background image

2

IMPORTANT SAFETY INSTRUCTIONS

The purpose of safety rules is to attract your
attention to possible dangers. The safety symbols
and the explanations with them, require your
careful attention and understanding. The safety
warnings do not by themselves eliminate any
danger. The instruction or warnings they give are
not substitutes for proper accident prevention
measures.

SAFETY ALERT SYMBOL.

Indicates

caution or warning. May be used in
conjunction with other symbols or
pictures.

Failure to obey a safety warning can result in
serious injury to yourself or to others. Always follow
the safety precautions to reduce the risk of fire,
electric shock and personal injury.

Do not attempt to operate this tool until you have
read thoroughly and completely understood the
safety rules, etc. contained in this manual. Failure
to comply can result in accidents involving fire,
electric shock or serious personal injury. Save this
Owners Operating Manual and review it frequently
for continual safe operation and for instructing
others who may use this tool.

APPLICATIONS

Air compressors are utilized in a variety of air
system applications. Match hoses, connectors, air
tools, and accessories to the capabilities of the air
compressor.

SPECIFIC SAFETY INSTRUCTIONS

WARNING.

If not used and maintained

correctly this compressor when used with
some pneumatic tools can cause serious

injury and death. Before attempting to operate this
machine, it is important that you read, understand
and follow these instructions very carefully. They
are designed for the safety of yourself and others
ensuring a long and trouble free service life from
your machine. If not used correctly and as detailed
in these instructions pneumatic tools can be
dangerous. This product can cause injury to the
operator and others.

The warnings and safety instructions must be
followed to ensure reasonable safety and efficiency
in using this product.

NOTE:

The operator is responsible for following the

warnings and safety instructions in this manual and
on the product.

Ensure that this compressor is disconnected from
the mains supply when not in use and the air
receiver fully discharged before servicing,
lubricating or making adjustments and when
changing accessories. Always switch ON and OFF
using the ON/OFF switch on the compressor
before switching OFF at the mains supply.

WARNING.

When spraying paint or

cleaning agents the fine mist produced
could ignite. When performing this type

of operation the compressor must be a minimum of
4 Metres away from the work area. Do not smoke
and keep naked flames and other sources of
ignition well away from the work area. Make sure
that the area in which you are working has good
ventilation and protect your nose and mouth with a
suitable face mask. Always check the safety data
sheets for substances being sprayed & ensure
manufacturers instructions are followed.

Protect yourself. Goggles will protect your eyes
from flying particles.

These compressors produce noise levels in excess
of 70dB(A). Persons working near the compressor
must be supplied with ear protection.

Drain tanks of moisture after each day’s use. If unit
will not be used for a while, it is best to leave drain
valve open until such time as it is to be used. This
will allow moisture to completely drain out and help
prevent corrosion on the inside of tanks.

This air compressor must be used in a suitable
environment. There must be adequate ventilation,
the ambient temperature must be +5/+40°C. The
working area must be free from dust, acid vapour,
explosive gasses and flammable materials.

Compressed air can be potentially dangerous when
not used correctly. Do not exceed the maximum
rated air pressure for the accessory. Do not direct
compressed air at yourself, any other person or
animals. Do not direct any liquid or any other
material that is being sprayed by yourself towards
any other person or animals.

Only use hoses and connectors designed for use
with compressed air. The maximum working
pressure of hoses and connectors must be higher
than the maximum working pressure of the com-
pressor. Do not attempt to move the compressor by
pulling on the air hose.

Содержание RC-3100B

Страница 1: ... enjoy years of safe reliable service SPECIFICATIONS Voltage 230V 50Hz R Intermittent duty S3 75 ated power 2 2kW 3 0HP Receiver capacity 100l Type Oil lubricated Free air delivery FAD 365l min Oil type SAE 30 Oil capacity 500ml CFM 12 9 Working pressure 10bar 145psi No load speed 1375min 1 Sound pressure level LpA71 5dB A k 3dB A Sound power level LWA91 5dB A k 3dB A Net weight 59 2kg THANK YOU F...

Страница 2: ...gs and safety instructions in this manual and on the product Ensure that this compressor is disconnected from the mains supply when not in use and the air receiver fully discharged before servicing lubricating or making adjustments and when changing accessories Always switch ON and OFF using the ON OFF switch on the compressor before switching OFF at the mains supply WARNING When spraying paint or...

Страница 3: ...fe Never weld or drill holes in the air tanks Only use recommended parts To avoid the risk of bursting only hoses with a rated pressure of 10 bar or more should be used Never attempt to re pair faulty hoses Avoid kinking or trapping the air hose Always replace faulty hoses never attempt a repair if a leak is detected Make sure the hose is free of obstructions or snags Entangled or snarled hoses ca...

Страница 4: ... with ANSI Z87 1 c Additional safety protection will be required in some environments For example the working area may include exposure to a noise level which can lead to hearing damage The employer and user must ensure that any necessary hearing protection is provided and used by the operator and others in the work area Some environments will require the use of head protection equipment When requ...

Страница 5: ...ct is powered by a precision built electric motor It should be connected to a power supply that is 230 V AC only normal household current 50 Hz Do not operate this product on direct current DC A substantial voltage drop will cause a loss of power and the motor will overheat If the product does not operate when plugged into an outlet double check the power supply GROUNDING INSTRUCTIONS This product...

Страница 6: ... regulated 5 Transportation handle 6 Air outlet pressure gauge 7 Air receiver pressure gauge 8 Rubber foot x 2 9 Wheel x 2 10 Drain valve 11 Air receiver tank 12 Oil drain plug 13 Dipstick 14 Air filter 15 Safety valve 16 Air outlet pressure regulator lock ring DESCRIPTION 11 2 3 8 9 4 6 7 5 14 13 10 1 12 15 16 ...

Страница 7: ...TS Belt driven compressor Wheels x 2 Wheel fixings bolt nut x 2 Rubber foot x 2 Rubber foot fixings bolt nut x 2 Dipstick Operator s Manual WARNING If any parts are damaged or missing do not operate this product until the parts are replaced Use of this product with damaged or missing parts could result in serious personal injury WARNING Do not connect to power supply until assembly is complete Fai...

Страница 8: ...ease all tank air pressure before removing the dipstick Be sure the air vent in dipstick Fig 3 is free from debris If air vent is blocked pressure can build in crankcase causing damage to the compressor and possible personal injury Remove the dipstick by twisting it upwards by hand Fill the compressor pump with an air compressor oil such as SAE 30 non detergent API CG CD Heavy Duty oil at slow int...

Страница 9: ... used play an important role in the operation of this product Wiring intended for lights cannot properly carry an air compressor motor and wire that is heavy enough for a short distance may be insufficient for a greater distance Before using this product verify your receptacle is wired appropriately for air compressor use and the length and gauge of any extension cord used is sufficient to carry t...

Страница 10: ...ion pressed in Fig 6 Check that the air outlet pressure regulator is closed Fig 7 Check that the drain valve is closed Fig 8 Connect the compressor to a suitable 16A mains supply Switch on the compressor by pulling up the On Off switch Fig 9 The compressor will now start When the air receiver tank is pressurised to its working capacity the compressor will automatically switch off When the compress...

Страница 11: ...at the same time observing the air outlet pressure gauge until the pressure gauge reads the minimum pressure for the accessory Fine adjustments to the air pressure can be made until the accessory is working at its optimum performance When the correct operating air pressure has been set the air outlet pressure regulator can be locked by tightening the locking ring Fig 12 Do not exceed the maximum r...

Страница 12: ...ondensation Carefully undo the drain valve nut anti clockwise until you hear a hissing noise this is the reservoir depressurising Fig 15 When the gauge indicates zero and the hissing has stopped tighten the drain valve nut again OIL CHANGING Replace the oil after the first 100 hours of operation and every 300 hours subsequently Remember to check the oil level at regular intervals For changing the ...

Страница 13: ...emove the securing bolt and pull the filter from the compressor Fig 16 Unclip the front and rear of the filter and pull out the filter element Fig 17 Clean the filter using a soft brush If necessary the filter can be carefully cleaned in warm soapy water Rinse and let the filter dry completely before refitting If the filter or filter element is damaged you must replace it Reassemble the filter and...

Страница 14: ... it is advisable to give the compressor a thorough clean This should include the removal of all fitted accessories Do not use any solvents as these can damage plastic parts Only use a clean cloth dampened with warm soapy water Any metal parts should be given a wipe with a light machine oil to prevent rusting WARNING Do not at any time let brake fluids gasoline petroleum based products penetrating ...

Страница 15: ...ghten if necessary Switch off and wait approx 5 minutes Press the reset button and switch on again Contact your nearest service agent Return the machine to your nearest service agent Open drain valve to expel air Compressor should start again when pressure reduces Drain receiver completely of air Remove the valve end plug Carefully clean the valve seat and the gasket Reassemble Replace regulator R...

Страница 16: ...rdous Voltage Disconnect from power source before servicing Do not use in damp conditions Hot Surface To reduce the risk of injury or damage avoid contact with any hot surface Enclosure Alert Do not operate the portable compressor with the doors or enclosure open Unexpected Starting The compressor may start without warning Recycle Symbol Waste electrical products should not be disposed of with hou...

Страница 17: ...17 NOTES ...

Страница 18: ...18 NOTES ...

Страница 19: ...19 NOTES ...

Страница 20: ......

Отзывы: