background image

 

3

MANUFACTURER’S PLACEMENT INSTRUCTIONS 

 
 
The Rogue

TM

 Grand Rapids

TM

 owner must confirm that the Installer has followed 

the Manufacturer’s Placement Instructions. 
 
 
1.  The critical dimensions for placement of the slide are as shown in FIGURES I and J. 
 

 

A.  The slide exit runway surface shall not exceed twenty inches (20”) above the 

water surface and not less than eight inches (8”) above the deck/coping surface 
(see Figure I). 

B.  The slide shall be positioned so that all water flowing off the runway exit drops 

into the pool. 

C.  The minimum depth of water below the exit lip of the slide shall be three feet (3’) 

and increases to four feet six inches (4’-6”) at Pt.A, which is a distance of four 
feet six inches (4’-6”) from the exit lip of the slide.  (see Figure I). 

D.  A minimum depth of four feet six inches (4’-6”) shall be maintained at a distance 

of nine feet (9’) along the extended centerline of the slide from Pt.A. (see 
FIGURE I). 

2.  A minimum clearance area in front of the slide shall be 
maintained away from the coping, another slide, a diving 
board or a rope and float line.  (see FIGURE L) 
 

A.  The minimum clearance distance on either side of the 

extended centerline of the slide runway shall not be 
less than three feet six inches (3’-6”) at a point no 
less than two feet six inches (2’-6”) from the exit of 
the slide and extending a distance of thirteen feet six 
inches (13’-6”) in front of the slide.  (see FIGURE J) 

 

B.  The minimum clearance area in front of a diving 

board is a minimum distance of three feet six inches 
(3’-6”) on either side of the board’s centerline.  Pt.C  
extends a minimum distance of “C” from the tip end of 
the board.  The width distance “W” on either side of 
Pt.C is given in CHART 1 and shown in FIGURE K. 

 

 

FIGURE I 

FIGURE J 

Содержание ROGUE GRAND RAPIDS

Страница 1: ...03 266 2231 503 266 4334 www srsmith com 06 677 S R SMITH LLC 2005 JUN11 C A U T I O N S R SMITH ROGUETM GRAND RAPIDSTM ARE MANUFACTURED FOR INSTALLATION AND USE ON RESIDENTIAL INGROUND POOLS ONLY ROG...

Страница 2: ...ground pools houseboats boat docks floating docks or platforms APPLICABLE STANDARDS AND CODES 1 All S R Smith RogueTM Grand RapidsTM are manufactured in accordance with Consumer Products Safety Commis...

Страница 3: ...imum depth of four feet six inches 4 6 shall be maintained at a distance of nine feet 9 along the extended centerline of the slide from Pt A see FIGURE I 2 A minimum clearance area in front of the sli...

Страница 4: ...diving board may intersect each other provided that they are not used simultaneously CHART 1 BOARD MINIMUM CLEARANCE AREA POOL TYPE C DIMENSION W DIMENSION I 14 6 5 0 II 14 6 6 0 III 16 6 6 0 IV 18 6...

Страница 5: ...exit end of slide Measure the height of the slide runway exit above the water 20 max Measure the distance between the slide centerline and the edge of other pool equipment 7 Observe the position of t...

Страница 6: ...chances Have the slide inspected and if necessary repaired by a competent professional who is familiar with acrylic water slides before using the Rogue Grand Rapids water slide again See INSTALLED SL...

Страница 7: ...water fittings are not leaking and clean spray nozzles to permit water to be sprayed on the slide runway 3 All anodized aluminum parts require little maintenance Hose and wipe to clean 4 While cleanin...

Страница 8: ...Tackle Spic and Span Powder Calgon Bath Topjob Clorox Bleach Glass Plus Tilex Always read the label instructions on any cleaner carefully before applying it to a Plexiglas DR acrylic surface AVOID HA...

Отзывы: