Boiler Location
The boiler is not suitable for external installation.
The boiler must be installed on a flat vertical wall which is capable of supporting the weight of the boiler.
The boiler can be fitted to or adjacent to a wall comprising of a combustible material without the need for a
special thermal insulation barrier.
The boiler may be installed in any room or internal space, although particular attention is drawn to the re-
quirements of the current IEE Wiring Regulations. Where a room sealed boiler is installed in a room con-
taining a bath or shower, it must not be possible for a person using the bath or shower to touch any electri-
cal switch or boiler control utilising mains electricity.
The boiler may be installed in a cupboard or compartment, provided it is correctly designed for that pur-
pose.
NB: Adequate clearances are required to allow servicing of the boiler. Please see page 3.