8.5
Checking the function of the degasification valve
DANGER
Evolution of flammable gases
On finishing vacuum operations, always store or place the
wet separator in a well-ventilated area, since depending
on the material being vacuumed up, hydrogen gas can
be evolved.
Use a suitable sealing liquid that does not promote the
evolution of flammable gases / foam or chemical reactions.
Before using the wet separator, always check the
degasification valve for correct operation.
1. Push down the valve disc with light pressure.
2. Check that the valve head automatically returns to its original
position under spring force.