background image

 

1/2 METER FRONTIER II JUMP STAND 

For 6’ and 8’ Frontier II Jump Boards 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

TIGHTENING SCHEDULE 
SECURE BOARD TO STAND WITH 
MOUNTING HEX NUTS 
FIBERGLASS: 20-25 FT-LBS. 
 
SECURE STAND TO JIG WITH: 
ANCHOR HEX NUTS 
40-50 FT-LBS. 
 
 

S.R. SMITH CANNOT GUARANTEE 
CUSTOMER’S CONCRETE OR 
THICKNESS 

IMPORTANT NOTICE:  
IT IS NECESSARY TO USE AN 
ANTI-SEIZE COMPOUND ON 
ALL STAINLESS STEEL 
HARDWARE.  FAILURE TO USE 
ANTI-SEIZE COMPOUND MAY 
RESULT IN GALLING AND 
SEIZING OF THE HARDWARE.

FIG. 1 

 

FIG.2 

 
 
 
 

FRONTIER II MOUNTING 
BOLT KIT (69-209-032-SS) 

 FRONTIER 

II 

SPRING 

ANCHOR BOLT KIT (69-209-033-SS) 

1. STEP BOLT HEAD CAP – WHITE RUBBER (3 EA.) 
2. 1/2” X 3” LG. STEP BOLT – S/S (3 EA.) 
3. 1/2” X 1-1/2” ROUND NYLON WASHER (3 EA.) 
4. 1/2” X 1-3/8” FLAT WASHER S/S (3 EA.) 
5. 1/2” LOCK WASHER S/S (3 EA.) 
6. 1/2” HEX NUT S/S (3 EA.) 
7. 1/2” WHITE PLASTIC NUT CAP (3 EA.) 

 

8. 5/8” X 1-3/4” NYLON PROTECTIVE WASHER (3 EA.) 
9. 5/8” X 1-3/4” FLAT WASHER S/S (3 EA.) 
10.  5/8” LOCK WASHER S/S (3 EA.) 
11.  5/8” HEX NUT S/S (3 EA.) 
12.  5/8” WHITE RUBBER NUT CAP (3 EA.) 

 

Содержание FRONTIER II

Страница 1: ...LY The S R Smith Frontier II Jump Stands are designed to be easily transported and installed Follow all instructions carefully and inspect closely to assure proper and safe installation PROPER INSTALLATION CANNOT BE OVERSTATED IMPROPER INSTALLATION VOIDS S R SMITH S WARRANTY AND MAY AFFECT THE SAFETY OF THE USER ASSEMBLY AND INSTALLATION INSTRUCTIONS PLEASE READ CAREFULLY WESTERN SALES AND MANUFAC...

Страница 2: ...URE TO USE ANTI SEIZE COMPOUND MAY RESULT IN GALLING AND SEIZING OF THE HARDWARE FIG 1 FIG 2 FRONTIER II MOUNTING BOLT KIT 69 209 032 SS FRONTIER II SPRING ANCHOR BOLT KIT 69 209 033 SS 1 STEP BOLT HEAD CAP WHITE RUBBER 3 EA 2 1 2 X 3 LG STEP BOLT S S 3 EA 3 1 2 X 1 1 2 ROUND NYLON WASHER 3 EA 4 1 2 X 1 3 8 FLAT WASHER S S 3 EA 5 1 2 LOCK WASHER S S 3 EA 6 1 2 HEX NUT S S 3 EA 7 1 2 WHITE PLASTIC ...

Страница 3: ...with the INSTALLATION CHART above and Fig 1 with the RED capped bolt closest to the pool This will give the desired minimum overhang Board must be placed at deep end of pool on centerline CAUTION Before pouring concrete around jig check the bolt pattern of jig to Fig 2 It is possible that they have become misaligned through shipping and handling 3 Make sure bolts project out of concrete 1 1 2 with...

Страница 4: ...xcept where noted as maximum 4 One half 1 2 the width shown at each point shall be available on each side of the diving equipment centerline 5 Minimum water depth under tip of diving board Point A is important to maintain SEE TABLE 2 FOR DIMENSIONS F N K J B L C L SYM M N L C SYM D 6 R MAX H A L C SYM C L C SYM 2 3 R MAX G F CROSS SECTION AT POINT C WATER LEVEL WATER LEVEL CROSS SECTION AT POINT A...

Страница 5: ...shape of pools except that consideration shall be given to shape from the standpoint of circulation of the swimming pool water and safety to the user 5 3 Walls requirements 5 3 1 Walls in the shallow area and deep area of the pool shall not slope greater than 11 1 5 slope ratio to a transition point The transition point shall not be less than 2 feet and 9 inches 83 8 cm below the waterline See Fig...

Страница 6: ... minimum diving water envelope shall be plumb or outside of Type 1 water geometry See figure 3 ta ble 1 5 4 Maximum allowable wall slope 5 4 1 Maximum allowable wall slope shall not slope greater than 11º from plumb Figure 3 Minimum water envelope B ...

Страница 7: ...llow end except as specified in 6 3 5 6 3 The slope of the floor from the point of the first slope change toward the deep end shall not exceed 1 foot in 3 feet 30 cm 91 cm Table 1 Minimum water envelope Minimum depths at point Minimum widths at point Minimum lengths between points Pool type A B C D A B C D WA AB BC CD DE WE O Manufactured diving equipment is prohibited I 6 0 7 6 5 0 2 9 10 0 12 0 ...

Страница 8: ... surfaces 5 9 Figure 3 contains suggested drawings and diagrams for minimum water envelope for swimming pools designated type I V Individual pool types are shown in figure 3 and table 1 5 9 1 Location of point A Point A shall be defined as a point located on the minimum water envelopes 5 9 1 1 Point A Point A is a construc tion location nearest the deep end wall where the minimum water depth is sa...

Страница 9: ...or Residential Inground Swimming Pools contact Figure 6 Top view examples of accessory equipment and pool features prohibited in the water envelope National Spa and Pool Institute 2111 Eisenhower Avenue Alexandria VA 22314 Phone 703 838 0083 Fax 703 549 0493 www nspi org E ...