Control Unit Installation
The Control unit should be installed as close as possible to the batteries to minimise
the length of the main battery leads, at the same time the unit should be protected
from battery fumes from vented batteries.
Ensure adequate ventilation is provided to allow efficient heat dissipation via the
control unit vents. These vents must not be covered or obstructed.
The unit is not weatherproof & therefore must be suitably protected.
Mount the unit securely to a wall or other vertical surface, using the mounting holes
provided (hole centres are 270mm W x 200mm H), in a suitable location allowing
for cable entries in the base of the unit. The cable entries are fitted with blanking
grommets which need to be pierced or can be removed for attachment of 20mm
conduit fittings if required.