background image

SM-610 Front & Back Panels

9

ACTIVE/BYPASS
In Active mode, the unit controls feedback automatically. The
two-color "BY" LED lights green when the unit is in Active mode
and lights red when in Bypass mode. Phantom power and the
mic preamp remain active in Bypass mode; only the FBX function
is bypassed.

12VDC ADAPTOR
The FBX external power supply (single unit power supply;
model #S-PSU1) is included with the unit. Use of any other
power supplies may cause permanent damage to the unit and
WILL VOID THE WARRANTY.

LOCK FIXED FILTERS
When the "LOCK FIXED" button is pressed, its LED will light to
indicate that the FBX is in "LOCK FIXED" mode.  "LOCK FIXED"
mode can be activated at any time after system setup and will
stay on until the button is pressed again and the LED turns off.

FILTER  ACTIVITY
When one of the unit’s filters is activated, the corresponding LED
lights.  A blinking LED indicates the filter that was most recently
activated.

RESET
Press until the LEDs stop flashing to reset or clear all filters.

MIC GAIN
Use this to control the microphone preamp level. Adjust it as high
as possible without lighting the SOLO's red CLIP LED.

MEMORY:
The FBX stores the positions and depths of the filters in nonvolatile internal memory when the unit is turned off or during a power
failure.  The unit will return all filters to their previous frequencies and depths when it is turned back on.

BYPASS MODE:

The SL-610 has a true power-off bypass. The signal is unaffected in bypass mode even if the unit is turned off. If the
unit is in active mode, no signal will pass if the power is off.

Placing the SM-610 in bypass mode only shuts down the FBX function; the microphone preamp still functions when the
unit is in bypass mode. The SM-610 will not pass signal if the power is off in either active or bypass mode.

RESETTING THE FILTERS:
The user must reset the FBX if the microphones or speakers are moved significantly. To reset the unit, press RESET until the LEDs
stop flashing.

POWER DOWN:
Place the unit in BYPASS MODE before removing power from the unit.

INPUT
The input accepts unbalanced TS (Tip/Sleeve) 1/4" phone plug,
balanced TRS  (Tip/Ring/Sleeve) 1/4" phone plug, or balanced
XLR-3 (PIN 2 high) plug.

OUTPUT
Use unbalanced TS 1/4" phone plug for unbalanced mixer line
inputs. Use balanced TRS 1/4" phone plug (tip high) for balanced
mixer line inputs.

FILTER WIDTH SWITCH
Switch to narrow 1/10-octave filters for music applications or to
wider 1/5-octave filters for spoken word applications. The change
takes effect only on power up. Selecting a new width has no effect
unless you power down and then power up again.

Содержание FBX SOLO SL-610

Страница 1: ...y even during the program Another is the FBX micro filters are precisely placed while EQ filters are fixed The difference FBX filters do not have to be as deep so there is more system gain The most important advantage is that FBX micro filters are ten times narrower than 31 band EQ filters FBX micro filters return up to 90 percent of the power removed by EQ filters Over the years engineers stopped...

Страница 2: ...oubling the cost of your microphones speakers and power amp probably would not improve your system s frequency response as much as replacing your EQ with an FBX for chasing feedback 100 Hz 15 00 13 13 11 25 9 375 7 500 5 625 3 750 1 875 0 0 dBV 1K 10K Look for this symbol for specific information on the SL 610 for mixer insert points Look for this symbol for specific information on the SM 610 for ...

Страница 3: ...dback occurs during the program For many applications the optimal setting is the one which gives maximum gain i e four FIXED and two DYNAMIC filters default setting However in some applications such as use of wireless microphones mobility is more important than maximum gain In this case you may wish to set three fixed and three dynamic filters The filters can be reconfigured easily from the factor...

Страница 4: ...nect the SM 610 s line level output to an input on your mixer or amp See page 10 of this manual for information on use with a guitar amplifier The SM 610 input accepts both standard 1 4 phone and XLR input connectors 4 SL 610 Configuration2 SL 610 Configuration4 SL 610 Configuration3 SM 610 Setup ...

Страница 5: ...inimum 9 Slowly raise the input channel level fader for the channel being set until feedback occurs The SL 610 should quickly remove the feedback The first FILTER LED will then blink to indicate a filter has been set 10 Keep raising the level slowly until all FIXED FILTERS and one dynamic filter is set Any uninitialized dynamic filters will be set later if feedback occurs during the program 11 Now...

Страница 6: ... its red CLIP LED Then adjust the SM 610 MIC GAIN control one click counter clockwise to insure a margin of safety before clipping If your mixer has an input gain control adjust it to match the clip level of the SOLO 8 Adjust the mixer s master output to a nominal level usually 0dB 9 Slowly raise the channel level fader for the channel being set until feedback occurs The SM 610 should quickly remo...

Страница 7: ...uildings Gating microphones greatly reduces the number of possible feedback points in the room and allows for more system gain The level that turns the noise gate on and off is called the threshold If the level coming into the gate is greater than the threshold the noise gate opens and the mic is turned on If it is less than the threshold the noise gate closes and the mic is turned off You can adj...

Страница 8: ...The SM 610 will not pass signal if the power is off in either active or bypass mode RESETTINGTHEFILTERS TheusermustresettheFBXifthemicrophonesorspeakersaremovedsignificantly Toresettheunit pressRESETuntiltheLEDs stop flashing POWERDOWN Place the unit in BYPASS MODE before removing power from the unit LOCK FIXED FILTERS When the LOCK FIXED button is pressed its LED will light to indicate that the F...

Страница 9: ...pths of the filters in nonvolatile internal memory when the unit is turned off or during a power failure The unit will return all filters to their previous frequencies and depths when it is turned back on BYPASSMODE The SL 610 has a true power off bypass The signal is unaffected in bypass mode even if the unit is turned off If the unit is in active mode no signal will pass if the power is off Plac...

Страница 10: ...to filter as the SOLO finds new feedback points This gives the user a visual confirmation that the unit is functioning properly Q Why would the FBX cause a noticeable hum A It may hum if the system is improperly grounded Check for bad grounds Q Why does my system sound thin and muffled A Place the SOLO in BYPASS MODE If the system still sounds thin your problem is probably with improper use of a g...

Страница 11: ... OSHA ANY EXPOSURE IN EXCESS OF THE ABOVE PERMISSIBLE LIMITS COULD RESULT IN HEARING LOSS EAR PLUGS OR PROTECTORS IN THE EAR CANALS OR OVER THE EARS MUST BE WORN WHEN OPERATING THIS DEVICE IN ORDER TO PREVENT A PERMANENT HEARING LOSS IF EXPOSURE IS IN EXCESS OF THE LIMITS AS SET FORTH ABOVE TO ENSURE AGAINST POTENTIALLY DANGEROUS EXPOSURE TO HIGH SOUND PRESSURE LEVELS IT IS RECOMMENDED THAT ALL PE...

Страница 12: ...urchaser Sabine s liability to the purchaser for damages from any cause whatsoever and regardless of the form of action including negligence is limited to the actual damages up to the greater of 500 00 or an amount equal to the purchase price of the product that caused the damage or that is the subject of or is directly related to the cause of action Such purchase price will be that in effect for ...

Отзывы: