I N S TA L L AT I O N I N S T R U C T I O N S
WARNING
• TURN OFF INCOMING POWER BEFORE SERVICING EQUIPMENT.
• ALL INSTALLATION AND MAINTENANCE WORK MUST BE PERFORMED BY A
QUALIFIED ELECTRICIAN.
• GFCI BREAKER MUST BE USED TO CONNECT (p/n pLX-PL60/PL100) TO INPUT POWER.
• VERIFY ALL ELECTRICAL RATINGS BEFORE INSTALLATION IS COMPLETE.
• FOLLOW PROPER WIRING PRACTICES IN ACCORDANCE WITH ALL NATIONAL AND
LOCAL REGULATORY REQUIREMENTS.
E n c l o s u r e m o u n t i n g
1. Locate the poolLUX Plus (p/n pLX-PL60/PL100) in an appropriate area that meets the following
requirements:
a. Must be mounted on a flat vertical surface.
b. Must be a minimum of 4 inches above the ground level, pool deck, or higher than 8 inches
above the maximum pool water level, whichever provides greatest elevation.
c. Must be positioned a minimum of 4 feet (1.2 m) from the inside wall of the pool unless
separated from the pool by a solid fence, wall, or other permanent barrier.
For the unit to be adequately air cooled, allow a minimum gap of 9/32" (7.2mm) between the wall
and the back surface of the unit. The stand-off mounting tabs will make contact with the wall.
W
ALL
Minimum Gap of 9/32" or 7.2mm