3
English
|
EN
FR
DE
ES
IT
NL
PT
DA
SV
FI
NO
RU
PL
CS
HU
RO
LV
LT
ET
HR
SL
SK
BG
UK
TR
■
Remove the battery pack before filling the container.
Wipe off any spills before installing the battery pack.
■
Stand the product on a level surface, and do not fill the
container above the maximum mark.
■
When filling from the tap, do not immerse the end of
the hose in the chemical solution. Sudden low pressure
in the system may cause the chemical solution to be
sucked back into the water supply.
■
Before filling the container with solution, carry out a test
run with fresh water, and check all parts of the product
for leaks.
■
Make sure that the filler cap is properly closed after
filling.
■
Hang a tag on the product to note what chemical
solution is being used.
APPLICATION
■
Never blow through nozzles or other components by
mouth.
■
Avoid contact with chemicals. Immediately change
clothing that are contaminated with chemicals.
■
Do not aim the nozzle towards persons, animals, and
electrical equipment.
■
Do not spray where spark, flame, or other source of
ignition is present.
■
Do not operate the product in windy conditions. Always
aim downwind.
■
Avoid using the product in freezing weather since the
solution may freeze.
■
To reduce the risk of accidents and damage to the
product, never operate the product with:
●
flammable liquids
●
viscous or sticky liquids
●
caustic or corrosive chemicals
●
liquids above room temperature
■
Clean the product after each use.
The product may be subject to national requirements for
regular inspection by designated bodies, as provided for in
Directive
2009
/
127
/EC of the European Parliament and of
the Council of
21
October
2009
establishing a framework
for Community action to achieve the sustainable use of
pesticides.
ADDITIONAL BATTERY SAFETY WARNINGS
WARNING
To reduce the risk of
fi
re, personal injury, and product
damage due to a short circuit, never immerse your tool,
battery pack or charger in
fl
uid or allow
fl
uid to
fl
ow inside
them. Corrosive or conductive
fl
uids, such as seawater,
certain industrial chemicals, and bleach or bleach-
containing products, etc., can cause a short circuit.
■
Charge the battery pack in a location where the ambient
temperature is between 10°C and 38°C.
■
Store the battery pack in a location where the ambient
temperature is between 0°C and 40°C.
MAINTENANCE
■
Use only original manufacturer’s replacement parts,
accessories, and attachments. Failure to do so
can cause possible injury, can contribute to poor
performance, and may void your warranty.
■
Servicing requires extreme care and knowledge
and should be performed only by a qualified service
technician. Have the product serviced by an authorised
service centre only.
■
To avoid serious personal injury, always remove
the battery pack from the product when cleaning or
performing any maintenance.
■
After each use, check all parts of the product for leaks.
Return the product to an authorised service centre for
repair if necessary.
■
You may make adjustments or repairs that are
described in this manual. For other repairs, contact an
authorised service centre.
CLEANING THE REFILLABLE CONTAINER
■
Drain all chemical solutions from the refillable container
into a container approved for chemicals. Do not store
the chemicals in the refillable container.
■
Use clean water to clean and rinse the refillable
container. A small amount of mild household detergent
may be added. It may be necessary to rinse the
refillable container more than once.
CLEANING THE PRODUCT
■
Fill the tank about one-third full with clean water. A small
amount of mild household detergent may be added.
■
Do not use flammable solvents or abrasive cleaning
agents to clean the product.
■
Spray into a suitable container until the tank has been
emptied.
■
Refill and repeat the procedure with clean water. It may
be necessary to rinse the tank more than once, then
drain again as directed above.
■
Allow all parts to completely dry, then reinstall the tank cap.
■
Wipe the outside of the fogger with a clean, dry cloth.
DISPOSAL
■
Never dispose of residual chemicals or contaminated
rinsing solutions in waterways, drains, sewers, street
gutters, or manholes.
■
Dispose of residual chemicals, contaminated rinse
water, and used containers in accordance with local
waste disposal regulations.
TRANSPORTATION AND STORAGE
■
Ensure that all parts are clean and dry. Follow the
procedure described in this manual.
■
Stop the product and remove the battery pack before
storing or transporting.
■
For transportation, secure the product against
movement or falling to prevent injury to persons or
damage to the product.
■
Store the product in a cool, dry, and well-ventilated area
that is inaccessible to children. Keep the product away
from corrosive agents such as garden chemicals and
de-icing salts. Do not store the product outdoors.
Содержание RY18FGA
Страница 130: ...128 x 1 x 1 x 1 RY18FGA 0 ...
Страница 131: ...129 9 8 3 4 1 6 5 7 2 ...
Страница 132: ...H 2 O 1 2 5 2 1 1 6 130 ...
Страница 133: ...1 2 3 2 1 3 1 2 7 8 4 131 ...
Страница 134: ...p 137 p 133 p 134 132 ...
Страница 135: ...2 1 1 3 2 1 133 ...
Страница 136: ...2 1 1 1 2 2 3 H 2 O H2O 1 1 2 3 4 134 ...
Страница 137: ...1 2 3 4 2 1 1 1 2 1 2 H2O 3 4 5 H 2 O 7 5 6 135 ...
Страница 138: ...1 2 1 2 8 9 136 ...
Страница 139: ...20200529v1d6 1 2 1 1 1 3 2 137 ...
Страница 168: ...Techtronic Industries GmbH Max Eyth Straße 10 71364 Winnenden Germany 961087232 01 ...