5
I N S TA L L AT I O N I N S T R U C T I O N S
T Y P I C A L I N S TA L L AT I O N
1.
Per NEC Article 680.23 (5) lights are to be installed in no less than 18” (450mm) below
the normal water level unless the luminaire is listed and identified for use at lesser depths.
S.R.Smith lights are listed and identified for use at depths no less than 4” (100mm) below the
normal water level. Max depth is 36” below water surface. All depth measurements are from
the normal water level to the top of the Luminaire lens.
2.
Fit an S.R.Smith LNS-2G, LNS-2A, LNS-2V or similar 1 1/2” pool wall fitting into the pool wall
at the selected location. Watertight PVC conduit must be used from the wall fitting to the
above water/ground level conduit termination on the equipment or supply side of the 12V
AC line. Please refer to the illustration below.
3.
Fit the S.R.Smith
kēlo
LED Light into the 1 1/2” wall fitting as shown and carefully pull the
waterproof supply cable through. Carefully thread the S.R.Smith
kēlo
into the threads and
turn clockwise and gently tighten until secure. DO NOT Over-tighten the light as damage
may occur. Connect the red / black wire conductors of the S.R.Smith
kēlo
to an approved,
low voltage, class 2, Magnetic Type Power Source that complies with UL379 or an S.R.Smith
poolLUX™ brand power supply as required by NEC or relevant local codes and ordinances.
NOTE:
Even though the housing gasket (between Wall Fitting and Light) can be replaced by a
bead of silicon suitable for pool use, water will eventually fill the conduit so be sure the conduit is
watertight and terminates above ground.
FOR STANDARD 1 1/2” WALL FITTINGS IN A POOLS OR SPA
Luminaire is listed and
identified for use at 4” or
more below the normal
water level of the pool.
Optimal lighting coverage
may be found at 10-12”
below water level.
Maximum depth is 36”
*Approved 12VAC
Class 2 Power
Source
(see line #3 above)
1.5” watertight, underground
PVC conduit back to 12VAC
transformer.
All fittings should be glued and
watertight.
*Minimum of 3.5” of straight,
1.5” PVC conduit behind the
wall fitting required prior to
conduit reducer or bend.
back gasket
pool deck
4”Min
18”
NEC Article
680.23(5)
Содержание kelo LED light