background image

5

fig 5

fig 6

fig 3

fig 4

INITIAL

MOUNTING

SCREW

WIRING

HOLE

SECONDARY

MOUNTING

SCREW

GREEN

BLACK

RED

YELLOW

WIRE RUNS THROUGH

OPENING AND

INTO WIRING HOLE

6. INSTALLATION

To complete the installation the installer must supply the following:

• RJ31X/CA38A disconnect and bypass jack. This will provide a bypass

capability whereby the telephone line continues to work if the DTI-1
needs to be removed from the telephone line. Note: If installation is
done at a location that has an existing alarm jack (RJ31X/CA38A)
then ensure that the alarm is installed before the DTI-1 RJ31X/CA38A
jack. Otherwise, the alarm system may not have disconnect priority.

• Two plastic wall anchors to mount the TDB-2 door speaker unit near

a point of entry.

Figure 1 shows the detail of the connectors located on the front of the
unit. Figure 2 shows interconnection of the DTI-1 with other parts that
form the system.
Installation of the system requires that the installer install a 4-conductor
wire (24 AWG) be installed from the location of the door speaker unit to
the location of the system control unit. It is recommended that the system
control unit be installed near the point-of-entry of the customer's main
telephone line. Please ensure that adequate AC power is available in the
general vicinity.

1. First drive an initial mounting screw 2” above the doorbell wiring

hole leaving about a 1/4” of screw shaft exetending from wall.

2. Thread wire throughopening at bottom of unit.

NOTE: We recommend that you use a silicon sealer to protect the
wiring around the wiring hole.

3. Hang TDB-2 on initial mounting screw as shown in figure 3.
4. Secure TDB-2 to wall with a secondary mounting screw as shown in

figure 4.

5. Connect the four wires to the wiring posts of the TDB-2 as shown in

figure 5.

6. Replace the cover as shown in figure 6.

GREEN

BLACK

RED

YELLOW

Содержание DTI-1

Страница 1: ...DTI 1 Instruction Manual Doorbell Telephone Interface T elephone Ring On Off Remote Trigger T ele DoorBell T elephone Line In Out Power Plug 16V AC 2 1 ...

Страница 2: ...ther appliances including amplifiers that produce heat 10 Power Sources The appliance should be connected to a power sup ply only of the type described in the operating instructions or as marked on the appliance 11 Grounding or Polarization The precautions that should be taken so that the grounding or polarization means of an appliance is not defeated 12 Power Cord Protection Power supply cords sh...

Страница 3: ... from any installed tele phone set including cordless Unmatched in convenience this unique new product provides the following features 1 System will work as a replacement or in parallel with any standard doorbell 2 Supports speakerphone quality conversation between the telephone and the door speaker 3 Unique telephone ringing when door speaker button is depressed 4 Allows homeowner to activate the...

Страница 4: ...ill provide greater ringing power to the telephones Can also use a 16 24 VDC supply Note Do not exceed 24VDC or serious damage can occur to the controller unit CAUTION For added protection we strongly recommend you use surge protectors on both your power supply and on the C O line phone line to protect against lightning and other energy surges 1 2 3 4 5 6 fig 1 T elephone Ring On Off Remote Trigge...

Страница 5: ...e 2 shows interconnection of the DTI 1 with other parts that form the system Installation of the system requires that the installer install a 4 conductor wire 24 AWG be installed from the location of the door speaker unit to the location of the system control unit It is recommended that the system control unit be installed near the point of entry of the customer s main telephone line Please ensure...

Страница 6: ...d on your telephone This will connect you to the door speaker NOTE Using can be done at times when no one has depressed the door speaker button and provides the user with a monitor function 3 The DTI 1 provides a six second contact closure when the door button is depressed or when the telephone line rings This provides a mute function if connected to Russound Multi Zone controller with mute capabi...

Страница 7: ... speaker button is pressed You have a dial tone feedback at the speaker when door speaker button is pressed When pressing for monitoring the door you get an operator recording eg this is an invalid number and you have no communication to the speaker On a gate installation you have no audio communication to the speaker Telephone does not ring when door button is pressed 10 TECHTIPS When the DTI 1 s...

Страница 8: ...5 Forbes Rd Newmarket NH 03857 USA 603 659 5170 Fax 603 659 5388 e mail tech russound com Come visit us at 062501 ...

Отзывы: