GRQ3122 model.  In addition, switch positions 8 through 20 will default to front panel settings, until they
are assigned other stored presets.  All switch assignments for positions 2 through 7, and any new
assignments for positions 8 and above, will render the front panel controls inoperative, until switch
position #1 is chosen again.  For GRQ3121-S and GRQ3122-S models, which do not have front panel
controls, switch position #1 will be disallowed, and switch positions 8 through 20 will remain unassigned
until they are reprogrammed.

Note that initial contact closure switch assignments require the Remote Control software, but once
assigned, presets and memories can be loaded into the Graphi-Q2 simply by choosing the appropriate
switch position.  Momentary contact is all that is needed to load a new memory into the Graphi-Q2.

8.6.2.3.  Contact closure changes with multiple units

 In conditions where multiple Graphi-Qs are wired in parallel from a single contact-closure switch, ground
loop problems can easily arise. To maximize your chances for problem-free operation, make sure all your
audio connections are balanced (including downstream amplifier connections), and that your Graphi-Qs
are placed in the same equipment rack and derive power from the same circuit.

Instead of using a switch wired in parallel, you might consider linking multiple Graphi-Qs with the Link
Table (see section 8.3).  Links for all parameters can be made relative or absolute, and you can change
all units that are linked simply by using a contact closure switch wired to one of the units.  NOTE:  When
using contact closure switching to control multiple units, be sure to allow sufficient time to lapse after
a switch change to allow all affected units to update.  Multiple rapid switching may result in only partial
loading of changing parameter values in linked units.

8.6.3.  Off Line Editing

From the Graphi-Q2 Welcome Screen (

Section 8.1

) that appears upon launching the program, you may

click on the “Off-Line Edit/Demo” button instead of connecting to actual Graphi-Q.  This will open the
software and all of its features, and will look exactly the same as during connected operation, with one
exception:  the default mode of the Off-Line setup will display simulated signal levels on the on-screen
metering.  You can turn this simulated meter activity off by choosing Option/Turn off meter display from
the top of the Main Remote screen.

Aside from demonstrating the look, feel, and control options of the Remote Software, this feature also
allows you to program and/or edit a Graphi-Q preset off-line.  You can create a complete setup, save
it to a hard drive or disk, and load the preset into a Graphi-Q in another location or audio setup.  To do
this, simply choose “Save the current preset to a disk file” from the File menu at the top of the screen.
You will be able to name the file and choose its storage location.  Single files are designated with a “.grq”
suffix, and are identical to files saved from an on-line Graphi-Q (see 

Section 8.6.1.3

).  Of course this

means you may also load a file saved externally into the Off-Line Mode, edit the file, save under a
different name, and load into another Graphi-Q.

Note that all Graphi-Q files created Off-Line are treated as a GRQ3122 (or GRQ3122-S) created file, and
will obey the rules described in Section 8.6.1.3 when loaded into a GRQ3121 (or GRQ3121-S) unit.

8.7.  ASSIGNING NAMES TO GRAPHI-Q2S

You can assign any 8-character name to all of the Graphi-Qs connected to your computer.  You can do
this from either the Network Chain screen (see 

Section 8.1

), or by choosing Reference Name Edit at

the bottom of the Options Menu.  This latter action will open up a screen that will also display units, serial
numbers, and names, which can be edited.

All assigned unit names will be displayed at the top of the Curve Display field on the Remote Software
main screen.  If no name has been chosen, the unit’s serial number will be displayed.

Содержание GRAPHI-Q2

Страница 1: ...mpressor Limiter with controls for ratio threshold and gain attack release and knee adjustable with remote Digital Delay with up to 1 second delay adjustable in 20 microsecond increments Bypass dedica...

Страница 2: ...E MARKING We the Manufacturer SABINE INC 13301 NW US HIGHWAY 441 ALACHUA FLORIDA USA declare that the product EQUALIZER SABINE MODEL GRQ3100 Is in conformity with Council Directive 73 23 EEC and 89 33...

Страница 3: ...Y SOFTWARE 18 6 9 FRONT PANEL CONTROL OPTIONS 18 Section Seven GRQ2 Remote Software Installation 19 7 1 SYSTEM REQUIREMENTS AND RECOMMENDATIONS 19 7 2 CONNECTIONS 19 7 3 INSTALLING THE SOFTWARE 20 Sec...

Страница 4: ...but also offer an expanded range of adjustment and ease of storage and recall that are much more difficult to achieve with analog technology And with the Sabine FBX algorithm one of the most serious...

Страница 5: ...LESS FILTER DRIFT Analog circuits rely on components that vary as they age and or are subjected to different ambient temperatures This variation can in turn cause analog filters to drift from their or...

Страница 6: ...cut for 31 specific frequencies High Low Cut Filters Input signal gain reduction indicators Digital Delay up down controls EQ range Press up down buttons simulta neously to toggle EQ range between 6...

Страница 7: ...122 Front Panel G G G G GR R R R RQ3 Q3 Q3 Q3 Q3122 Bac 122 Bac 122 Bac 122 Bac 122 Back Panel k Panel k Panel k Panel k Panel G G G G GR R R R RQ3 Q3 Q3 Q3 Q3122 S Bac 122 S Bac 122 S Bac 122 S Bac 1...

Страница 8: ...8 Section Four Block Diagram Internal Signal Path SECTION FOUR BLOCK DIAGRAM INTERNAL SIGNAL PATH...

Страница 9: ...g console and the input to a power amplifier In this configuration the GRQ2 can provide all your system processing including delay and crossover A typical configuration will look like this This config...

Страница 10: ...label them differently When in doubt consult the manual of the console manufacturer 5 4 USE AT A MIXER INSERT POINT The Graphi Q2 may also be used at a mixer insert point either for a single input ch...

Страница 11: ...and delay settings can be unique on each output 5 6 WHAT NOT TO DO The Graphi Q2 should NOT be used in the following configurations 1 Do NOT plug a microphone directly into the Graphi Q2 back panel Th...

Страница 12: ...TROLS Please make note of the default front panel control protocols that apply when setting graphic EQ FBX filters compression delay and output level for the two outputs of the single input Graphi Q2...

Страница 13: ...phic EQ sliders For the LOW CUT FILTER the Graphi Q2 will attenuate frequencies at and below your knob setting with a slope of 12 dB per octave For the HIGH CUT FILTER frequencies at and above the kno...

Страница 14: ...tions thereof of a filter including graphic EQ filters parametric filters and FBX filters More specifically width is defined by determining the outer frequencies surrounding the filter center point th...

Страница 15: ...arespecifictoeachchannel of your sound system STEP ONE EQUIPMENT SETUP Set up your sound system and position all the speakers and microphones you anticipate using When possible avoid placing microphon...

Страница 16: ...back a second time and an earlier filter will notch more deeply Whenthishappens theoriginalLEDindicatingthisfrequencywillblink showingittobethemostrecently active filter Repeat this procedure until on...

Страница 17: ...for usingtheGraphi Q2RemoteControlSoftwareCompressor Limitercontrol 6 6 DIGITAL DELAY CONTROLS 6 6 1 Front Panel Control DIGITAL DELAY controls are located to the right of the COMPRESSOR controls You...

Страница 18: ...er settings choose Global Parameters F5 key from the MAIN MENU or Global fromwithintheFBX Parametricscreen Youmaychangeanyvaluewithintheindicatedranges and your new settings will be used as new defaul...

Страница 19: ...ted user to load settings No cost future proof upgrading Your Graphi Q2 can be updated via a simple connection to the Sabinewebsite www Sabine com wheneverfirmwareand orsoftwareupgradesareannounced Al...

Страница 20: ...led GRQRemote NOTE forupdatingsoftwareorre flashingfirmware seesection8 10 UpgradingGraphi Q2Firmware andSoftware TECH TIP PC can t find Graphi Q2 Try these tips if you are having difficulty con necti...

Страница 21: ...your computer you can set up two distinct networks of Graphi Qs each consisting of up to eight units NOTE one COM port chain cannot communicate directly to another only within its own chain Double cli...

Страница 22: ...for a description of the control protocols for GRQ functions 8 2 1 Graphic Equalizer Changing EQ slider settings can be accomplished in three ways 1 Click and drag the desired EQ slider with the mouse...

Страница 23: ...type a value or 3 Adjust the gain knob in the Compressor Limiter section of the Remote Software main screen Compressor Gain and Output Level Controls are redundant and will change together 8 2 5 FBX F...

Страница 24: ...obal Parameter Link Indicator Important Note on Equipment Power on Sequencing and Feedback Suppression The Graphi Q2 is similar to a computer in that it requires several seconds to boot up and become...

Страница 25: ...first dynamic FBX filter have been set or when Setup is turned off by clicking on the Cancel Setup button Fortwo channelsystems AutoSetup willpromptyoutoperformthesamesetupforthesecondchannel orexitto...

Страница 26: ...The A output is for the low frequency band and the B output is for the high frequency band GRQ3122 or GRQ3122 S These are 2x2 units When using the crossover use only the A channel input Engagingthecr...

Страница 27: ...channels will be the ratio applied to both signal paths as well Note that stereo compression is distinct from linked compressor settings See Section 8 3 2 5 CompressorLinkingOptionsforGRQ3122andGRQ31...

Страница 28: ...ass controls are located at the bottom of the main screen and are activated by clicking the appropriate bypass boxes Active front panel units will display the appropriate bypass status as well The Rem...

Страница 29: ...meters for ABSOLUTELY LINKED cells will be copied to the identical setting The first cell you choose for your ABSOLUTE LINK group will be the source value forcopying andwillbehighlightedwitharedcolor...

Страница 30: ...AlllinkingthatinvolvestheA channelforsuchunits will automatically be applied to the B channel as well 8 3 2 2 Bypass Linking Bypass ActivestatusforallparametersisNOTincludedunderthecontroloflinkedcell...

Страница 31: ...ort in the other screen 1 In the Link Table enter the letter S in the appropriate channel boxes and click Apply 2 IntheCompressor Limiterscreen youmaytoggletheboxbelowtheCLOSEbuttontoengageeither True...

Страница 32: ...6 to 12 dB or vice versa will also change the scale for all linked units graphic EQ settings For REL LINK all scales will not change when one unit s scale is altered Instead all changes made will be i...

Страница 33: ...f how controls are linked for a multiple unit Graphi Q2 system Simply select PRINT from within the link table If you are out in the field and not attached to a printer you can use the Off Line Edit De...

Страница 34: ...Control screens will display these manual adjustments but remote control will be disabled The Curve Display on your monitor will indicate Preset 1 Front Panel in Control 2 Any adjustments made manuall...

Страница 35: ...tputs mostoftheparametersettingscanonlybesettoidenticalvalues forbothoutputs Fortheseparameters thesettingforchannelAoftheGRQ3122 savedpresetwillalso be copied to the B output for the GRQ3121 destinat...

Страница 36: ...f Line Editing FromtheGraphi Q2WelcomeScreen Section8 1 thatappearsuponlaunchingtheprogram youmay click on the Off Line Edit Demo button instead of connecting to actual Graphi Q This will open the sof...

Страница 37: ...e Graphi Q should set passwords To do this open the PASSWORD screen from the Tool Bar at the top of the main screen The PASSWORD screen looks like this Click the EDIT PASSWORD box The three password b...

Страница 38: ...fortheGraphi Q2 You can determine your Graphi Q2 s current firmware version by one of two methods 1 For front panel models GRQ3121 or GRQ3122 the firmware version will flash briefly in the digital del...

Страница 39: ...If you re moving your sound system around and can t rebuild the room each time you move or if you re working in an environment where you ve done all you can to improve the acoustics here are a few rul...

Страница 40: ...mon examples would include audio hum induced by AC electrical current 50 or 60 Hz plus harmonic multiples of those frequencies or acoustical feedback that arises when amplified sound is directed back...

Страница 41: ...ers the more extreme the boost or cut the more ripple peaks or dips centered at the EQ slider frequencies there will be in the resultant system frequency response VARY LEVEL AND LOCATION If you re mak...

Страница 42: ...requencyspeakersinmovietheatersbyfeeding a sharp click through the system They moved the speakers until they could only hear a single sharp click coming from both speakers You can use this same method...

Страница 43: ...ine to form visibleinterferencepatterns In some places the wave crests and troughs are in phase so theycombinedtomakealarger wave Inotherplacesthecrests are out of phase so the crest of one wave sourc...

Страница 44: ...in every live sound system and they cannot be corrected with equalization Fortunately most comb filter problems can be reduced to a minimum by synchronizing the signals and reducing the amplitude of...

Страница 45: ...f the signals from the under balcony speakers arrive within 10 msec of the signals from the center cluster Therefore we should set the delay to 65 69 msec You can allow a little more reverberation for...

Страница 46: ...ffect to the second performer by placing the Graphi Q in the mixer s channel insert point and adding a 25 msec delay Certainly taking advantage of the Precedence Effect is not as obvious to the audien...

Страница 47: ...ften added to the entire audio mix both in live sound and recording to increase its perceived loudness Mix consistency For expressive instruments or vocals which may have a large dynamic range compres...

Страница 48: ...gain change at the input level for signal levels that rise above the threshold Acompressionratioof4 1iseffectivelyalimiter nomatterhowmuch loudertheinputrisesabovethethreshold theoutputlevelremainsun...

Страница 49: ...h the signal is compressed once the gain exceeds the threshold Attack is generally set to a very quick response and can be varied from 1 to 99 msec Release Release sets the speed with which the output...

Страница 50: ...catches all hits medium attack quick release gain makeup boosted slightly soft knee BASS GUITAR Bass players use a variety of tech niques often in the same song that can benefit from compression Comp...

Страница 51: ...aphi Qpatchedinan effects or auxiliary loop you will only catch the feedback in the effects loop and not the mixer input channel Or you may have usedupalltheavailableFBXfilters leavingnoadditionalfilt...

Страница 52: ...ROL DOESN T WORK SIGNAL LOSES GAIN GOING THROUGHGraphi Q2 PARAMETRIC FILTERS DO NOT LINK REMOTE SOFTWARE SCREEN DISTORTED LETTERS DO NOT FIT CORRECTLY The FBX filters will not set on single channel un...

Страница 53: ...l GRQ Remote RS 232 Re mote switching GRQ3122 S GRQ3121 S GRQRemote RS 232 Remoteswitch ing SAVE RECALL CONFIGURATIONS 20 user defined 1 factory default 1 most recent configuration power down save 1 f...

Страница 54: ...h the receiver is connected Consult the dealer or an experienced radio TV technician for help Canadian Compliance Statement This digital apparatus does not exceed the Class B limits for radio noise em...