English
9
57
DISPLAY
Description
1.24.9.
Delete value = 0 data from EVA-DTS report
Quick Reading
1.24.10.
Prolongation of response waiting time from EVA-DTS data players
Extended Time-outs
1.25-8
Allows setting a delay between the end of beverage preparation and the display of the
"Remove cup" message to the user.
Such delay is necessary to allow a complete drainage of the liquid in the dispensing tubes.
Tube emptying time
1/8
1.26.
It allows displaying for a few seconds the selection counters (total and since last reset)
during the machine start-up phase.
Audit Msg. Enable
1.27.
selection of the capsule type used with the machine.
This allows some machine actions to be adjusted according to the peculiarities of each
capsule type.
Capsule Type
1.28.
Water compensation for beverages made from coffee beans and coffee capsules.
The exact quantity of water dispensed by each machine depends on both the construction
tolerances of each water circuit component (pump, flowmeter, tubes, etc.) and the type of capsules
used.
This menu allows you to set a correction "evening out" these differences so that the end result in the
cup is always the same even if the machine is different.
During manufacturing, the optimum values are calculated and stored for each vending machine.
If a FACTORY DEFAULT is carried out or the CPU board is replaced, you need to reset the
correct value by following the simple instructions here below:
• Set the water for the COFFEE beverage = 30
• Dispense 3 beverages, checking their weight and calculating the rounded-up mean value
• If the result obtained is higher or lower than 30, the excess/default value must be subtracted/added
from/to the value set by default
EXAMPLE:
BEVERAGE 1 SEQUENCE 000C
COFFEE WATER = 30
Coffee 1 = 32 g
Coffee 2 = 35 g
Coffee 3 = 28 g
Work out the mean:
32 + 35 +28 = 95 -> 95/3 = 31.6
In this case, 31.6 being the obtained value, the machine is dispensing more water than the set
amount, so you will need to subtract 2 from the value set in the CAPSULE COMPENSATION
menu
If the mean value obtained were 28, you should add 2 to the value set in the CAPSULE
COMPENSATION menu
Water compensation
1.28.1.
Allows you to select the water compensation for products made from coffee capsules
Capsules
1.28.2.
Allows you to select the water compensation for products made from coffee beans
Beans
1.29.
Allows selecting if the dispensing outlet should be lit during the brewing or the cup
dispensing phase
Lighting Type
Содержание Cristallo 600 EVO
Страница 32: ...English 6 32 Standard product configuration Cristallo 600 EVO T T T Version 5 instant products...
Страница 49: ...English 9 49 ITEM NO MENU ITEM 6 13 Enabled groups 6 14 Groups Visible only if complete menus are enabled...
Страница 109: ......
Страница 110: ......
Страница 111: ......
Страница 112: ...Cod 15004321 Ed 02...