Avoid heavy impact to or falling down of the 

measuring tool. 

After severe exterior effects to the 

measuring tool, it is recommended to carry out an 

accuracy check each time before continuing to work. 

SWITCHING ON AND OFF 

To 

switch on

 the measuring tool, press the measuring/on 

button (1) for a few seconds. 

When switching on the measuring tool, the laser beam is 

also switched on. 

To 

switch off 

the measuring tool, press the off/memory 

clear button (2) for a few seconds. 

If none of the buttons are pressed for approx. 3 minutes, 

the measuring tool is switched off automatically in order to 

extend the service life of the battery.

WARNING! Do not point the laser beam at persons or 

animals and do not look into the laser beam yourself, 

not even from a large distance. 

SINGLE LENGTH MEASUREMENT (Fig. 1, 2)

 1. Press measuring/on button to activate the laser, and aim 

at the object which is to be measured.

 2. Press measuring/on button again to take measurement. 

The measured value is indicated at the bottom in the 

display (3). 

 3. Press the measuring/on button again to take a second 

measurement. The second length is shown in the lowest 

row of the display.

The measured value typically appears after 0.4 seconds 

and at the latest after 3 seconds. The duration of the 

measurement depends on the distance, the light conditions 

and the reflection properties of the target surface. The end 

of the measurement is indicated by a signal tone. The laser 

beam is switched off automatically upon completion of the 

measurement. 
When no measurement has taken place approx. 30 

seconds after sighting, the laser beam is switched off 

automatically to save the batteries. 

CONTINUOUS/TRACKING MEASUREMENT (Fig. 3) 

For continuous/tracking measurements, the measuring tool 

can be moved relative to the target, whereby the measuring 

value is updated approx. every 0.4 seconds. In this manner, 

as an example, you can move a certain distance away from 

a wall, while the actual distance can always be read. To 

start continuous measurements, push measuring/on button 

for a few second. 
To stop continuous measurement, press off/clear button . 

Pres measuring/on buttonit to exit and return to the single 

length measurement mode. 

HOLD FUNCTION

While continuous measurement is in process, press the 

measuring/on button to hold the measurement process, 

and the current measuring value is displayed on the 

display, but is no longer continuously updated.

DISPLAY BACKLIT

When switching on the measuring tool, the display backlit 

is also switched on. The indications on the display is clearly 

visible even in dark situation.

If none of the measuring tool button are pressed for approx. 

30 seconds, the backlit will be turned off automatically. 

Press any button to turn it on again.

WORKING ADVICE GENERAL INFORMATION 

The reception lens (7) and the laser beam outlet (6) 

must not be covered when taking a measurement. 

The measuring tool must not be moved while taking a 

measure¬ment (with the exception of the continuous 

measurement function). Therefore, place the measuring 

tool, as far as this is possible, against or on the measuring 

points. Measurement takes place at the centre of the laser 

beam, even when target surfaces are sighted at an incline. 

INFLUENCE EFFECTS ON THE MEASURING RANGE 

The measuring range depends upon the light conditions 

and the reflection properties of the target surface. For 

improved visibility of the laser beam when working outdoors 

and when the sunlight is intense, use the laser viewing 

glasses (accessory) and the laser target plate (accessory), 

or shade off the target surface. 

INFLUENCE EFFECTS ON THE MEASURING RESULT 

Due to physical effects, faulty measurements cannot be 

excluded when measuring on different surfaces. Included 

here are: 

.  transparent surfaces (e.g., glass, water), 

.  reflecting surfaces (e.g., polished metal, glass), 

.  porous surfaces (e.g. insulation materials), 

.  structured surfaces (e.g., roughcast, natural stone). 
If required, use the laser target plate (accessory) on these 

surfaces. 
Also, air layers with varying temperatures or indirectly 

received reflections can affect the measured value. 

ERROR CODE

Message code 

Possible Cause

Remedy

204

Calculation error

Read instruction and 

measure again

208

 Input current too high Contact your dealer

220

Battery too low

Replace batteries

252

Temperature too high

O p e r a t e  i n  o p t i m u m 

temperature (-10°~ +40°)

253

Temperature too low

O p e r a t e  i n  o p t i m u m 

temperature (-10°~ +40°)

255

Received laser light too 

weak, 

change to another target 

or cover the target with a 

piece of white paper.

or over time 

256

Received laser light too 

intense

change to another target 

or cover the target with a 

piece of white paper.

261

Out of range

Measure target within 

the range (0.15~20m)

500

Hardware defective

Power off the measuring 

tool and re-start. If it is 

still not workable, please 

contact your dealer.

  

    

    

 

 

  

 