Conditioner Installation Picture

Indoor Unit

Installing the Indoor Unit

1. Mounting the installation steel plate

Select the structure part (e.g. a Colum etc) on the wall and 
mount the installation plate horizontally.

To prevent slight vibration from the installation plate the holes 
marked 

on the above diagram must be anchored and the holes 

marked may be anchored by all means.

If the bolts embedded in the concrete wall are used, mount the installation plate using 11x20. 11x26 
ellipsoidal holes which distance is about 450mm. If the embedded bolts are too long use short ones 
in the market.

2. Making a hole in the wall

Identify the position of the hole. The height should 
be lower than the bottom edge of the indoor unit.
Drill 65mm diameter hole and then insert the wall 
socket.

When you think that trouble has occurred

It s n ot a  m

  alfunctionin  t he f ollowings ituations:  

1. The air conditioner will not operate for approximately 3 minutes when restarted. This automatically 

protects the air conditioners microprocessor.  

2. Air does not flow out quickly in the heating operation Wait while the air conditioner is preparing to blow 

out warm air. 

3. The operation keeps stopping for approximately 2-12 minutes in the heating operation while the operation 

Indicator lamp lit. The outdoor unit defrosts (defrosting operation) when the external temperature is too

low and humidity is too high.   

4. Cracking sound is heard from the indoor unit. This sound is generated by the expansion or contraction of

 the front panel etc. This is due to changes in temperature. 

5. Room air smells funny. The air conditioner sucks internal odour and blows it out with air.
6. Fan stops during DRY operation. If water condensing to the heat exchanger evaporates again the humidity 

increases. To prevent this, the fan operation of the indoor unit stops until the room temperature has 
dropped sufficiently.  

7. Water flowing sound is heard during operation. This is the sound of refrigerant flowing inside the air 

conditioner. 

8. Mist appears during COOL operation. The indoor warm air is cooled when the room temperature and the 

humidity is high. When the room temperature and humidity reduce the mist will disappear.

9. A mechanical sound is heard from the indoor unit. This is the sound of the switch turning the fan or 

compressor ON/OFF.

10. Water leaks from the outdoor unit. During cooling operation. The pipe or pipe connector section are cool 

and cause water to condense. Water adhering to the heat exchanger during heating operation drips. 

11. Thunder may cause operation failure. Stop the operation and pull out the power plug or turn off the breaker. 

After a bout 3 minutesre-start the unit.

12. The remote control signal cannot be received. When direct sunlight or strong lamplight shines on the remote 

control receiving section of indoor unit. The remote control signal may not be received. Shelter from the 
direct s unlight or turn down the lamplight. 

13. Airflow direction is changed during operation. When the air conditioner is operated in the COOL or DRY 

mode with air blowing down for 1 hour. The direction is automatically set to level to prevent condensed 
water from dropping. While in heating operation, if the output air temperature is too low or when defrosting  
is done. The horizontal vane position is automatically set to horizontal. 

14. Frost adheres to the vertical vanes. If the unit operates in high humidity for a lengthy time, water may 

condense on the vertical vanes and drip.

PLEASE NOTE:If the above items are checked and the air conditioner does not recover, Stop using it and  
consult the service dealer or the manufacturer advising the product type and the failure details.

Wall thickness

(Indoor side)
(Seetion of wall hole)

Wall hole

ID

 65mm

OUTDOOR UNIT

Pipes to the
 indoor and 
outdoor units

SOLAR PANEL

Connect the Solar Panel 
to the Pipes A1  and A2 

Packing Tape 

A1

A2

B1

B2

14| 

Page

15  | 

Page

A1      A2     B1     B2

A1      A2     

B1     B2

Rope should aim
 at mark

Weight

Installation plate

Trapping screw 

4x25

Min 105mm(apart 
from the wall)

put the rope on the 
centred hole 

Min.height 24mm

Min 155mm(apart from the wall)

Содержание TKF-26GW/BP

Страница 1: ...P 9000BTU TKF R 35GW BP 12000BTU TKF R 50GW BP 18000BTU TKF R 70GW BP 24000BTU TKF R 100GW BP 36000BTU TKF R 120GW BP 41000BTU TKF R 140GW BP 48000BTU SOLAR AIR CONDITIONER OPERATION AND INSTALLATION...

Страница 2: ...ting Page 18 Draining Piping Work Page 18 Sealing of the Wall Hole Fixing of the Piping Page 19 Electric Wiring Connection Trial Operation Page 20 Electric Wiring Connection Page 20 Trial Operation Pa...

Страница 3: ......

Страница 4: ...ration 1 Press the ON OFF button to stop the air conditioner 1 Press the ON OFFbutton to start the air conditioner 2 To select AUTO mode press the Operation select button Each time the button is press...

Страница 5: ...he TIMER ON button and the will flash on the screen 3 When the icon flashes the start timer can be set Press the HOUR and Minute buttons to adjust the required time 4 Once the start time has been set...

Страница 6: ...considering yourhealth we recommend you use the unit as follows If the air conditioner cannot be operated ensure 1 The power plug is connected The switch is turned on and the fuse is not blown 2 The l...

Страница 7: ...humidity etc Cleaning of the Air Filter and Deodorising Filter Cleaning the air filter every 2 weeks 1 Open the front panel to the position as shown and remove the air filter The position of the fron...

Страница 8: ...his is the sound of refrigerant flowing inside the air conditioner 8 Mist appears during COOL operation The indoor warm air is cooled when the room temperature and the humidity is high When the room t...

Страница 9: ...UT 9 52 3 8 12 7 1 2 6 35 1 4 22000 24000 BUT 9 52 3 8 15 88 5 8 9 52 3 8 Pipe Diameter inch Tightening Torque kgf cm 1 4 220 280 3 8 350 420 1 2 530 590 5 8 750 800 3 Refrigerant and drainage piping...

Страница 10: ...rts to increase rapidly stop temporarily then turn through 60 90 angle If the pipe length is more than 3m charge the system with additional refrigerant Draining Piping Work In order to confirm that th...

Страница 11: ...ightly Trial operation Before trial operation be sure to check for looseness in wiring and mistaken polarity etc 1 Connect the power plug then turn on the mains switch Observe if the operation indicat...

Отзывы: