DO NOT ALLOW AIR VENTS TO BE BLOCKED! 

 

 

Your 6004 / 6004-AS illuminator needs air to breathe! Lack of ventilation can cause the 
unit to overheat. This will shorten the lamp life and could damage the unit. DAMAGE TO 
THE UNIT BECAUSE OF BLOCKED AIR VENTS IS NOT COVERED UNDER OUR 
WARRANTY! 

TROUBLE SHOOTING 

-THERE IS NO LIGHT 

You can hear the fan running:

 The lamp has probably failed. Replace with SR Smith part# Y20-6000. 

There is no fan running:

 The illuminator is not getting power. Check the toggle switch position by referring to the 

diagram on the front of this manual. Check the GFCI breaker and check the fuse on the illuminator. 

-THE UNIT SHUTS OFF AFTER A FEW MINUTES THEN COMES BACK ON 

Check to see if the air vents are blocked. Refer to the above drawing to make sure the vents are clear. 
Turn off power and remove the two screws securing the cover and check for obstruction in the cooling fan. 

-REMOTE CONTROL UNITS (WITH OPTIONAL RM6000 PACKAGE-with its own separate warranty coverage) 

YOU CAN TEMPORARILY OPERATE THE UNIT MANUALLY VIA THE TOGGLE SWITCHES IF A REMOTE 
CONTROL PROBLEM IS SUSPECTED. SEE DIAGRAM ON THE FRONT OF THIS MANUAL. 

There is a click at the unit when the button is pressed, but no light

: If you hear the fan running, the lamp has 

probably failed. Replace with SR Smith part #Y20-6000. If you cannot hear the fan running, the receiver module is 
probably defective. Have a qualified service company replace it. 

There is NO click at the unit when the button is pressed:

 Make sure that the transmitter is TURNED ON. The red 

light on the transmitter should glow when a button is depressed. If the transmitter is functioning properly, but the 
illuminator still does not come on, the receiver module may be defective. Have a qualified service company replace it. 
YOU CAN TEMPORARILY OPERATE THE UNIT MANUALLY VIA TOGGLE SWITCHES. SEE THE DIAGRAM ON THE 
FRONT OF THIS MANUAL. 

-LIGHTS ARE NOT BRIGHT ENOUGH 

The adequacy of pool lighting is subjective at best. What is acceptable to most, may not be for some. The pool builder is 
given guidelines by SR Smith, and the builder alone is responsible for the final design and installation. There are many 
factors that determine the ultimate brightness of our product; fiber lengths, pool finish color, installation techniques, etc. 
Remember that darker color on our color wheel, i.e. magenta, are not as bright as lighter colors like white 

 