background image

ENGINEERING SPECIFICATIONS

Filters
Six independent digital notch filters controlled automatically from
51Hz to 17,000Hz
Filter width: 1/10 octave, typical, or 1/5-oct. selectable
Filter depth: DSP controlled, variable to -50dB
Resolution: 1/20 octave or better
Time required to find and eliminate feedback: 0.4 seconds,
typical @ 1KHz
Total number of combined filters active: User selectable,
from 1 to 6
Number of Dynamic vs. Fixed filters: User selectable
Last configuration stored in memory

Input/output - SL610 ONLY
Input Impedance: 
Unbalanced 10K Ohms
Output Impedance: Unbalanced 10 Ohms nominal; Maximum
load 2K Ohms
Input/Output Maximum Signal Levels: Unba14dBV
peak at clip; 11dBV RMS
I/O Connectors: 1/4" TRS; tip=input, ring=output, sleeve=ground
Bypass:  True Power Off Bypass; Unbalanced to Unbalanced

Input/output - SM610 ONLY
Input: 
Combination 1/4" TRS & XLR-3 PIN 2 high Balanced
Input Impedance: 1 meg Ohm
Gain Range: 8 to 40dB
Maximum Input Level at lowest gain: +6dBV peak
48V phantom power jumper selectable (available on XLR input

only)
Output: 1/4"; tip high, sleeve ground
Output Impedance: Unbalanced 10 Ohms nominal; Maximum
load 2K Ohms
Output Level: Unba14dBV peak at clip nominal
Bypass:  Affects FBX function only; mic preamp stays on.
EIN: -105dBm @ 150 Ohms, 20Hz-17KHz or better

PERFORMANCE*
Frequency Response: 
<  +0.5dB, 20Hz to 17,000Hz
Signal to Noise Ratio: >85dB typical
Total Harmonic Distortion: <0.015% @ 1KHz @ any gain
setting
Dynamic Range: >92dB

POWER SUPPLY
8-20VDC @ 400 mA

MEMORY BATTERY LIFE
7 years, typical

DIMENSIONS
1-U height, 1/6-RU width; 2.78 x 1.65 x 5.5 in. (6.95 x 4.13 x 13.75
cm)

WEIGHT
9 oz. (0.26 kg)

OPTIONS
Rack tray (holds up to six units)

EXPOSURE TO EXTREMELY HIGH NOISE LEVELS MAY CAUSE A PERMANENT
HEARING LOSS.  INDIVIDUALS VARY CONSIDERABLY IN SUSCEPTIBILITY TO
NOISE INDUCED HEARING LOSS, BUT NEARLY EVERYONE WILL LOSE SOME
HEARING IF EXPOSED TO SUFFICIENTLY INTENSE NOISE FOR A SUFFICIENT
TIME. THE U.S. GOVERNMENT'S OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION (OSHA) HAS SPECIFIED THE FOLLOWING PERMISSIBLE
NOISE LEVEL EXPOSURES:

DURATION/DAY IN HOURS       SOUND LEVEL IN dBA, SLOW RESPONSE

8

90

6

92

4

95

3

97

2

100

1-1/2

102

1

105

1/2

110

1/4 or less

115

ACCORDING TO OSHA, ANY EXPOSURE IN EXCESS OF THE ABOVE
PERMISSIBLE LIMITS COULD RESULT IN HEARING LOSS. EAR PLUGS OR
PROTECTORS IN THE EAR CANALS OR OVER THE EARS MUST BE WORN
WHEN OPERATING THIS DEVICE IN ORDER TO PREVENT A PERMANENT
HEARING LOSS.  IF EXPOSURE IS IN EXCESS OF THE LIMITS AS SET FORTH
ABOVE, TO ENSURE AGAINST POTENTIALLY DANGEROUS EXPOSURE TO
HIGH SOUND PRESSURE LEVELS, IT IS RECOMMENDED THAT ALL PERSONS
EXPOSED TO EQUIPMENT CAPABLE OF PRODUCING HIGH SOUND
PRESSURE LEVELS SUCH AS THIS DEVICE BE PROTECTED BY HEARING
PROTECTORS WHILE THIS UNIT IS IN OPERATION.

1. Read all safety and operating instructions before using this product.
2. All safety and operating instructions should be retained for future reference.
3. Obey all cautions in the operating instructions and on the unit.
4. All operating instructions should be followed.
5. This product should not be used near water, i.e a bathtub, sink, swimming pool,
wet basement, etc.
6. This product should be located so that its position does not interfere with its
proper ventilation. It should not be placed flat against a wall or placed in a built-in
enclosure that will impede the flow of cooling air.
7. This product should not be placed near a source of heat such as a stove or
radiator.
8. Connect only to a power supply of the type marked on the unit adjacent to the
power.
9. Never break off the ground pin on the power supply cord.
10. Power supply cords should always be handled carefully. Never walk or place
equipment on power supply cords.   Periodically check cords for cuts or signs of
stress, especially at the plug and the point where the cord exits the unit.
11. The power supply cord should be unplugged when the unit is to be unused for
long periods of time.
12.  Care should be taken so that objects do not fall and liquids are not spilled into
the unit through the ventilation holes or any other openings.
13. This unit should be checked by a qualified service technician if:

 A. The power supply cord or plug has been damaged.
 B. Anything has fallen or been spilled into the unit.
 C. The unit does not operate correctly.
 D. The unit has been dropped or the enclosure damaged.

14. The user should not attempt to service this equipment. All service work should
be done by a qualified service technician.

CAUTIONS:

11

*Tests performed using an Audio Precision System One model 322 or equal.

(SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE)

Содержание FBX SOLO SL-610

Страница 1: ...y even during the program Another is the FBX micro filters are precisely placed while EQ filters are fixed The difference FBX filters do not have to be as deep so there is more system gain The most important advantage is that FBX micro filters are ten times narrower than 31 band EQ filters FBX micro filters return up to 90 percent of the power removed by EQ filters Over the years engineers stopped...

Страница 2: ...oubling the cost of your microphones speakers and power amp probably would not improve your system s frequency response as much as replacing your EQ with an FBX for chasing feedback 100 Hz 15 00 13 13 11 25 9 375 7 500 5 625 3 750 1 875 0 0 dBV 1K 10K Look for this symbol for specific information on the SL 610 for mixer insert points Look for this symbol for specific information on the SM 610 for ...

Страница 3: ...dback occurs during the program For many applications the optimal setting is the one which gives maximum gain i e four FIXED and two DYNAMIC filters default setting However in some applications such as use of wireless microphones mobility is more important than maximum gain In this case you may wish to set three fixed and three dynamic filters The filters can be reconfigured easily from the factor...

Страница 4: ...nect the SM 610 s line level output to an input on your mixer or amp See page 10 of this manual for information on use with a guitar amplifier The SM 610 input accepts both standard 1 4 phone and XLR input connectors 4 SL 610 Configuration2 SL 610 Configuration4 SL 610 Configuration3 SM 610 Setup ...

Страница 5: ...inimum 9 Slowly raise the input channel level fader for the channel being set until feedback occurs The SL 610 should quickly remove the feedback The first FILTER LED will then blink to indicate a filter has been set 10 Keep raising the level slowly until all FIXED FILTERS and one dynamic filter is set Any uninitialized dynamic filters will be set later if feedback occurs during the program 11 Now...

Страница 6: ... its red CLIP LED Then adjust the SM 610 MIC GAIN control one click counter clockwise to insure a margin of safety before clipping If your mixer has an input gain control adjust it to match the clip level of the SOLO 8 Adjust the mixer s master output to a nominal level usually 0dB 9 Slowly raise the channel level fader for the channel being set until feedback occurs The SM 610 should quickly remo...

Страница 7: ...uildings Gating microphones greatly reduces the number of possible feedback points in the room and allows for more system gain The level that turns the noise gate on and off is called the threshold If the level coming into the gate is greater than the threshold the noise gate opens and the mic is turned on If it is less than the threshold the noise gate closes and the mic is turned off You can adj...

Страница 8: ...The SM 610 will not pass signal if the power is off in either active or bypass mode RESETTINGTHEFILTERS TheusermustresettheFBXifthemicrophonesorspeakersaremovedsignificantly Toresettheunit pressRESETuntiltheLEDs stop flashing POWERDOWN Place the unit in BYPASS MODE before removing power from the unit LOCK FIXED FILTERS When the LOCK FIXED button is pressed its LED will light to indicate that the F...

Страница 9: ...pths of the filters in nonvolatile internal memory when the unit is turned off or during a power failure The unit will return all filters to their previous frequencies and depths when it is turned back on BYPASSMODE The SL 610 has a true power off bypass The signal is unaffected in bypass mode even if the unit is turned off If the unit is in active mode no signal will pass if the power is off Plac...

Страница 10: ...to filter as the SOLO finds new feedback points This gives the user a visual confirmation that the unit is functioning properly Q Why would the FBX cause a noticeable hum A It may hum if the system is improperly grounded Check for bad grounds Q Why does my system sound thin and muffled A Place the SOLO in BYPASS MODE If the system still sounds thin your problem is probably with improper use of a g...

Страница 11: ... OSHA ANY EXPOSURE IN EXCESS OF THE ABOVE PERMISSIBLE LIMITS COULD RESULT IN HEARING LOSS EAR PLUGS OR PROTECTORS IN THE EAR CANALS OR OVER THE EARS MUST BE WORN WHEN OPERATING THIS DEVICE IN ORDER TO PREVENT A PERMANENT HEARING LOSS IF EXPOSURE IS IN EXCESS OF THE LIMITS AS SET FORTH ABOVE TO ENSURE AGAINST POTENTIALLY DANGEROUS EXPOSURE TO HIGH SOUND PRESSURE LEVELS IT IS RECOMMENDED THAT ALL PE...

Страница 12: ...urchaser Sabine s liability to the purchaser for damages from any cause whatsoever and regardless of the form of action including negligence is limited to the actual damages up to the greater of 500 00 or an amount equal to the purchase price of the product that caused the damage or that is the subject of or is directly related to the cause of action Such purchase price will be that in effect for ...

Отзывы: