background image

7

LIMITING THE TOTAL NUMBER OF ACTIVE FILTERS
You may choose to limit the total number of active filters for each application by using the
"LOCK FIXED" button.  For example, if you wish to use only three fixed and one dynamic
filter, set the FBX so there are five fixed and one dynamic filter. Then during the setup
procedure, simply press the "LOCK FIXED" button after setting the first three fixed filters.
The remaining two fixed filters will be locked in their zero position.

SELECTING FILTER WIDTH
If the SOLO is to be used for a music application, 1/10-octave filters are most effective.
However, in spoken word applications, such as lectures or teleconferencing, the wider 1/5-
octave filters are recommended. Select the filter width using the switch on the SOLO back
panel. The change takes effect only on power-up. Selecting a new width has no effect unless
you power down and then power up again.

ENGAGING THE NOISE GATE
One outstanding feature of your FBX-SOLO is a user-selectable noise gate. It acts as an
automatic switch that opens a microphone only when someone is speaking directly into the
mic. A noise gate is especially useful in systems that have a number of open microphones,
such as courtrooms, conference rooms, or parliament buildings. Gating microphones greatly
reduces the number of possible feedback points in the room and allows for more system
gain.

The level that turns the noise gate on and off is called the threshold. If the level coming into
the gate is greater than the threshold, the noise gate opens, and the mic is
turned on. If it is less than the threshold, the noise gate closes, and the mic is
turned off.

You can adjust your SOLO to four different threshold levels (see diagram at
right), or turn it off. To select the threshold, power down the SOLO. Hold in
the LOCK FIXED button, and power up the SOLO. The clip level LEDs will
light in sequence. Select the threshold level by pressing the LOCK FIXED
button again when the clip LED lights at the corresponding threshold level.
The noise gate is now enabled, indicated by a flashing level LED on power-
up. Pressing the LOCK FIXED button with no clip LEDs lighted turns off
the noise gate. If no lights flash on power-up, the noise gate is not
engaged. 
When the SOLO's noise gate is enabled, it will not become
engaged until after you've set all fixed filters and one dynamic filter (if the
SOLO is configured for any).

USING SABINE'S OPTIONAL SOLO ACCESSORIES
1-U rack tray (model #SL6RACK):
An optional 1-U rack tray holds up to six SOLOs. Mount the SL-610s, SM-610s, or a combi-
nation of both side by side on the tray. Use only Sabine supplied screws; use of any other
screws may damage the SOLO and void the warranty.

Содержание FBX SOLO SL-610

Страница 1: ...y even during the program Another is the FBX micro filters are precisely placed while EQ filters are fixed The difference FBX filters do not have to be as deep so there is more system gain The most important advantage is that FBX micro filters are ten times narrower than 31 band EQ filters FBX micro filters return up to 90 percent of the power removed by EQ filters Over the years engineers stopped...

Страница 2: ...oubling the cost of your microphones speakers and power amp probably would not improve your system s frequency response as much as replacing your EQ with an FBX for chasing feedback 100 Hz 15 00 13 13 11 25 9 375 7 500 5 625 3 750 1 875 0 0 dBV 1K 10K Look for this symbol for specific information on the SL 610 for mixer insert points Look for this symbol for specific information on the SM 610 for ...

Страница 3: ...dback occurs during the program For many applications the optimal setting is the one which gives maximum gain i e four FIXED and two DYNAMIC filters default setting However in some applications such as use of wireless microphones mobility is more important than maximum gain In this case you may wish to set three fixed and three dynamic filters The filters can be reconfigured easily from the factor...

Страница 4: ...nect the SM 610 s line level output to an input on your mixer or amp See page 10 of this manual for information on use with a guitar amplifier The SM 610 input accepts both standard 1 4 phone and XLR input connectors 4 SL 610 Configuration2 SL 610 Configuration4 SL 610 Configuration3 SM 610 Setup ...

Страница 5: ...inimum 9 Slowly raise the input channel level fader for the channel being set until feedback occurs The SL 610 should quickly remove the feedback The first FILTER LED will then blink to indicate a filter has been set 10 Keep raising the level slowly until all FIXED FILTERS and one dynamic filter is set Any uninitialized dynamic filters will be set later if feedback occurs during the program 11 Now...

Страница 6: ... its red CLIP LED Then adjust the SM 610 MIC GAIN control one click counter clockwise to insure a margin of safety before clipping If your mixer has an input gain control adjust it to match the clip level of the SOLO 8 Adjust the mixer s master output to a nominal level usually 0dB 9 Slowly raise the channel level fader for the channel being set until feedback occurs The SM 610 should quickly remo...

Страница 7: ...uildings Gating microphones greatly reduces the number of possible feedback points in the room and allows for more system gain The level that turns the noise gate on and off is called the threshold If the level coming into the gate is greater than the threshold the noise gate opens and the mic is turned on If it is less than the threshold the noise gate closes and the mic is turned off You can adj...

Страница 8: ...The SM 610 will not pass signal if the power is off in either active or bypass mode RESETTINGTHEFILTERS TheusermustresettheFBXifthemicrophonesorspeakersaremovedsignificantly Toresettheunit pressRESETuntiltheLEDs stop flashing POWERDOWN Place the unit in BYPASS MODE before removing power from the unit LOCK FIXED FILTERS When the LOCK FIXED button is pressed its LED will light to indicate that the F...

Страница 9: ...pths of the filters in nonvolatile internal memory when the unit is turned off or during a power failure The unit will return all filters to their previous frequencies and depths when it is turned back on BYPASSMODE The SL 610 has a true power off bypass The signal is unaffected in bypass mode even if the unit is turned off If the unit is in active mode no signal will pass if the power is off Plac...

Страница 10: ...to filter as the SOLO finds new feedback points This gives the user a visual confirmation that the unit is functioning properly Q Why would the FBX cause a noticeable hum A It may hum if the system is improperly grounded Check for bad grounds Q Why does my system sound thin and muffled A Place the SOLO in BYPASS MODE If the system still sounds thin your problem is probably with improper use of a g...

Страница 11: ... OSHA ANY EXPOSURE IN EXCESS OF THE ABOVE PERMISSIBLE LIMITS COULD RESULT IN HEARING LOSS EAR PLUGS OR PROTECTORS IN THE EAR CANALS OR OVER THE EARS MUST BE WORN WHEN OPERATING THIS DEVICE IN ORDER TO PREVENT A PERMANENT HEARING LOSS IF EXPOSURE IS IN EXCESS OF THE LIMITS AS SET FORTH ABOVE TO ENSURE AGAINST POTENTIALLY DANGEROUS EXPOSURE TO HIGH SOUND PRESSURE LEVELS IT IS RECOMMENDED THAT ALL PE...

Страница 12: ...urchaser Sabine s liability to the purchaser for damages from any cause whatsoever and regardless of the form of action including negligence is limited to the actual damages up to the greater of 500 00 or an amount equal to the purchase price of the product that caused the damage or that is the subject of or is directly related to the cause of action Such purchase price will be that in effect for ...

Отзывы: