background image

In DRY Operation

1. The DRY mode should be used to reduce the humidity of the room
2. In DRY operation, the fan speed cannot be changed. There will be a 3 minute delay until fans start. 
3. The fans in the outdoor and indoor unites are controlled by the microprocessor and the fans will 

operate occasionally in DRY operation.

4. The room temperature is slightly lowered in the DRY mode.This mode cannot be used when the 

current room temperature is 13 Or lower.   

5. In order to reduce stress on the compressor, the unit cannot be operated for 3 minutes after either a 

power failure or the DRY operation is stopped.

Air Flow Velocity and Direction Adjustment

1. Press the FAN button to adjust the velocity of the air flow. Each time the button is pressed the fan speed is 

changed as follows.  AUTO 

          

LOW          MEDIUM          HIGH

2. To adjust the direction of the air flow press the HORIZONTAL VANE CONTROL button       . Each time the  

button is pressed the horizontal vanes will change position from 

.

3. When COOL or DRY mode has been selected the most effective Position of the horizontal vanes is wither 

or

 

and when HEAT mode is selec ted the most effective positions are  and

.

 

4. Once the desired room temperature has been reached the swing mode 

 

should be selected.

PLEASE NOTE:To change the horizontal air flow direction adjust the vertical vanes manually before operation 
starts as the horizontal vanes can move automatically and your fingers may get caught.  

To Set Timer on Function

 

1. The unit must be off when you begin setting the TIMER on function.

2. Press the TIMER ON button          and the  

 

will flash on the screen. 

3. When the icon flashes the start timer can be set. Press the HOUR and Minute buttons to adjust the 

required time.   

4. Once the start time has been set, press the Set Temp button to send the Timer On setting to the unit.

5. To cancel the operation press the Timer ON button         again. 

To Set the Timer Off Function 

1. The unit must be on when you begin setting the TIMER OFF function.

2. Press the TIMER OFF button        and the            will flash on the screen. 
3. When the icon flashes the finish time can be set by pressing the Hour and Minute Buttons to adjust 

the time required. 

4. Once the finish time has been set press the Set Temp button to send the Timer Off setting to the unit.
5. To Cancel the operation press the Set Temp Button to send the TIMER OFF Setting to the unit.   

6. To cancel the operation press the TIMER OFF Button        again. 

Set the Comfortable Sleep Mode Function 

1. Ensure the machine is on 

2. Press the Sleep Button           to start the sleep mode function.

Sleep Function

1. The indoor fan motor changes to a low speed 
2. In cool operation mode each hour the temperature will raise by 1

(max 2 )

3. In heat operation mode each hour the temperature will raise by 1 (max 2 )
4. In dry operation the temperature will not change.

To Cancel the Sleep Function

You can cancel the sleep function mode by selecting one of the below methods:

1. Press the Sleep Button

again

2. Press the ON/OFF Button

 

3. Press the Mode Button 
4. Press the Fan Button to change the fan speed.

 e Button F 

unction

1. Press the  e Button  once the unit goes into AUTO function mode which will adjust the fan speed 

swing function and mode settings automatically. 

2.

To cancel  this function press the Mode Button.

8 | 

Page

9  | 

Page

Содержание TKF-26GW/BP

Страница 1: ...P 9000BTU TKF R 35GW BP 12000BTU TKF R 50GW BP 18000BTU TKF R 70GW BP 24000BTU TKF R 100GW BP 36000BTU TKF R 120GW BP 41000BTU TKF R 140GW BP 48000BTU SOLAR AIR CONDITIONER OPERATION AND INSTALLATION...

Страница 2: ...ting Page 18 Draining Piping Work Page 18 Sealing of the Wall Hole Fixing of the Piping Page 19 Electric Wiring Connection Trial Operation Page 20 Electric Wiring Connection Page 20 Trial Operation Pa...

Страница 3: ......

Страница 4: ...ration 1 Press the ON OFF button to stop the air conditioner 1 Press the ON OFFbutton to start the air conditioner 2 To select AUTO mode press the Operation select button Each time the button is press...

Страница 5: ...he TIMER ON button and the will flash on the screen 3 When the icon flashes the start timer can be set Press the HOUR and Minute buttons to adjust the required time 4 Once the start time has been set...

Страница 6: ...considering yourhealth we recommend you use the unit as follows If the air conditioner cannot be operated ensure 1 The power plug is connected The switch is turned on and the fuse is not blown 2 The l...

Страница 7: ...humidity etc Cleaning of the Air Filter and Deodorising Filter Cleaning the air filter every 2 weeks 1 Open the front panel to the position as shown and remove the air filter The position of the fron...

Страница 8: ...his is the sound of refrigerant flowing inside the air conditioner 8 Mist appears during COOL operation The indoor warm air is cooled when the room temperature and the humidity is high When the room t...

Страница 9: ...UT 9 52 3 8 12 7 1 2 6 35 1 4 22000 24000 BUT 9 52 3 8 15 88 5 8 9 52 3 8 Pipe Diameter inch Tightening Torque kgf cm 1 4 220 280 3 8 350 420 1 2 530 590 5 8 750 800 3 Refrigerant and drainage piping...

Страница 10: ...rts to increase rapidly stop temporarily then turn through 60 90 angle If the pipe length is more than 3m charge the system with additional refrigerant Draining Piping Work In order to confirm that th...

Страница 11: ...ightly Trial operation Before trial operation be sure to check for looseness in wiring and mistaken polarity etc 1 Connect the power plug then turn on the mains switch Observe if the operation indicat...