INTRODUCTION

 

DANGER 

– FAILURE TO FOLLOW THESE WARNINGS, INSTRUCTIONS, AND THE 

OWNER’S MANUAL MAY RESULT IN SERIOUS INJURY OR DEATH. 

THE HELIX2 SLIDE IS DESIGNED AND MANUFACTURED FOR INSTALLATION AND USE ON 
INGROUND SWIMMING POOLS ONLY. DO NOT INSTALL THIS SLIDE ON ABOVE GROUND 
POOLS, HOUSEBOATS, BOAT DOCKS, FLOATING DOCKS OR PLATFORMS, OR OTHER BODIES 
OF WATER SUCH AS LAKES, PONDS, RIVERS, ETC. PROPER ASSEMBLY, INSTALLATION, USE, 
AND SUPERVISION ARE ESSENTIAL FOR PROPER OPERATION AND TO REDUCE THE RISK OF 
SERIOUS INJURY OR DEATH. 

ALL NATIONAL AND LOCAL BUILDING CODES MUST BE FOLLOWED. THIS INCLUDES ANY 
APPLIABLE REQUIREMENTS FOR SIZE OF CONCRETE FOOTING, OVERALL HEIGHT OF SLIDE, 
AND BODING OR ELECTRICAL CODES. 

CHECK INSIDE ALL BOXES AND PACKAGING MATERIALS FOR PARTS. BEFORE BEGINNING 
ASSEMBLY, READ ALL INSTRUCTIONS AND IDENTIFY PARTS USING THE FIGURES AND PARTS 
LISTED IN THIS DOCUMENT. IT IS CRITICAL THAT ALL PARTS BE CAREFULLY INSPECTED BY 
THE INSTALLER PRIOR TO INSTALLATION TO ENSURE THAT NO DAMAGE OCCURRED IN 
TRANSIT AND THAT A DAMAGED PART IS NOT USED. PROPER INSTALLATION CANNOT BE 
OVERSTRESSED, IMPROPER INSTALLATION VOIDS S.R. SMITH’S WARRANTY AND MAY 
AFFECT THE SAFETY OF THE USER. 

INSTALLER MUST GIVE TO SLIDE OWNER: HELIX2 INSTALLATION AND 

OWNER’S MANUAL, THE 

WARRANTY CARD, AND ANSWER ALL QUESTIONS REGARDING SAFE AND PROPER USE AND 
SLIDE MAINTENANCE. 

FOR COMPLETE SLIDE SAFETY INFORMATION REFER TO THE OWNER’S MANUAL. 

 

 

 

 

 

 

 

 

 

 

 

Содержание heliX2

Страница 1: ...ERS P O Box 400 1017 S W Berg Parkway Canby Oregon 97013 USA Phone 503 266 2231 Fax 503 266 4334 www srsmith com S R SMITH HELIX2 SLIDES ARE MANUFACTURED FOR INSTALLATION AND USE ON RESIDENTIAL INGROU...

Страница 2: ...ation 7 HELIX2 Assembly 8 ON DECK MOUNTING INSTRUCTIONS 15 SLIDE PLUMBING INSTRUCTIONS 16 MANUFACTURER S PLACEMENT INSTRUCTIONS 17 APPENDIX A A APPENDIX B B Visit srsmith com for information on the co...

Страница 3: ...IREMENTS FOR SIZE OF CONCRETE FOOTING OVERALL HEIGHT OF SLIDE AND BODING OR ELECTRICAL CODES CHECK INSIDE ALL BOXES AND PACKAGING MATERIALS FOR PARTS BEFORE BEGINNING ASSEMBLY READ ALL INSTRUCTIONS AN...

Страница 4: ...l equipment should be at least 3 6 1 067 M 6 Observe the position of the exit of the slide as shown in FIGURE N FIGURE O and FIGURE Q on pages 17 and 18 MAINTENANCE INSTRUCTIONS 1 When hosing down the...

Страница 5: ...5 ASSEMBLED HELIX2 LAYOUT FIGURE A See Appendices A and B for additional slide layout details NOT A PROJECTED VIEW...

Страница 6: ...1 ea 14 05 782 1 5 PVC Pipe Strap 2 ea 15 05 767 1 Pipe Clamp 2 ea 16 05 770 1 Ball Valve Gray 1 ea 17 05 784 1 Coupling 1 ea 18 05 773 Garden Hose Adapter 1 ea 19 8 532 5 HIGH X 5 WIDE X 32 LONG RUBB...

Страница 7: ...hipping If gasket installation is required follow the instructions below The gasket on the face of the ladder is not installed in the factory but detailed instructions are provided in step 8 on page 1...

Страница 8: ...exit part 1 4 6 mm pilot holes must be drilled into the center of each of the recesses each location is marked with a dimple showing where to drill The pilot holes should be drilled through both the...

Страница 9: ...to prevent galling 6 Insert the button head cap screws into the back side of the ladder as shown in FIGURE F Tighten the screws until snug Go back and fully tighten the screws from Step 5 Note Be sure...

Страница 10: ...eference images below Do not make too tight of a bend radius with the gasket when transitioning the gasket up the vertical edges of the joint The transition radius should be as large as possible Makin...

Страница 11: ...rdware shown in FIGURE G Tighten until the lock washer is fully compressed Notes It may take more than one person to perform this step Verify that the gasket material is properly attached before assem...

Страница 12: ...ng 12 Finish assembling the two runway sections using the hardware shown in FIGURE J Note Be sure to apply anti seize to all fasteners to prevent galling a First the 2 Hex Head Tap Bolt Item 13 should...

Страница 13: ...C Flex Hose 23 15 Once the plumbing fit and function has been verified remove the plumbing components from the ladder in preparation for final gluing and assembly 16 Use PVC primer and glue to permane...

Страница 14: ...14 24 23 20 21 16 27 GLUE TO FITTING IN LADDER Step 18 25 22 27 PUSH INTO SMALL BALL VALVE Step 19 20 16 22 FIGURE K 14 11 DETAIL C 15 11...

Страница 15: ...holes 4 Using a power drill and a 1 2 13 mm concrete drill bit drill the holes to a depth of 4 0 102 M Use tape or a marking on the drill bit to ensure that the hole for the anchor is drilled to the...

Страница 16: ...the deck attach the stub up to the plumbing assembly installed in the ladder 4 The HELIX2 can handle up to 20 gallons per minute 75 L min Water flow to the main water supply is to be regulated using t...

Страница 17: ...ne of the slide from Pt A as shown in FIGURE N 2 A minimum clearance area in front of the slide shall be maintained at all times as follows A The minimum clearance distance on either side of the exten...

Страница 18: ...contained in ANSI APSP ICC 5 2011 STANDARD FOR RESIDENTIAL INGROUND SWIMMING POOLS and refer to FIGURE 3 and Table 1 for Minimum Water Envelope Dimensions AB BC and Width at Point C TABLE 1 Board Mini...

Страница 19: ...A APPENDIX A...

Страница 20: ...B APPENDIX B...