impact
Alliage S/A aims to achieve an environmental policy that encourages the environmentally conscious
supply of medical products that continuously minimize environmental impact and are more
environmentally friendly and human health friendly.
To keep a minimum impact on the environment, observe the following recommendations:
• After installation, forward the recyclable materials for the recycling process.
• During the life circle of the equipment, turn it off when it is not being used.
The biomedical waste comprises nonhigh material susceptible to cause disease or house pathogenic
organisms that must be stored in a yellow bag properly labeled with the symbol of biological
hazard, or stored in a container resistant to perforation, tight and even collection and incineration.
The packaging consists of cardboard, plastic and expanded polystyrene (EPS) which are
100% recyclable materials.
Dimensions:
Main unit: 0,250 X 0,190 X 0,070 / MASS: About: 0,825 Kg.
PRECAUTIONS, RESTRICTIONS AND WARNINGS