Solar Assisted Air
-
Conditioner Installation Picture
Indoor Unit
Installing the Indoor Unit
1. Mounting the installation steel plate
Select the structure part (e.g. a Colum etc) on the wall and
mount the installation plate horizontally.
To prevent slight vibration from the installation plate the holes
marked
on the above diagram must be anchored and the holes
marked may be anchored by all means.
If the bolts embedded in the concrete wall are used, mount the installation plate using 11x20. 11x26
ellipsoidal holes which distance is about 450mm. If the embedded bolts are too long use short ones
in the market.
2. Making a hole in the wall
Identify the position of the hole. The height should
be lower than the bottom edge of the indoor unit.
Drill 65mm diameter hole and then insert the wall
socket.
When you think that trouble has occurred
It s n ot a m
alfunctionin t he f ollowings ituations:
1. The air conditioner will not operate for approximately 3 minutes when restarted. This automatically
protects the air conditioners microprocessor.
2. Air does not flow out quickly in the heating operation Wait while the air conditioner is preparing to blow
out warm air.
3. The operation keeps stopping for approximately 2-12 minutes in the heating operation while the operation
Indicator lamp lit. The outdoor unit defrosts (defrosting operation) when the external temperature is too
low and humidity is too high.
4. Cracking sound is heard from the indoor unit. This sound is generated by the expansion or contraction of
the front panel etc. This is due to changes in temperature.
5. Room air smells funny. The air conditioner sucks internal odour and blows it out with air.
6. Fan stops during DRY operation. If water condensing to the heat exchanger evaporates again the humidity
increases. To prevent this, the fan operation of the indoor unit stops until the room temperature has
dropped sufficiently.
7. Water flowing sound is heard during operation. This is the sound of refrigerant flowing inside the air
conditioner.
8. Mist appears during COOL operation. The indoor warm air is cooled when the room temperature and the
humidity is high. When the room temperature and humidity reduce the mist will disappear.
9. A mechanical sound is heard from the indoor unit. This is the sound of the switch turning the fan or
compressor ON/OFF.
10. Water leaks from the outdoor unit. During cooling operation. The pipe or pipe connector section are cool
and cause water to condense. Water adhering to the heat exchanger during heating operation drips.
11. Thunder may cause operation failure. Stop the operation and pull out the power plug or turn off the breaker.
After a bout 3 minutesre-start the unit.
12. The remote control signal cannot be received. When direct sunlight or strong lamplight shines on the remote
control receiving section of indoor unit. The remote control signal may not be received. Shelter from the
direct s unlight or turn down the lamplight.
13. Airflow direction is changed during operation. When the air conditioner is operated in the COOL or DRY
mode with air blowing down for 1 hour. The direction is automatically set to level to prevent condensed
water from dropping. While in heating operation, if the output air temperature is too low or when defrosting
is done. The horizontal vane position is automatically set to horizontal.
14. Frost adheres to the vertical vanes. If the unit operates in high humidity for a lengthy time, water may
condense on the vertical vanes and drip.
PLEASE NOTE:If the above items are checked and the air conditioner does not recover, Stop using it and
consult the service dealer or the manufacturer advising the product type and the failure details.
Wall thickness
(Indoor side)
(Seetion of wall hole)
Wall hole
ID
65mm
OUTDOOR UNIT
Pipes to the
indoor and
outdoor units
SOLAR PANEL
Connect the Solar Panel
to the Pipes A1 and A2
Packing Tape
A1
A2
B1
B2
14|
Page
15 |
Page
A1 A2 B1 B2
A1 A2
B1 B2
Rope should aim
at mark
Weight
Installation plate
Trapping screw
4x25
Min 105mm(apart
from the wall)
put the rope on the
centred hole
Min.height 24mm
Min 155mm(apart from the wall)
Содержание TKF-26GW/BP
Страница 3: ......