14
Defective sensors
A high level sensor is activated while the low is
not. Either a defective top sensor or a foreign
object stuck at the top of the tube. Usually, this
message will be visible after a payout of the
tube having the error.
Device is short
There is short circuit inside the unit under test.
Escrow return
The coin return lever was activated.
No credit
Coin accepted and directed to the tube or the
cashbox. However, that coin was not detected
in either place. Check for jammed path. Also
check for coin sensors in acceptor.
No tube payout
No coin value linked to this push button. Even
if the tube is present, it may have an identical
value as another. In MDB mode, two 25¢ tubes
will be seen as one tube. As an example, a
coin changer having 3 x 25¢ and 2 x 1$ tubes
will be seen as a two-tube changer (25¢ & 1$).
Pay out busy
Changer is telling the VMC it is currently dis-
pensing change.
Please wait
The CTX is waiting.
ROM Checksum
The checksum of the coin changer does not
error match with its internal memory because of
corrupted data. Unit must be sent to a service
centre.
Routing error
A validated coin did not follow the intended
route. It went to the cashbox but was meant to
go the tubes or vice-versa. Check the gate in
the acceptor.
Tube jam
The coin changer has detected a coin jam into
one of its tubes.
Slug
Unknown coin inserted. If the coin is genuine, it
means the coin acceptor has totally lost its rec-
ognition capability (memory erased) and must
be sent to a service center for re-programming.
In a Level 2 coin changer, the state of the tubes will be indicated as fol-
low:
HI=
Both sensors, low and high, are covered with coins.
LO=
Low sensor is covered with coins.
NO=
No sensors are covered with coins, most likely, the
tube is empty.
DEF= Defective sensor in tube.