![RYNO WORX RY10MA Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/ryno-worx/ry10ma/ry10ma_owners-manual_1503628024.webp)
Operations Guide
Part 2
– Agitating and Monitoring Temperature
1. Never leave the melter unattended while the torch is lit. If flame goes out, promptly turn off the flow of gas;
double check that the melter is free and clear of any gas odors before attempting to re-ignite the torch.
2. While your melter is ignited you should continuously be monitoring the material temperature. Check with
crack sealant manufacturer for safe melting temperatures and ensure you continually adjust your regulator
to maintain the recommended temperature range. If the material becomes too hot, you may need to turn off
your torch periodically.
3. As material begins to melt, it’s important to consistently agitate. Agitation moves the solid crack sealant
along the bottom and prevents ‘hot spots’ from forming which can alter the effectiveness of the sealant
after it is applied. Agitation also prevents chunks of over-heated material from forming which will eventually
plug or block your flow valve which can slow down the application process.
Part 3
– Applying Crack Filler to Pavement
Once you have effectively liquefied the crack sealant, you may begin applying it. For best results, the surface
should be clean and free of dirt, debris and vegetation. Ensure shoe is lowered and resting on the pavement.
Push melter into position, aligning the crack you wish to fill with the center of the shoe. Slowly squeeze the
valve control arm until crack filler begins to come out of the valve and onto the crack. Slowly push the melter
forward, keeping the crack aligned with the center of the shoe. Increase speed of the material flow by
squeezing harder on the valve control arm. If material flow slows, check to ensure that you have enough
melted material in the kettle and agitate to keep the flow tube clear.
Part 4
– Turning Off and Draining
Once you have finished using the melter, make sure it is fully drained and no crack filler remains inside the
kettle or the flow valve. Leaving the flow valve empty after use will prevent the valve from being blocked the
next time you use the melter.
23
Содержание RY10MA
Страница 1: ...Ryno Worx RY10MA Owner s Manual 10 Gallon Direct Fire Melter Applicator Torch Model...
Страница 7: ...Part Part Number Agitation Upgrade Kit Agitation Upgrade Kit 6...
Страница 8: ...Part Part Number Thermometer Guard Upgrade Kit Thermometer Guard Upgrade Kit 7...
Страница 16: ...Install the handle on the melter lid with M8 washers and locknuts as shown 15...
Страница 18: ...channel at the bottom of the melter Fully insert the torch hook into the 17...