Victrix 24kW X Instructions 

 

Introduction 

Boiler Operating Instructions 

The Victrix 24kW X boiler is a condensing wall hung, room sealed boiler.  This boiler has the highest efficiency 
possible for a gas boiler,  ie 4 stars (****) in conformity with European Directive 92/42 EEC. 
The boiler provides central heating and may also provide priority heating of the domestic hot water supply if 
the optional  3 way valve kit is used (RVR Stock No: ACB515). It is designed for use with a fully pumped, 
sealed and pressurised heating system using Natural Gas or LPG.  The boiler is supplied for use with one of 
these gas types and must be converted before it can be used on another gas.  A boiler equipped for natural 
gas must not be used on LPG or vice versa. 
 
The boiler is supplied with a pump,  automatic bypass, pressure relief valve, expansion vessel and pressure 
gauge fully assembled and tested. 
As supplied, the boiler will automatically modulate to provide central heating outputs between 4.7 and 
26 kW .  

IMPORTANT 

All gas appliances must be installed by a competent and qualified person, in accordance with relevant clauses 
of applicable standards and recommendations.  These include but may not be limited to the following:- 
I.S. 813 Domestic Gas Installations 
I.S, 820 Non-Domestic Gas Installations 
All relevant Building Regulations. 
Local Water Bye Laws 
IEE Wiring Regulations 
Health & Safety legislation 
 
This appliance meets the requirements of IPX4D, ie degree of protection against moisture. 
Failure to install this appliance correctly could lead to prosecution. It is in your own interest and that of safety 
to ensure that the law is complied with.  Manufacturer's instructions must 

NOT 

be taken in anyway as over-

riding statutory obligations. 

1. Boiler status indicator display 
2. Main Switch OFF-DHW - DHW/Central 
 

heating 

3. Domestic hot water temperature selector 
4. Central Heating temperature selector 
5. Pressure Guage

 

Using the Boiler 

Before lighting, make sure  that the system is full of  water and that the pressure guage (5) indicates a pres-
sure of 1 - 1.2 bar. 
-Open the gas valve on the gas supply to the boiler. 
-Turn main selector (2) to Domestic Hot Water             or Domestic Hot Water and Heating  

N.B. 

With the switch (2) set to             the 

Central Heating temperature selector

(4) is disabled, the domestic hot 

water temperature is regulated by selector (3): the display shows the Summer symbol      .  With the selector 
set to             the 

Central Heating temperature selector 

(4) is used to regulate the temperature of radiators while 

selector (3) continues to be used for domestic hot water; the display shows the Winter symbol 
Turn the selectors clockwise to raise the temperature, anticlockwise to lower it. Boiler operation is now  
automatic.  

Содержание VICTRIX 24kW X

Страница 1: ...ority For Technical assistance spare parts or service call RVR Energy Technology Limited Kenmare Co Kerry Tel 064 41344 Fax 064 89520 Doc Ref ALT107 181207 Read these instructions completely before us...

Страница 2: ...I S 820 Non Domestic Gas Installations All relevant Building Regulations Local Water Bye Laws IEE Wiring Regulations Health Safety legislation This appliance meets the requirements of IPX4D ie degree...

Страница 3: ...Immergas 80 litre T 30 C in accordance with EN 625 1 min 20 2 Specific range D UB Immergas 105 litre T 30 C in accordance with EN 625 1 min 22 0 Specific range D UB Immergas 120 litre T 30 C in accord...

Страница 4: ...uctions Dimensions Victrix 24kW X Key V Electrical connection G Gas supply RU Cylinder return optional MU Cylinder flow optional RR System filling SC Condensate drain min internal diameter 13mm R Syst...

Страница 5: ...ectrode 21 Safety thermostat 4 Gas valve 13 Air intake pipe 22 Air valve 5 Voltage transformer 14 Negative signal pressure point 23 Boiler circulating pump 6 Fan 15 Positive signal pressure point 24 S...

Страница 6: ...heating tank and connected to terminals 36 and 37 If this cable is routed in close proximity to cables carry ing mains voltages then screened cable should be used The resistor connected to terminals...

Страница 7: ...with the round protrusions facing downwards in con tact with boiler flange and tighten using the screws supplied with the kit Fit the male end smooth of the adapter 3 in the female end of the concent...

Страница 8: ...he fe male end of the flanges 3 4 Fit the male end of the intake terminal 6 up to the stop on the female end of the bend 5 making sure that the relevant internal and external sealing rings are fitted...

Страница 9: ...g tables The resistance factor varies depending on whether the component in question conveys fresh inlet air or hot combustion gases All boilers have a maximum resistance factor of 100 The sum of all...

Страница 10: ...nces Component Resistance Quantity Total 80mm Intake pipe 0 87 9 7 83 90 air intake bend 1 9 3 5 7 80mm Flue pipe 1 2 6 7 2 90 Flue bend 2 6 2 5 2 25 93 Total Flue Resistance In this case the total re...

Страница 11: ...terminal is fitted within 850 mm of a plastic or painted gutter or 450 mm of painted eaves or 300 mm of a plastic car port roof an aluminium shield at least 1 m long should be fitted to the underside...

Страница 12: ...iler may be installed in any room or internal space although particular attention is drawn to the re quirements of the current IEE Wiring Regulations Where a room sealed boiler is installed in a room...

Страница 13: ...orporated into the boiler is pre charged to 1 0 bar and is suitable for a sealed heating system with a maximum water content of 80 litres 18 gal Above 80 litres consideration should be given to fittin...

Страница 14: ...to heat the hot water tank adequately The hot water only position on the boiler is not in use for this configuration Filling the central heating system The system design pressure cold should be set to...

Страница 15: ...appliance with wet hands or other parts of the body and never touch when barefoot never pull electrical cables or leave the appliance exposed to atmospheric agents rain sunlight etc the appliance pow...

Страница 16: ...cleaning function symbol Malfunction symbol combined with error code Flame present symbol Burner output scale symbol Fault and anomaly signalling The Victrix 24 kW boiler indicates any malfunctions us...

Страница 17: ...valve No pressure variation must occur in the next five minutes on the gauge Ensure activation of the device for protection against the ionisation flame control gas activation time must be less than...

Страница 18: ...Page 18 Victrix 24kW X Instructions Variable Heat Output Victrix 24kW X...

Страница 19: ...Page 19 Victrix 24kW X Instructions Victrix 24kW X Wiring Diagram...