17
Bill returned
The bill has been returned because you
pressed on the reject button.
Defective motor
The motor pulling the bill is defective.
Invalid escrow req.
Stack or reject command cannot be performed
as the bill is already in bill box.
Not available
This option is not available with this type of bill
acceptor.
ROM checksum error The checksum of the bill acceptor does not the
calculated checksum.
Sensor problem
One of the sensors has failed to provide its
response.
Stacker count
Amount of bill into the bill box
Stacker is full
Stacker full, cannot accept further bills.
Unit disabled
Bill acceptor does not have the permission to
accept bills.
Unit must be enabled Escrow button activated while accept line is
OFF.
Acceptor busy
Bill acceptor is performing a task and cannot
answer a request.
Acceptor jammed
Bill stuck in the bill path.
Acceptor was reset
Bill acceptor has been reset.
Disabled/rejected
The bill acceptor does not have the permission
to accept this type of bill.
$xx in escrow
The bill displayed is currently in escrow posi
tion waiting to be stacked or rejected.
Stacked
Value of the bill being stacked plus total
amount inserted so far.
Turn the ACCEPT LINE off. The bill acceptor should not accept bill.
Test many denominations. Test many bills of each denomination as
well.
When finished, press on STOP before unplugging the unit.
Once everything tested and cleaned, you can slip your bill acceptor into
a bag, write a short memo and put that changer on a shelf for future
use.