![Russell Hobbs RHDW1 Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/russell-hobbs/rhdw1/rhdw1_service-manual_1500893061.webp)
From the component :
Probes of the tester should be applied on to the related connectors as shown on the
pictures
Pressure switch
:
From the electronical card:
∞
Ω
THERE
İ
S WATER
CN2.10 – CN2.2
0
Ω
THERE ISN’T WATER
Above sketch show the connectors of the pressure switch on the electronical card.
Probes of the tester should be applied on to the related connectors.
From the component
:
Probes of the tester should be applied on to the related
connectors as shown on the pictures
ELECTRON
İ
CAL CARD
CONNECTORS
O
R
A
N
G
E
B
R
O
W
N
CONNECTORS SHOULD BE MEASURED
58
Содержание RHDW1
Страница 1: ...DISHWASHER SERVICE MANUAL ...
Страница 11: ...Name Plate 9 ...
Страница 22: ...Front panel Remove six screws that fix the front panel ...
Страница 25: ...22 ...
Страница 27: ...1 6 Control Panel a Remove six screws that fix control panlel to the door inside sheet iron 24 ...