background image

ELSA DASH/SPRINT 

10 

Sprint only: 

a)  Check  that  the  locking  catch 

moves freely without sticking and that 

the  orange  O-ring  is  clean  and  in 

good condition. 
b)  Fit  the  demand  valve  to  the 

hood,  check  that  the  locking  catch 

clicks into place. 
c) 

Fit the exhale valve and clip the 

valve cover into place. 

4.2  CLEANING FACEMASKS 

Caution: 
Ensure  visor  is  not  scratched  or 

contaminated  with  oil  or  grease 

while cleaning. 

 

1. 

Operate  the  locking  catch,  turn 

the  demand  valve  clockwise  and 

withdraw it from the facemask. 
2. 

Immerse  the  facemask  in  a 

solution  of 

TriGene

  and  clean 

warm water. 
3. 

Rinse  the  facemask  in  clean 

water,  paying  particular  attention  to 

the exhale valve. 
4. 

Shake excess moisture from the 

facemask  and  allow  to  dry  naturally 

away from sunlight and direct heat. 
5. 

Disinfect the faceseal and inner 

mask with a 

TriGene

 hygienic wipe. 

6. 

Use  an 

Exxene

  de-misting 

wipe to polish the visor. 
7. 

Check the demand valve locking 

catch  moves  freely  without  sticking 

and  that  the  orange  O-ring  is  clean 

and in good condition. 
8. 

Fit  the  demand  valve  to  the 

facemask.  Press  the  reset  button 

(First Breath DV only). 

4.3  CHANGING CYLINDERS 

1. 

Break  the  anti-tamper  tag  and 

carefully open the bag lid. 
2. 

Unwind  the  quick-fire  cord  from 

the  cylinder  valve  handwheel  and 

detach  the  quick-fire  cord  from  the 

handwheel. 
3. 

Open  bag  fully  and  check  that 

the cylinder valve is fully closed. 
4. 

Release  the  cylinder  retaining 

strap  and  withdraw  the  cylinder  from 

the bag. 

 

5. 

Undo  the  reducer  handwheel 

and  remove  the  reducer  from  the 

cylinder  valve.  Mark  the  cylinder  as 

empty and return for charging. 
6. 

Check  that  the  reducer  and  its 

black  O-ring  are  in  good  condition 

and  that  the  O-ring  is  free  from 

grease. 

Содержание ELSA Sprint

Страница 1: ...ELSA DASH SPRINT Compressed Air Escape Breathing Apparatus User Instructions Article No 1034931 Issue F 03 2003...

Страница 2: ...RINT 5 2 7 STORAGE BAG 5 2 8 QUALITY ATTRIBUTES 6 3 INSTRUCTIONS FOR USE 6 3 1 INITIAL CHECKS 6 3 2 DONNING 6 3 3 HOOD DASH SPRINT 7 3 4 FACEMASK SPRINT 8 4 AFTER USE CLEANING AND TESTING 9 4 1 CLEANI...

Страница 3: ...daily when issued to wearers or deployed in ready use lockers or monthly if held in stores ELSA Dash and Sprint are escape apparatus DO NOT use for other purposes such as fire fighting or cargo handl...

Страница 4: ...3 for 200 bar cylinders or 35 mg m 3 for 300 bar cylinders National regulations for compressed air breathing apparatus must be observed 1 2 APPARATUS SELECTION When selecting respiratory protective eq...

Страница 5: ...e Manuals there are no shelf life limitations 1 6 USE IN EXPLOSIVE OR FLAMMABLE ATMOSPHERES Anti static versions of ELSA apparatus are approved for use in explosive and flammable atmospheres Anti stat...

Страница 6: ...easily when the bag is opened provides an indication that the bag has been opened When the apparatus is first delivered tags are provided separately with instructions for fitting permitting the conten...

Страница 7: ...SKS SPRINT Sprint is available with PanaSeal or Vision 3 facemasks Both are moulded in non dermatitic material and can be supplied with five point elastic or Neoprene head harnesses PanaSeal Facemask...

Страница 8: ...ed closes the demand valve This permits the demand valve to be removed from the facepiece for testing or at the end of an escape Once reset the demand valve is opened by the wearer inhaling sharply 2...

Страница 9: ...pparatus is an ISO9001 BS 5750 Pt 1 approved Division of Scott Health and Safety Limited NOTIFIED BODY Inspec International Ltd No 0194 Upper Wingbury Courtyard Wingrave Aylesbury Buckinghamshire HP22...

Страница 10: ...open the valve Cautions Ensure that finger nails and rings do not snag or tear the neckseal Do not roll or fold the neckseal when donning the hood 3 3 HOOD DASH SPRINT 1 Pull out the hood insert hands...

Страница 11: ...rness over the head If a Neoprene head harness is fitted tighten the straps in sequence bottom side then top DO NOT OVER TIGHTEN as this distorts the faceseal causing leaks 3 Inhale sharply to activat...

Страница 12: ...od breathing hose and bag using a clean lint free cloth moistened in a solution of TriGene Article Numbers 2008247 for 1 litre or 2008248 for 5 litres and warm water 4 Allow the hood and bag to dry na...

Страница 13: ...unlight and direct heat 5 Disinfect the faceseal and inner mask with a TriGene hygienic wipe 6 Use an Exxene de misting wipe to polish the visor 7 Check the demand valve locking catch moves freely wit...

Страница 14: ...rd around the cylinder valve handwheel so that the handwheel turns anti clockwise when the cord is pulled 13 Close the bag lid and fit an anti tamper tag 4 4 BREATHING APPARATUS LOG Enter details of t...

Страница 15: ...is a mandatory requirement that all escape apparatus shall be checked at monthly intervals In addition apparatus issued to wearers should be checked when issued and daily thereafter Apparatus deploye...

Страница 16: ...that the red O ring on the elbow is in good condition Replace if worn damaged or contaminated with oil or grease 4 Check that the silencer filter is not clogged worn or damaged Replace if necessary 5...

Страница 17: ...panels of the hood 2 Push the top of the hood into the bag with the rear hood panel next to the cylinder until the exhale valve is just below the rim of the bag 3 Roll the neckseal under the hood so...

Страница 18: ...Sabre Breathing Apparatus Scott Health and Safety Limited Pimbo Road West Pimbo Skelmersdale Lancashire WN8 9RA United Kingdom Tel 44 0 1695 711711 Fax 44 0 1695 711775...

Отзывы: