1. Press “D” 3x to enter programming mode

2. Press “C” to change. System beeps corresponding to the numbers shown.

3. Press “C” to change again or “D” to exit

It is essential that the Tow and Door directions be set to allow for correct operation

It is highly recommended that whenever the alarm is armed that the rear caravan legs are in the down position as this

provides additional stability and assists in reducing false alarms.

Sensor Battery Replacement

Each sensor has an expected battery lifetime of between 12 and 24 months under standard operating conditions. When a
low battery condition if reached the sensor will flash every 10 seconds indicating that it is time to replace the battery. 
Please note that high use (ie living in van / constant operation) situations will shorten the life of the battery and will 
require more frequent changes.

Warranty

The statutory warranty period applies. If the product is defective please contact the retailer that you purchased it from 
for initial assessment and to process the RMA claim. 
For any repair and guarantee processing, the following items are required:
1/ Defect component(s) must be returned to the manufacturer via the place of purchase

2/ Copy of receipt with purchase date
3/ Reason for claim or description of the fault
4/ Contact details of claimant
The manufacturer will at its sole discretion repair, replace or refund if it is agreed that the purchased item or sub-
component part is faulty. The manufacturer is not liable for any additional costs involved in the return of the 
product(s) nor is it liable for any damages or compensation.

Liability

1/ tech7/RVsecure accepts no liability for damage done either to the unit itself, its sub components or to the vehicle due to owners
incorrect wiring. If in doubt please consult a professional.
2/ tech7/RVsecure accepts no liability for any theft of any property, vehicle or other. 
3/ tech7/RVsecure accepts no liability for any damage to any property, vehicle or other due to the operation of the braking circuit (if
connected) at any time or under any condition. 

Maintenance

Any alarm system requires ongoing testing and maintenance to ensure that it is in top operating condition and to 
reduce the chances of false alarm.  We recommend the following maintenance schedule:

Monthly

Check sensors and control unit physically OK with visual inspection. Check sensors for any flashing indication of low 
battery. Ensure there is no evidence of cobwebs around the sensors. 

Annually

Full alarm test including activation of all zones
PIRs – walk test to ensure correct operation. Remove cover of PIR to ensure no ingress by any insects, fluids etc.  