R5
SUPREME Secure W-AIS System
SOFTWARE UPGRADE
7000 118-524, C1
Page 13
2.3
Upgrade Software in R5 SUPREME Transponder via Junction Box.
The R5 SUPREME Transponder can also be upgraded through the USB host interface
located in the R5 AIS Junction Box (revision C and later). To upgrade the software in the
R5 SUPREME Transponder, perform the following steps:
Insert the prepared USB memory stick in the USB host interface in the R5 AIS
Junction Box.
Make sure that the R5 SUPREME Transponder’s 26-pin
I/O
port is connected to the
R5 Junction Box.
Hold down the ‘SW-LOAD’-button in the R5 AIS Junction Box. The R5 SUPREME
Transponder will reboot and start the software upgrade. The ‘SW-LOAD’-button must
be held down until the transponder
STATUS LED
is lit green and the transponder
Rx
LED
is lit yellow.
2.4
Upgrade Software in R5 SUPREME CDU
The R5 SUPREME CDU is upgraded through the USB host interface located behind the
front hatch. To upgrade the software in the R5 SUPREME CDU, perform the following
steps:
Unzip the R5 SUPREME CDU upgrade package in the root folder of an USB memory
stick (must be FAT32 formatted). There should now be a folder called cduswload in
the USB root folder.
Insert the USB memory stick in the USB host interface located behind the front hatch.
Hold down the ‘Down Arrow’-button on the front of the R5 SUPREME CDU
and reboot the system. The ‘Down Arrow’-button must be held down until the
STATUS LED
is lit green and the
RAIM LED
is lit yellow.
The software upgrade is complete when the
STATUS LED
is lit green. The R5 SUPREME
CDU will automatically reboot after 3 seconds. Check that correct SW has been loaded in
the SW/HW Info view which can be accessed through
Main Menu
Status
SW/HW
Info
.
If the upgrade process fails, The
STATUS LED
will be lit red and one of the
RAIM LED
or
MODE LED
starts blinking. Should this happen, hold down the ‘Down Arrow’-button and
reboot the R5 SUPREME CDU to try again.
The software upgrade can also be initiated from the
Update CDU Software
view in the R5
SUPREME CDU which can be accessed from
Main Menu
Maintenance
System
Update
Update CDU SW
.
Figure 4
– Update CDU SW